{"product_id":"beckhoff-nema34-stepper-motor-n3-frame-5-0-nm-holding-torque-24-48-v-dc-as1060-0000","title":"Beckhoff NEMA34 Stepper Motor N3 Frame 5.0 Nm Holding Torque 24–48 V DC - AS1060-0000","description":"\u003ch2\u003e Beckhoff NEMA34 Stepper Motor N3 Frame 5.0 Nm Holding Torque 24–48 V DC - AS1060-0000\u003c\/h2\u003e\n\u003cp\u003eThe Beckhoff AS1060-0000 is a high-torque stepper motor designed for precise positioning and auxiliary axis control in industrial automation systems. With a 5.0 Nm holding torque and an N3 (NEMA34\/86 mm) flange size, it supports stable, repeatable motion in open-loop applications. It is intended for use with a motion terminal to provide the required power electronics.\u003c\/p\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed motion feedback interface:\u003c\/strong\u003e The Beckhoff EL5101 is a \u003cstrong\u003e1-channel EtherCAT incremental encoder terminal\u003c\/strong\u003e designed for precise position and speed measurement in industrial motion systems. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports multiple encoder types:\u003c\/strong\u003e Works with both \u003cstrong\u003edifferential RS422 encoders and TTL single-ended signals\u003c\/strong\u003e, making it highly versatile for automation retrofits and new builds. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVery high input frequency:\u003c\/strong\u003e Capable of processing signals up to \u003cstrong\u003e1 MHz (4 million increments\/s with quadrature decoding)\u003c\/strong\u003e for high-speed motion applications. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision measurement capability:\u003c\/strong\u003e Enables \u003cstrong\u003eperiod and frequency measurement with ~100 ns resolution\u003c\/strong\u003e, supporting accurate dynamic axis control. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced motion features:\u003c\/strong\u003e Includes microincrement interpolation, timestamping of edges, and distributed clock synchronization for deterministic EtherCAT systems. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in control functions:\u003c\/strong\u003e Supports latch, gate, and counter functions, allowing events like zero pulses and position capture. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial robustness:\u003c\/strong\u003e Designed for 24\/7 operation with electrical isolation and strong EMC resistance for harsh factory environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the Beckhoff C9900-U332-0010 battery pack used for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The C9900-U332-0010 is a 24 V DIN-rail mounted battery pack used as an energy storage unit for industrial PCs with integrated UPS functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is its main purpose in an automation system?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It provides backup power during mains failure, allowing the industrial PC to save data safely and shut down properly without corruption or data loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What type of systems is it designed for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is designed for Beckhoff Industrial PCs (especially Intel Atom–based systems) that include an integrated UPS power supply concept.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What are its key technical features?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It offers 24 V DC nominal voltage, 1.2 Ah capacity, maintenance-free VRLA AGM battery technology, and a compact DIN-rail metal housing for control cabinet installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: How is it installed?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The unit is mounted externally on a DIN rail (TS35), typically inside a control cabinet, and connected to the IPC’s UPS power system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What happens during a power failure?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The battery pack supplies short-term energy so the IPC can complete file writes, preserve system state, and perform a controlled shutdown.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Why is it important in industrial automation?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It protects PLC programs, machine data, and file systems from corruption, ensuring safe recovery and reducing downtime after unexpected power loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: What makes it different from a standard UPS?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is a dedicated industrial DC battery module designed specifically for seamless integration with Beckhoff IPC and UPS systems, rather than a standalone AC UPS device.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Check battery charge status regularly and replace when capacity drops below safe backup thresholds.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Ensure correct DIN-rail mounting and secure connection to the UPS system for reliable backup switching.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Keep operating environment within recommended temperature range to extend battery life and prevent degradation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Perform periodic discharge tests to verify actual backup time and UPS performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Inspect terminals and connectors for corrosion, looseness, or heat discoloration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Avoid deep discharge cycles to maximize lifespan of the 24 V 1.2 Ah battery pack.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Store spare batteries in a cool, dry environment and follow manufacturer storage guidelines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Keep ventilation clear around the UPS system to prevent overheating during charging cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Replace the battery pack only with approved models from Beckhoff Automation to ensure compatibility and safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Monitor UPS diagnostics for alarms, low-voltage warnings, or charging irregularities.\u003c\/span\u003e\u003c\/p\u003e","brand":"Beckhoff","offers":[{"title":"Default Title","offer_id":45746181079231,"sku":"AS1060-0000","price":229900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/s-l1600_20d2d3ad-ab64-4f9b-8c89-a8726fd852a0.jpg?v=1781778868","url":"https:\/\/backyardprovider.com\/products\/beckhoff-nema34-stepper-motor-n3-frame-5-0-nm-holding-torque-24-48-v-dc-as1060-0000","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}