Skip to product information
1 of 10

Aims Power

Aims Power 10000 Watt Pure Sine Inverter Charger - PICOGLF10KW48V240VS

Aims Power 10000 Watt Pure Sine Inverter Charger - PICOGLF10KW48V240VS

review stars 1 Review

5% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $3,761.00 Sale price $3,572.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$28.99

$70.00

$66.99

Add-Ons Bundle

$30.00

$28.99

$70.00

$66.99

Bundle Offer

$100.00

$95.98

Recently Viewed

Aims Power 10000 Watt Pure Sine Inverter Charger - PICOGLF10KW48V240VS

This inverter will output 120 or 220/230/240Vac, and it can output 50 or 60Hz via the SW4 switch on the DC side of the product. This means that this inverter works internationally and is operable with nearly any electrical system on the planet!

Built with a 48 volt DC input, this inverter performs with very little power loss. Users receive a notable increase in efficiency in large systems when compared to using 12 or 24 volts, which can be an attractive feature for sustainability lovers looking to live as efficiently as possible.

The most common use for this inverter is emergency backup power in homes, business and recreation locations. You’ll always be prepared for the next power outage with access to 10000 watts of continuous power and 30,000 watts of surge (for up to 20 seconds).

However, we recommend recharging your battery bank with — a cleaner form of power.

Make a step in the right direction when it comes to preserving this beautiful planet by choosing an inverter powered by renewable energy when building your next electrical system.

This monster of an inverter can pretty much get any job done imaginable.

The development of this new DC-to-AC inverter technology combined with the existing environmental benefits of renewable energy usage puts this product in high demand among AIMS Power customers.

One of the most sought-after features this inverter has is the direct-connect terminal block, which allows users to surpass the 10000 watt capacity and harness its 300% surge power (up to 30,000 watts for 20 seconds as previously stated).

AIMS Power also has aif you’re looking for something with a few less features and a lower price. We’re constantly reinventing our products so that users are provided with the best technology available on the market.

When you purchase a low frequency inverter charger from AIMS Power, you’re getting our top-of-the-line product offering. The unit is repairable, and we stand behind it with a free one-year warranty and tech support.

Have a hunting cabin or off-grid vacation home? This AIMS Power inverter is perfect for supplying reliable electricity to the entire house.

It’s also built to withstand reasonable heat and temperature fluctuations because of its over-temperature protection and dual thermally-controlled fans.  And it’s protected from humidity or dust and dirt by virtue of its marine-coated or “conformal-coated” boards. This inverter provides the reliability needed in any business or residential emergency backup power applications.

If you need an identical inverter with a bit more power, try our

Features
  • 10000 watt low frequency inverter 110/220Vac Split Phase
  • 30000 watt surge for 20 seconds -3x surge capability
  • Battery Priority Selector
  • Terminal Block
  • Marine Coated and Protected
  • Multi Stage Smart charger 100 Amp charges GEL, Lead, AGM, Lithium
  • Remote panel available
  • 10msec typical transfer time
  • Selectable 25W power save mode (hibernation)
  • 8 battery charger settings
  • Automatic transfer switch
Specifications
  • Continuous Output Power: 10000 Watts
  • Surge Rating: 30000 Watts (20 Seconds)
  • Output Waveform: Pure Sine/Same as input (Bypass Mode)
  • 100-110-120Vac / 220-230-240Vac
  • Nominal Efficiency: >88% (Peak)
  • Line Mode Efficiency: >95%
  • Output Frequency: 50Hz +/- 0.3Hz / 60Hz +/- 0.3Hz
  • Typical Transfer Time: 10ms (Max)
  • THD: < 10% DC
  • Ambient operating temperature: 14°F to 122°F (-10°C to 50°C)
What our Experts Think  
  • Massive 10,000W pure sine wave output delivers industrial-grade power for whole-home backup, workshops, and off-grid systems.
  • 48V DC architecture improves efficiency by reducing current draw, heat, and cable losses in large battery bank installations.
  • Integrated inverter + charger design supports seamless hybrid setups with grid or generator input for continuous power availability.
  • 240V AC output capability makes it suitable for heavy-duty appliances, HVAC systems, pumps, and commercial equipment.
  • High surge handling capacity ensures reliable startup performance for motors, compressors, and other demanding loads.
  • Advanced transfer switching enables near-instant power switching between sources for uninterrupted operation.
  • Comprehensive protection suite safeguards against overload, short circuit, overheating, and battery irregularities.
  • Ideal for serious off-grid, backup, and hybrid solar systems requiring scalable, high-capacity, all-in-one power management.
                 
Q&A

Q: What is the AIMS Power PICOGLF10KW48V240VS3 used for?
A: Aims Power 10000 Watt Pure Sine Inverter Charger - PICOGLF10KW48V240VS3 is a high-capacity inverter/charger that converts 48V DC battery power into 120/240V AC split-phase electricity for whole-home backup, off-grid systems, and industrial power applications.

Q: What power output does it provide?
A: It delivers 10,000W continuous power with very high surge capacity (up to ~3× for short durations), making it suitable for starting large motors, pumps, and HVAC loads.

Q: What type of power does it produce?
A: It produces pure sine wave output, ensuring stable, utility-grade electricity safe for sensitive electronics and heavy-duty equipment.

Q: Is this an inverter charger system?
A: Yes. It includes a built-in multi-stage battery charger and automatic transfer switch, allowing seamless switching between grid/generator power and battery backup.

Q: What systems is it designed for?
A: It is designed for 48V battery banks in large off-grid homes, farms, workshops, and commercial or industrial backup power systems.

Q: What loads can it support?
A: It can run large household circuits, well pumps, air conditioners, refrigerators, power tools, and other high-demand 120/240V split-phase equipment.

Q: Does it include monitoring and protection features?
A: Yes. It includes LCD monitoring, programmable battery charging, multiple battery type settings, and full protection against overload, over/under-voltage, overheating, and short circuits.

Q: What makes this model industrial-grade?
A: Its 10kW continuous output, split-phase 120/240V capability, heavy surge handling, and integrated charger/transfer system make it suitable for continuous-duty, high-load environments.

                   
Maintenance Tips    
  • Install in a cool, dry, and well-ventilated electrical room to handle continuous high-load operation and heat from the charger section.
  • Keep forced-air cooling fans and internal vents clean and dust-free to prevent overheating and derating under heavy loads.
  • Regularly inspect 48V DC battery bank connections, busbars, and fuses; tighten and clean corrosion to reduce resistance and heat buildup.
  • Ensure correct battery configuration and settings (lead-acid, AGM, lithium profiles) for proper multi-stage charging performance.
  • Monitor system display for fault codes, temperature warnings, load percentage, and charging status to detect early issues.
  • Avoid exceeding 10,000W continuous / 30,000W surge (20 sec) capacity to protect inverter components.
  • Verify proper split-phase 120/240VAC balancing across loads to prevent inverter stress and uneven phase loading.
  • Check AC input (generator/grid) quality regularly—unstable waveform or poor regulation can affect charging performance.
  • Inspect and re-torque all high-current DC and AC terminals periodically due to thermal cycling in industrial use.
  • Keep installation away from moisture, vibration, and corrosive environments to extend lifespan of internal electronics.
  • Schedule preventive maintenance every 3–6 months: fan operation test, dust removal, and load/charge performance check.
  • Do not bypass protections (overload, over-temp, low/high voltage); these are critical for safe inverter operation.