{"product_id":"aims-power-30kw-pure-sine-power-inverter-charger-300vdc-208-vac-three-phase","title":"Aims Power 30KW 300VDC 208 VAC Pure Sine Three Phase Power Inverter Charger - PICOGLF30KW300V2083P","description":"\u003ch2\u003eAims Power 30KW 300VDC 208 VAC Pure Sine Three Phase Power Inverter Charger - PICOGLF30KW300V2083P\u003c\/h2\u003e\n\u003cdiv class=\"container\"\u003e\n\u003cdiv class=\"row main-content-wrap\"\u003e\n\u003cdiv class=\"main-content col-lg-12\"\u003e\n\u003cdiv class=\"content-area\" id=\"primary\"\u003e\u003cmain class=\"site-main\" id=\"content\"\u003e\n\u003cdiv class=\"product type-product post-4484 status-publish first instock product_cat-220-50 product_cat-230v product_cat-380-volt-pure-sine-inverter-chargers product_cat-ul-listed-power-inverters product_cat-european-inverters has-post-thumbnail purchasable product-type-simple product-layout-default\" id=\"product-4484\"\u003e\n\u003cdiv class=\"product-summary-wrap\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"summary entry-summary col-md-7\"\u003e\n\u003cdiv id=\"product-tab\" class=\"woocommerce-tabs woocommerce-tabs-anolzzmq resp-htabs\"\u003e\n\u003cdiv class=\"resp-tabs-container\"\u003e\n\u003cdiv aria-labelledby=\"tab_item-0\" id=\"tab-description\" class=\"tab-content resp-tab-content resp-tab-content-active\"\u003e\n\u003cp\u003e\u003cspan\u003eThat’s right! You read it correctly. We offer HUGE DC to AC pure sine inverter chargers 30KW up to 200KW.  Introducing the NEW AIMS extra large power inverter charger product line in 240 split phase or 208 three phase. This off-grid, back up power inverter is perfect for businesses, large homes, farms or other applications that require huge amounts of back-up power. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThese units have a large DC input range allowing you to create your own DC input source such as solar, wind, hydro and deep cycle batteries.  The higher DC input enables you to operate more efficiently when using this inverter. Its modular, simple and easy design allows for convenient access for maintenance and adjustments. The IPM provides high efficiency and stable performance prolonging the overall life of this inverter. The inverter also includes a power LCD display monitoring DC input, output frequency, phase voltage, phase current, AC bypass input voltage, output power kWH, time and date, temperature and fault codes. We also offer extended warranties. UL Listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/main\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDC INPUT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC input – 300 volt\u003c\/li\u003e\n\u003cli\u003eDC input range – 200-600 Vdc\u003c\/li\u003e\n\u003cli\u003eRated current amps – 100 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAC INPUT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e120 \/ 08 Vac\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAC OUTPUT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30,000 – 30kw\u003c\/li\u003e\n\u003cli\u003ePure sine wave\u003c\/li\u003e\n\u003cli\u003e480 VAC (+- 3%)\u003c\/li\u003e\n\u003cli\u003eThree phase L1 + L2 + L3 + N + Earth\u003c\/li\u003e\n\u003cli\u003eCurrent: 83.3 A phase current\u003c\/li\u003e\n\u003cli\u003eAdjustable 50\/60 hz\u003c\/li\u003e\n\u003cli\u003ePower Factor: \u0026gt;0.95\u003c\/li\u003e\n\u003cli\u003eInverter efficiency: \u0026gt;94%\u003c\/li\u003e\n\u003cli\u003eLCD Display\u003c\/li\u003e\n\u003cli\u003eVoltage accuracy – Load balancing\u0026lt;1%, Unbalance \u0026lt;5%\u003c\/li\u003e\n\u003cli\u003eTHD: linear load ,2%, nonlinear load \u0026gt;3%\u003c\/li\u003e\n\u003cli\u003eNo load amps: 2% of inverter size depending on DC voltage (1000 watts \/ DC input voltage = amps)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOverload 150% – 5 seconds, 120% for 35 seconds\u003c\/li\u003e\n\u003cli\u003eInput reverse polarity\u003c\/li\u003e\n\u003cli\u003eUnder voltage,\u003c\/li\u003e\n\u003cli\u003eOver voltage\u003c\/li\u003e\n\u003cli\u003eOutput over current\u003c\/li\u003e\n\u003cli\u003eShort circuit\u003c\/li\u003e\n\u003cli\u003eOver temperature\u003c\/li\u003e\n\u003cli\u003eFan cooled – Always on\u003c\/li\u003e\n\u003cli\u003eShort circuit: no automatic recovery. Restart required\u003c\/li\u003e\n\u003cli\u003e\u0026lt;50dB\u003c\/li\u003e\n\u003cli\u003eOperating temperature: -25 to 55 Celsius (-13 to 131 Fahrenheit)\u003c\/li\u003e\n\u003cli\u003eHumidity: 90% non-condensing\u003c\/li\u003e\n\u003cli\u003eDimensions: 33.5″D x 33.5″W x 51.2″H\u003c\/li\u003e\n\u003cli\u003eWeight: 926 lbs.\u003c\/li\u003e\n\u003cli\u003eCE, UL 1741 and CS22.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eWhat our Experts Think    \u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMassive 30kW three-phase output (208V AC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers industrial-level power for commercial, agricultural, and large off-grid installations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh-voltage 300V DC input system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e improves efficiency and reduces current losses across long cable runs in large battery banks.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePure sine wave output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ensures stable, utility-quality power suitable for sensitive industrial machinery, motors, and control systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInverter + charger functionality\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows seamless integration with generator or grid input for hybrid power system flexibility.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDesigned for heavy-duty continuous operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with industrial-grade components built for demanding environments and extended runtime.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIdeal for three-phase applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e including workshops, factories, farms, and large energy storage systems requiring balanced load distribution.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAdvanced system protections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e help safeguard against overload, short circuit, over-temperature, and DC input irregularities.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBest suited for large-scale professional installations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where reliability, scalability, and high power throughput are critical.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e               \u003cbr\u003eQ\u0026amp;A    \u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the AIMS Power PICOGLF30KW300V2083P used for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Aims Power 30KW 300VDC 208 VAC Pure Sine Three Phase Power Inverter Charger - PICOGLF30KW300V2083P is a high-capacity industrial inverter\/charger that converts high-voltage DC (typically solar, battery, wind, or hydro systems) into 208V three-phase AC power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What applications is this 30kW inverter designed for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is designed for commercial buildings, large off-grid homes, farms, factories, and heavy-duty backup power systems requiring stable three-phase electricity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the input and output specification?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It accepts around 300V DC input (wide operating range ~200–600V DC) and outputs 208V AC three-phase power with high efficiency for large electrical loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is this inverter suitable for solar systems?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. It works with solar arrays, battery banks, and hybrid renewable systems, especially where high-voltage DC input is used for efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What type of power output does it produce?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It delivers pure sine wave output, ensuring stable, utility-grade power suitable for sensitive industrial equipment and motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What loads can it support?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It can run heavy equipment such as industrial motors, HVAC systems, pumps, manufacturing machinery, and large-scale electrical distribution systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Does it include monitoring and control features?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. It includes an LCD control panel for monitoring voltage, frequency, load, power output, temperature, and fault codes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What protection features are included?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It includes overload, short-circuit, over\/under-voltage, over-temperature, and reverse polarity protection for system safety and reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: Why is this considered an industrial-grade inverter?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Its 30kW continuous output, three-phase architecture, high-voltage DC architecture, and \u0026gt;94% efficiency make it suitable for demanding continuous-duty industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e               \u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eInstall in a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etemperature-controlled, dust-free electrical room\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with strong ventilation to support continuous high-load operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eKeep all \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecooling fans, air intakes, and heat sinks clean\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; this 30kW unit uses forced-air cooling that must remain unobstructed.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRegularly inspect \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-voltage DC input (200–600V) and 208V three-phase AC terminals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for tightness, discoloration, or heat damage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eUse correctly rated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindustrial-grade cables, breakers, and busbars\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to handle ~100A DC input and ~83A per phase output safely.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMonitor the LCD panel for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efault codes, temperature, load %, and voltage imbalance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to detect issues early.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnsure \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eproper grounding and phase balancing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e across L1\/L2\/L3 to prevent overload or instability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eKeep operating temperature within \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-25°C to 55°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for optimal lifespan and efficiency.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAvoid sustained overloads above rated capacity; the unit allows short surge handling but not continuous overloading.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePerform periodic torque checks on all power connections due to vibration and thermal cycling in large installations.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSchedule preventive maintenance checks (fan operation, capacitor aging signs, dust buildup) every 3–6 months in heavy-use environments.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDo not bypass protections (over-current, reverse polarity, over-temp) as they are critical for IPM and inverter longevity.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOnly qualified technicians should service internal components due to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-voltage DC architecture and stored energy risks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e   \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"Aims Power","offers":[{"title":"Default Title","offer_id":45708620431551,"sku":"PICOGLF30KW300V2083P","price":7980.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/Aims_Power_30KW_300VDC_208_VAC_Pure_Sine_Three_Phase_Power_Inverter_Charger_Front.jpg?v=1780981327","url":"https:\/\/backyardprovider.com\/products\/aims-power-30kw-pure-sine-power-inverter-charger-300vdc-208-vac-three-phase","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}