{"product_id":"2-ton-13-4-seer2-80-afue-60-000-btu-gas-furnace-and-r32-air-conditioner-system-upflow-3","title":"GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9T800603BN","description":"\u003ch2\u003e\u003cspan\u003eGOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9T800603BN\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe ACiQ AQ-GLXS3BN2410 is a durable, high-quality condenser unit that is the perfect cooling solution for homes up to 1400 square feet in northern states. At a capacity of 2 tons and a SEER2 rating of 13.4, this cooling-only condenser won’t break the bank while still reliably cooling your home for years to come. Easy to access service valves make installation by a licensed HVAC professional a breeze. Pay for high-end performance without the high-end price tag when you choose ACiQ.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e13.4 SEER2, 2 tons AC-only Condenser: With a 13.4 SEER2 efficiency rating and a tonnage of 2, this AC condenser is a great choice for smaller homes that experience shorter, milder summers.\u003c\/li\u003e\n\u003cli\u003eSingle Stage: When properly sized and installed, a single stage condenser is a cost-effective and durable option to cool your home.\u003c\/li\u003e\n\u003cli\u003eR32 Refrigerant: With R32 refrigerant, this unit complies with Clean Air Act refrigerant requirements.\u003c\/li\u003e\n\u003cli\u003eFully Charged for up to 15' of Line Set: The condenser comes fully pre-charged with enough refrigerant for up to 15 feet of line set.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-GLXS3B-specsheet_1_fcc0ec8e-4d70-4fc9-9847-8be2330d53d2.pdf?v=1779259934\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eGLXS3B Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-R32-AirConditioner-Install-Manual_1_a0155cd7-4456-4498-b2ad-594691928e12.pdf?v=1779259933\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eInstallation Manual\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-GLXS3B-warranty_1.pdf?v=1779260205\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eWarranty Information\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/CAPFA-CAPTA-CHPTA-R32-Spec-Sheet_a2f84f22-9809-48e3-ab24-2dfb27d81709.pdf?v=1779260359\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCAPFA Specifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GR9T80_Specification_Sheet_0276daaa-519e-4d8f-ab1a-3bb5b8576103.pdf?v=1779695185\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eGR9T80 Specifications Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/GR9T80_GD9T80-Install-Manual_7b061655-d412-45e2-ac7a-f31c7f4819b5.pdf?v=1779695187\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eGR9T80 Installation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReliable All-Season Comfort System:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Combines a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-ton R32 air conditioner\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60,000 BTU Goodman gas furnace\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, delivering consistent heating and cooling for compact residential spaces.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eEfficient Cooling Performance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e13.4 SEER2 rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides dependable energy efficiency for everyday cooling needs without unnecessary complexity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStrong Heating Output for Size:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60,000 BTU, 80% AFUE furnace\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e offers robust heating capacity, making it suitable for colder environments or higher demand homes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eModern R32 Refrigerant Technology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eR32 refrigerant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, improving efficiency potential while reducing environmental impact compared to older refrigerants.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUpflow Installation Ready:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003evertical airflow (upflow) setups\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, ideal for basements, closets, utility rooms, and standard HVAC configurations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDurable Goodman Engineering:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built for long-term reliability, straightforward servicing, and consistent seasonal performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eValue-Oriented Performance System:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Focuses on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estrong heating capability and dependable cooling at a competitive price point\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What size home is this Goodman 2 Ton HVAC system best suited for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: A 2-ton system is typically designed for small to medium homes, depending on insulation, climate, and layout. Proper Manual J load calculation is recommended for accurate sizing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What efficiency ratings does this system offer?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: This system combines a 13.4 SEER2 R-32 air conditioner with an 80% AFUE gas furnace, delivering balanced cooling efficiency and standard gas heating performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the furnace heating capacity?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The furnace is rated at 60,000 BTU input, producing about 48,000 BTU of usable heat at 80% efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Does this system use R-32 refrigerant?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. The outdoor condenser uses R-32 refrigerant, a modern low-GWP refrigerant designed for improved environmental performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is this system compatible with upflow installation?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. The GR9T800603BN furnace supports upflow and horizontal installation, making it flexible for basements, closets, and utility spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What blower motor does it use?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It includes a 9-speed ECM blower motor that improves airflow control, efficiency, and quieter operation compared to standard motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Can this furnace be converted to propane (LP)?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. It ships configured for natural gas but can be converted to propane using an optional conversion kit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: Why choose a Goodman HVAC system?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Goodman systems are widely used for their value-focused pricing, simple serviceability, and readily available replacement parts when properly installed and sized.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eReplace or clean air filter every 1–3 months to maintain airflow, efficiency, and indoor air quality.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eKeep outdoor condenser unit clear of debris and maintain at least 2 feet of clearance for proper airflow.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSchedule professional HVAC maintenance twice yearly—before cooling and heating seasons.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInspect and clean supply and return vents regularly to ensure balanced airflow and comfort.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCheck condensate drain line periodically to prevent clogs, leaks, and water damage.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify thermostat operation and settings for accurate temperature control and energy savings.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMonitor for unusual noises, odors, or performance changes and address issues early.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHave a licensed technician inspect burners, heat exchanger, venting, and safety controls annually.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnsure refrigerant charge and electrical components are checked for optimal system performance.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eImprove home insulation and seal air leaks to reduce system strain and boost efficiency.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":45676654428351,"sku":"AQ-GLXS3BN2410 \/ AQ-CAPFA2422B3 \/ AQ-GR9T800603BN","price":2959.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/aciq_stdcondenser_capta_80upflow_800x800-logo_3_eb56e49c-0522-44ec-9f3f-2a31ebc038e4.webp?v=1780388006","url":"https:\/\/backyardprovider.com\/products\/2-ton-13-4-seer2-80-afue-60-000-btu-gas-furnace-and-r32-air-conditioner-system-upflow-3","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}