{"product_id":"aims-power-5000-watt-pure-sine-power-inverter-negative-48-volt-rack-mount-inverter-to-120-volt-ac-2u-48v","title":"Aims Power 5000 Watt Pure Sine Power Inverter NEGATIVE 48 Volt Rack Mount Inverter To 120 Volt AC – 2U (-48V) - PRM5KWN48120S","description":"\u003ch2\u003eAims Power 5000 Watt Pure Sine Power Inverter NEGATIVE 48 Volt Rack Mount Inverter To 120 Volt AC – 2U (-48V) - PRM5KWN48120S\u003c\/h2\u003e\n\u003cp\u003eEnsure uninterrupted power with our advanced NEGATIVE 48V, 2U rackmount inverter, designed for telecom and data centers. Ideal for providing backup power to your essential equipment, this inverter generates 5000W of high-quality pure sine power at a stable 120Vac output. Thanks to the built-in 70 Amp transfer switch with a typical transfer time of less than 20ms, power is maintained seamlessly to your equipment. When city\/utility power is available, it bypasses to provide consistent power. During outages, the inverter automatically switches to the backup DC power source, supplying power as long as the DC power supply provides enough voltage.\u003c\/p\u003e\n\u003cp\u003eMonitoring is a breeze with the RS485 communication port, which offers real-time insights into DC input voltage, AC output voltage, frequency, and amps. Unmatched reliability, effortless integration, and consistent power supply ensure our rackmount inverter is the perfect solution for any setting where uninterrupted power is essential.\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e5000W continuous power, NEGATIVE 48 volt to 120 volt\u003c\/li\u003e\n\u003cli\u003ePure sine wave\u003c\/li\u003e\n\u003cli\u003e2U Rackmount\u003c\/li\u003e\n\u003cli\u003eFCC Class B\u003c\/li\u003e\n\u003cli\u003eRS485 Communication Port – Monitored from a PC\u003c\/li\u003e\n\u003cli\u003eInput dc voltage\u003c\/li\u003e\n\u003cli\u003eOutput ac voltage\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eAC Current\u003c\/li\u003e\n\u003cli\u003eDigital status display – Toggle\u003c\/li\u003e\n\u003cli\u003eInput dc voltage\u003c\/li\u003e\n\u003cli\u003eOutput ac voltage\u003c\/li\u003e\n\u003cli\u003eFrequency\u003c\/li\u003e\n\u003cli\u003eAC Current\u003c\/li\u003e\n\u003cli\u003eDual AC receptacle\u003c\/li\u003e\n\u003cli\u003eOn\/off switch\u003c\/li\u003e\n\u003cli\u003eUtility power bypass\u003c\/li\u003e\n\u003cli\u003eAutomatic transfer switch\u003c\/li\u003e\n\u003cli\u003eOver temperature indicator\u003c\/li\u003e\n\u003cli\u003eOverload protection\u003c\/li\u003e\n\u003cli\u003eLow battery voltage warning\/shutdown\u003c\/li\u003e\n\u003cli\u003eHigh input voltage protection with automatic shutdown\u003c\/li\u003e\n\u003cli\u003eOverload indicator\u003c\/li\u003e\n\u003cli\u003eShort circuit protection\u003c\/li\u003e\n\u003cli\u003eThermal and load based fan\u003c\/li\u003e\n\u003cli\u003eAC output short circuit protection\u003c\/li\u003e\n\u003cli\u003eInstruction manual\u003c\/li\u003e\n\u003cli\u003eFree lifetime tech support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous output power: 5000 Watts\u003c\/li\u003e\n\u003cli\u003eSurge power capability (peak power): 10,000 Watts\u003c\/li\u003e\n\u003cli\u003eDC input \/ operating voltage: Negative 41-60 Volts\u003c\/li\u003e\n\u003cli\u003eOutput voltage: 120 Volts ac\u003c\/li\u003e\n\u003cli\u003eOutput wave form: pure sine wave\u003c\/li\u003e\n\u003cli\u003eOutput frequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eLow battery voltage shutdown: 40.6 Volts\u003c\/li\u003e\n\u003cli\u003eLow battery voltage recovery: 42.7 Volts\u003c\/li\u003e\n\u003cli\u003eLow battery voltage warning\/shutdown\u003c\/li\u003e\n\u003cli\u003eNo load power consumption: Fan Off 0.7 A dc – Fan On 1.2 A dc\u003c\/li\u003e\n\u003cli\u003eFrequency: 60\/50Hz\u003c\/li\u003e\n\u003cli\u003eEfficiency: 93%\u003c\/li\u003e\n\u003cli\u003eOver temperature protection low: -4 F ± 5  F\u003c\/li\u003e\n\u003cli\u003eOver temperature protection high: 172 F ± 5  F\u003c\/li\u003e\n\u003cli\u003eOperating temperature recovery: 136  F (automatic shutdown) ± 5  F\u003c\/li\u003e\n\u003cli\u003eAC output socket type: dual Type 2 -3 prong\u003c\/li\u003e\n\u003cli\u003eRS485 Communication Port\u003c\/li\u003e\n\u003cli\u003eAC output and bypass protected: 50A Breaker\u003c\/li\u003e\n\u003cli\u003eFCC Class B – F690501\/RF-EMC000377(H)\u003c\/li\u003e\n\u003cli\u003eUnit Weight: 31.5 lbs shipped 39 lbs\u003c\/li\u003e\n\u003cli\u003eUnit Size W x D x H: 16.5 x 21 x 3.75 inches\u003c\/li\u003e\n\u003cli\u003eBattery terminal size: Blade style .25″ diameter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\u003cbr\u003e\u003c\/h5\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTelecom-Grade Rack Power:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Purpose-built \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2U rack-mount inverter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for telecom, data centers, and critical backup systems where uptime is non-negotiable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh-Capacity 5kW Output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5000W continuous pure sine wave power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10,000W surge\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supporting heavy rack equipment, servers, networking gear, and sensitive electronics.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e-48V DC System Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Optimized for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enegative 48V battery banks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a standard in telecom infrastructure, ensuring smooth integration into professional power architectures.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSeamless Automatic Transfer Switching:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-in transfer switch (≈20ms) enables fast switching between grid and DC backup power to minimize downtime during outages.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh Efficiency \u0026amp; Monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to ~93% efficiency with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRS485 communication support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for real-time system monitoring (voltage, load, frequency), ideal for managed installations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIndustrial Protection Features:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes overload, short-circuit, thermal shutdown, and low\/high voltage protection to ensure stable operation in demanding environments.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the AIMS Power PRM5KWN48120S inverter?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The AIMS Power PRM5KWN48120S is a 5000W industrial-grade pure sine wave rack-mount inverter that converts -48V DC telecom or battery power into stable 120V AC output for critical systems like data centers and telecom equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is it used for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is designed for telecom racks, server rooms, and backup power systems where uninterrupted, clean AC power is required for sensitive infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: How much power does it provide?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It delivers 5000 watts continuous output with up to 10,000 watts surge capacity, supporting high-load equipment and startup surges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What makes the -48V input special?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The -48V DC input is a standard in telecom and networking systems, allowing direct integration with battery backup arrays commonly used in data centers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Does it support automatic switching?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. It includes an automatic transfer\/bypass function (typically under 20ms) to seamlessly switch between utility and DC backup power without interrupting connected loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is it suitable for sensitive electronics?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. Its pure sine wave output ensures clean, stable power that is safe for servers, networking hardware, and mission-critical electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Does it include monitoring features?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. It supports RS485 communication for real-time monitoring of input voltage, output load, frequency, and system status.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: Who is this inverter best for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is ideal for telecom operators, data centers, industrial backup systems, and professional installations requiring reliable rack-mounted power conversion.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eInstall in a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecool, dry, rack-mounted, and well-ventilated telecom cabinet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to prevent overheating and airflow restriction.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRegularly inspect \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-48V DC input terminals, bus bars, and grounding\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for tightness, corrosion, or heat discoloration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eKeep \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair filters, vents, and internal fans clean\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to maintain stable cooling under continuous load.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMonitor system via \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRS485 communication port\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to track input voltage, load, temperature, and fault conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnsure DC supply stays within \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-41V to -60V operating range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to avoid low\/high voltage shutdowns.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003ePeriodically test \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic transfer\/bypass function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to confirm seamless switching during utility interruptions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eCheck output breakers and AC distribution for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoverload signs or tripping events\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSchedule routine thermal inspections (especially under heavy load) to detect early signs of overheating.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVerify rack mounting stability and cable strain relief in vibration-prone telecom environments.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"23ZERO","offers":[{"title":"Default Title","offer_id":45708812714175,"sku":"PRM5KWN48120S","price":1370.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/PRM5KWN48V120S-Front-1000-x-1000-600x600_1.png?v=1780988587","url":"https:\/\/backyardprovider.com\/products\/aims-power-5000-watt-pure-sine-power-inverter-negative-48-volt-rack-mount-inverter-to-120-volt-ac-2u-48v","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}