{"product_id":"beckoff-analog-output-terminal-el4001","title":"Beckoff Analog Output Terminal - EL4001","description":"\u003ch2\u003eBeckoff Analog Output Terminal - EL4001 \u003c\/h2\u003e\n\u003cp\u003eThe Beckhoff EL4001 is a single-channel EtherCAT analog output terminal delivering 0 to 10 V signals with 12-bit resolutio\u003c\/p\u003e\n\u003cp\u003en and electrical isolation, ideal for precise industrial automation and process control.\u003c\/p\u003e\n\u003ch5\u003eSpecifications \u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-ekg0{background-color:#EFEFEF;font-weight:bold;text-align:left;vertical-align:top}\n.tg .tg-wjcf{background-color:#EFEFEF;text-align:left;vertical-align:middle}\n.tg .tg-txwv{background-color:#EFEFEF;text-align:left;vertical-align:top}\n\u003c\/style\u003e\n\u003ctable class=\"tg\" style=\"width: 99.915%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eCondition\u003c\/th\u003e\n\u003cth class=\"tg-wjcf\" style=\"width: 40.8866%;\"\u003eNew\/Never Used Surplus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\" style=\"width: 40.8866%;\"\u003eBeckoff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eCategory\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003ePLCs and Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd class=\"tg-wjcf\" style=\"width: 40.8866%;\"\u003eEL4001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eSubcategory\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003ePLC Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e0.06 kgs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e24 V DC via power contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eSignal Voltage\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e0…10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eLoad\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e\u0026gt; 5 kΩ (short-circuit proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e500 V (E-bus\/signal voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eConversion Time\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e~ 100 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eCurrent Consumption Power Contacts\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003etyp. 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eCurrent Consumption E-bus\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003etyp. 140 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e-25…+60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e-40…+85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003e95%, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-ekg0\" style=\"width: 59.0982%;\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd class=\"tg-txwv\" style=\"width: 40.8866%;\"\u003eIP20\/variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise analog signal output:\u003c\/strong\u003e The Beckhoff EL4001 is a \u003cstrong\u003esingle-channel EtherCAT analog output terminal\u003c\/strong\u003e designed to generate accurate \u003cstrong\u003e0–10 V control signals\u003c\/strong\u003e for industrial automation systems. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-resolution control:\u003c\/strong\u003e Provides \u003cstrong\u003e12-bit resolution\u003c\/strong\u003e, ensuring smooth and precise signal scaling for actuators, drives, and process control devices. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast, real-time response:\u003c\/strong\u003e Features a conversion time of approximately \u003cstrong\u003e100 µs\u003c\/strong\u003e, making it suitable for fast control loops in synchronized systems. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical isolation built-in:\u003c\/strong\u003e Includes \u003cstrong\u003e500 V isolation between E-bus and signal level\u003c\/strong\u003e, improving noise immunity in harsh industrial environments. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStable load handling:\u003c\/strong\u003e Designed for loads above \u003cstrong\u003e5 kΩ\u003c\/strong\u003e, ensuring reliable voltage output without signal distortion. \u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact DIN-rail design:\u003c\/strong\u003e Space-saving terminal housing enables high-density I\/O configuration inside control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal industrial applications:\u003c\/strong\u003e Commonly used for valve control, speed reference signals, analog setpoints, and PLC-to-drive communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the Beckhoff EL4001 Analog Output Terminal used for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The EL4001 is a single-channel EtherCAT analog output terminal used to generate precise voltage control signals (0–10 V) in industrial automation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What does the EL4001 do in a control system?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It converts digital process data from a PLC into a proportional analog voltage output, typically used to control drives, valves, actuators, and other analog devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What are its key technical features?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It provides 1 analog output channel, 0–10 V signal range, 12-bit resolution, electrical isolation, and fast conversion time (~100 µs) for precise control response.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Where is the EL4001 commonly used?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is used in machine automation, process control, HVAC systems, and motion control applications where variable analog voltage signals are required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: How does it integrate into a system?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It connects via EtherCAT and works with PLC systems from Beckhoff Automation using TwinCAT software for real-time control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What makes it suitable for industrial use?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It offers electrical isolation, DIN-rail mounting, rugged IP20 industrial design, and stable operation in harsh environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: Why choose the EL4001?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It provides a compact, cost-effective, and highly accurate way to generate analog control signals directly from a PLC system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Ensure correct 24V DC power supply and verify stable system voltage to maintain accurate analog output signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Check wiring polarity and terminal connections to avoid incorrect output levels or signal distortion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Keep the terminal and control cabinet clean, dry, and free from dust or conductive contaminants.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Regularly inspect output signal accuracy using calibrated measurement equipment to detect drift or faults early.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Maintain proper grounding and shielding of signal cables to reduce electrical noise and interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Ensure correct configuration in the Beckhoff Automation TwinCAT system for scaling and output range settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Periodically tighten field wiring and check for loose or corroded connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Avoid exceeding specified load limits on analog outputs to prevent damage to the terminal.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003e• Monitor for overheating or abnormal behavior during continuous operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Perform periodic system diagnostics to verify channel functionality and signal stability.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Beckoff","offers":[{"title":"Default Title","offer_id":45746000429247,"sku":"EL4001","price":84500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/b115070e84f8428f971cbfbcb2bb4bd0.jpg?v=1781775246","url":"https:\/\/backyardprovider.com\/products\/beckoff-analog-output-terminal-el4001","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}