Skip to product information
1 of 10

23ZERO

Aims Power 5000 Watt Pure Sine Power Inverter NEGATIVE 48 Volt Rack Mount Inverter To 120 Volt AC โ€“ 2U (-48V) - PRM5KWN48120S

Aims Power 5000 Watt Pure Sine Power Inverter NEGATIVE 48 Volt Rack Mount Inverter To 120 Volt AC โ€“ 2U (-48V) - PRM5KWN48120S

review stars 1 Review

5% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $1,443.00 Sale price $1,370.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$28.99

$70.00

$66.99

Add-Ons Bundle

$30.00

$28.99

$70.00

$66.99

Bundle Offer

$100.00

$95.98

Recently Viewed

Aims Power 5000 Watt Pure Sine Power Inverter NEGATIVE 48 Volt Rack Mount Inverter To 120 Volt AC โ€“ 2U (-48V) - PRM5KWN48120S

Ensure uninterrupted power with our advanced NEGATIVE 48V, 2U rackmount inverter, designed for telecom and data centers. Ideal for providing backup power to your essential equipment, this inverter generates 5000W of high-quality pure sine power at a stable 120Vac output. Thanks to the built-in 70 Amp transfer switch with a typical transfer time of less than 20ms, power is maintained seamlessly to your equipment. When city/utility power is available, it bypasses to provide consistent power. During outages, the inverter automatically switches to the backup DC power source, supplying power as long as the DC power supply provides enough voltage.

Monitoring is a breeze with the RS485 communication port, which offers real-time insights into DC input voltage, AC output voltage, frequency, and amps. Unmatched reliability, effortless integration, and consistent power supply ensure our rackmount inverter is the perfect solution for any setting where uninterrupted power is essential.

Features
  • 5000W continuous power, NEGATIVE 48 volt to 120 volt
  • Pure sine wave
  • 2U Rackmount
  • FCC Class B
  • RS485 Communication Port โ€“ Monitored from a PC
  • Input dc voltage
  • Output ac voltage
  • Frequency
  • AC Current
  • Digital status display โ€“ Toggle
  • Input dc voltage
  • Output ac voltage
  • Frequency
  • AC Current
  • Dual AC receptacle
  • On/off switch
  • Utility power bypass
  • Automatic transfer switch
  • Over temperature indicator
  • Overload protection
  • Low battery voltage warning/shutdown
  • High input voltage protection with automatic shutdown
  • Overload indicator
  • Short circuit protection
  • Thermal and load based fan
  • AC output short circuit protection
  • Instruction manual
  • Free lifetime tech support
Specifications
    • Continuous output power: 5000 Watts
    • Surge power capability (peak power): 10,000 Watts
    • DC input / operating voltage: Negative 41-60 Volts
    • Output voltage: 120 Volts ac
    • Output wave form: pure sine wave
    • Output frequency: 60 Hz
    • Low battery voltage shutdown: 40.6 Volts
    • Low battery voltage recovery: 42.7 Volts
    • Low battery voltage warning/shutdown
    • No load power consumption: Fan Off 0.7 A dc โ€“ Fan On 1.2 A dc
    • Frequency: 60/50Hz
    • Efficiency: 93%
    • Over temperature protection low: -4 F ยฑ 5ย  F
    • Over temperature protection high: 172 F ยฑ 5ย  F
    • Operating temperature recovery: 136ย  F (automatic shutdown) ยฑ 5ย  F
    • AC output socket type: dual Type 2 -3 prong
    • RS485 Communication Port
    • AC output and bypass protected: 50A Breaker
    • FCC Class B โ€“ F690501/RF-EMC000377(H)
    • Unit Weight: 31.5 lbs shipped 39 lbs
    • Unit Size W x D x H: 16.5 x 21 x 3.75 inches
    • Battery terminal size: Blade style .25โ€ณ diameter

    What our Experts Think
    • Telecom-Grade Rack Power: Purpose-built 2U rack-mount inverter designed for telecom, data centers, and critical backup systems where uptime is non-negotiable.
    • High-Capacity 5kW Output: Delivers 5000W continuous pure sine wave power with up to 10,000W surge, supporting heavy rack equipment, servers, networking gear, and sensitive electronics.
    • -48V DC System Compatibility: Optimized for negative 48V battery banks, a standard in telecom infrastructure, ensuring smooth integration into professional power architectures.
    • Seamless Automatic Transfer Switching: Built-in transfer switch (โ‰ˆ20ms) enables fast switching between grid and DC backup power to minimize downtime during outages.
    • High Efficiency & Monitoring: Up to ~93% efficiency with RS485 communication support for real-time system monitoring (voltage, load, frequency), ideal for managed installations.
    • Industrial Protection Features: Includes overload, short-circuit, thermal shutdown, and low/high voltage protection to ensure stable operation in demanding environments.
    Q&A

    Q: What is the AIMS Power PRM5KWN48120S inverter?
    A: The AIMS Power PRM5KWN48120S is a 5000W industrial-grade pure sine wave rack-mount inverter that converts -48V DC telecom or battery power into stable 120V AC output for critical systems like data centers and telecom equipment.

    Q: What is it used for?
    A: It is designed for telecom racks, server rooms, and backup power systems where uninterrupted, clean AC power is required for sensitive infrastructure.

    Q: How much power does it provide?
    A: It delivers 5000 watts continuous output with up to 10,000 watts surge capacity, supporting high-load equipment and startup surges.

    Q: What makes the -48V input special?
    A: The -48V DC input is a standard in telecom and networking systems, allowing direct integration with battery backup arrays commonly used in data centers.

    Q: Does it support automatic switching?
    A: Yes. It includes an automatic transfer/bypass function (typically under 20ms) to seamlessly switch between utility and DC backup power without interrupting connected loads.

    Q: Is it suitable for sensitive electronics?
    A: Yes. Its pure sine wave output ensures clean, stable power that is safe for servers, networking hardware, and mission-critical electronics.

    Q: Does it include monitoring features?
    A: Yes. It supports RS485 communication for real-time monitoring of input voltage, output load, frequency, and system status.

    Q: Who is this inverter best for?
    A: It is ideal for telecom operators, data centers, industrial backup systems, and professional installations requiring reliable rack-mounted power conversion.

    Maintenance Tips
    • Install in a cool, dry, rack-mounted, and well-ventilated telecom cabinet to prevent overheating and airflow restriction.
    • Regularly inspect -48V DC input terminals, bus bars, and grounding for tightness, corrosion, or heat discoloration.
    • Keep air filters, vents, and internal fans clean to maintain stable cooling under continuous load.
    • Monitor system via RS485 communication port to track input voltage, load, temperature, and fault conditions.
    • Ensure DC supply stays within -41V to -60V operating range to avoid low/high voltage shutdowns.
    • Periodically test automatic transfer/bypass function to confirm seamless switching during utility interruptions.
    • Check output breakers and AC distribution for overload signs or tripping events.
    • Schedule routine thermal inspections (especially under heavy load) to detect early signs of overheating.
    • Verify rack mounting stability and cable strain relief in vibration-prone telecom environments.