{"product_id":"ge-q-line-thql-15-amp-1-pole-dual-function-afci-gfci-circuit-breaker","title":"GE Q-Line THQL 15-Amp 1-Pole Dual Function Afci\/Gfci Circuit Breaker - 71223234","description":"\u003ch2 class=\"romance\"\u003eGE Q-Line THQL 15-Amp 1-Pole Dual Function Afci\/Gfci Circuit Breaker - 71223234\u003c\/h2\u003e\n\u003cdiv class=\"romance\"\u003eThe 2014 National Electric Code has mandated Ground Fault and Arc Fault circuit protection on many 15 Amp and 20 Amp kitchen and laundry circuits. GE's dual function circuit interrupter offers both Ground Fault and combination Arc Fault (GFCI and AFCI) protection in a simple to apply and cost-effective solution. GFCI protection guards against Ground Fault and is an effective means of preventing electrical shocks. GFCI circuit breakers accomplish this by detecting when current is leaking somewhere outside its intended path. If your body provides the path to ground for this leakage you could be burned, shocked or even electrocuted. AFCI protection guards against damage or fires which can result from arcing and sparking that can arise from deteriorated wires, poor connections and breaches in wire insulation. With more than 67,000 home fires claiming more than 485 lives and injuring 2,300 victims annually, the added safety provided by AFCI protection is an important step forward in reducing this risk.\u003c\/div\u003e\n\u003cdiv class=\"romance\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"romance\"\u003e\n\u003ch5 class=\"romance\"\u003eFeatures\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cul class=\"bullets\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides Ground Fault and Arc Fault circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED blinks on trip to show the last know trip condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic and continuous self-testing feature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGE DFCI has important features for assisting you or your electrician in troubleshooting a trip, should the DFCI trip, the yellow LED will blink to indicate the last known trip condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnit's last known trip condition via LED indicators appear for 5 seconds each time the DFCI is turned on for up to 30 days\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnit’s last known trip condition can be cleared by performing a series of functions provided in the instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDFCI has a Self-Test feature that meets a June 2015 requirement from UL on all Ground Fault circuit breakers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe warranty is one (1) year from first use or eighteen (18) months from delivery, whichever occurs first\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"e8wv8h\" data-start=\"27\" data-end=\"203\"\u003e\n\u003cstrong data-start=\"29\" data-end=\"63\"\u003eDual Protection in One Breaker\u003c\/strong\u003e\u003cbr data-start=\"63\" data-end=\"66\"\u003eCombines \u003cstrong data-start=\"77\" data-end=\"130\"\u003eAFCI (arc-fault) + GFCI (ground-fault) protection\u003c\/strong\u003e, helping reduce risk of electrical fires and shock from a single device.\u003c\/li\u003e\n\u003cli data-section-id=\"5r2pcy\" data-start=\"205\" data-end=\"432\"\u003e\n\u003cstrong data-start=\"207\" data-end=\"246\"\u003eAdvanced Residential Safety Upgrade\u003c\/strong\u003e\u003cbr data-start=\"246\" data-end=\"249\"\u003eDesigned to meet modern code requirements for \u003cstrong data-start=\"297\" data-end=\"353\"\u003ekitchens, laundry areas, bedrooms, and living spaces\u003c\/strong\u003e where enhanced protection is required. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14euucz\" data-start=\"434\" data-end=\"632\"\u003e\n\u003cstrong data-start=\"436\" data-end=\"471\"\u003eFast Fault Detection Technology\u003c\/strong\u003e\u003cbr data-start=\"471\" data-end=\"474\"\u003eContinuously monitors circuit conditions and \u003cstrong data-start=\"521\" data-end=\"599\"\u003etrips instantly when dangerous arc faults or leakage currents are detected\u003c\/strong\u003e, improving safety response time.\u003c\/li\u003e\n\u003cli data-section-id=\"aq28d1\" data-start=\"634\" data-end=\"836\"\u003e\n\u003cstrong data-start=\"636\" data-end=\"668\"\u003eSelf-Test Reliability System\u003c\/strong\u003e\u003cbr data-start=\"668\" data-end=\"671\"\u003eBuilt-in \u003cstrong data-start=\"682\" data-end=\"745\"\u003eautomatic self-testing ensures ongoing protection integrity\u003c\/strong\u003e, reducing the risk of unnoticed failure over time. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bl7iha\" data-start=\"838\" data-end=\"1013\"\u003e\n\u003cstrong data-start=\"840\" data-end=\"868\"\u003eDiagnostic LED Indicator\u003c\/strong\u003e\u003cbr data-start=\"868\" data-end=\"871\"\u003eLED status light helps identify whether a trip was caused by \u003cstrong data-start=\"934\" data-end=\"963\"\u003earc fault or ground fault\u003c\/strong\u003e, simplifying troubleshooting and reset decisions.\u003c\/li\u003e\n\u003cli data-section-id=\"1au2mb6\" data-start=\"1015\" data-end=\"1182\"\u003e\n\u003cstrong data-start=\"1017\" data-end=\"1047\"\u003eSpace-Saving 1-Pole Design\u003c\/strong\u003e\u003cbr data-start=\"1047\" data-end=\"1050\"\u003eFits standard GE Q-Line load centers while providing \u003cstrong data-start=\"1105\" data-end=\"1151\"\u003etwo protection systems in one breaker slot\u003c\/strong\u003e, helping maximize panel space.\u003c\/li\u003e\n\u003cli data-section-id=\"ksriqm\" data-start=\"1184\" data-end=\"1357\"\u003e\n\u003cstrong data-start=\"1186\" data-end=\"1219\"\u003eProfessional Installation Use\u003c\/strong\u003e\u003cbr data-start=\"1219\" data-end=\"1222\"\u003eIntended for \u003cstrong data-start=\"1237\" data-end=\"1277\"\u003eGE\/ABB compatible residential panels\u003c\/strong\u003e, typically installed by licensed electricians for code-compliant wiring setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"97\" data-end=\"305\"\u003e\u003cstrong data-start=\"97\" data-end=\"138\"\u003eQ: What does this circuit breaker do?\u003c\/strong\u003e\u003cbr data-start=\"138\" data-end=\"141\"\u003eA: It provides \u003cstrong data-start=\"156\" data-end=\"175\"\u003edual protection\u003c\/strong\u003e by combining \u003cstrong data-start=\"189\" data-end=\"220\"\u003eAFCI (arc-fault protection)\u003c\/strong\u003e and \u003cstrong data-start=\"225\" data-end=\"259\"\u003eGFCI (ground-fault protection)\u003c\/strong\u003e in one device to reduce fire and shock risks.\u003c\/p\u003e\n\u003cp data-start=\"307\" data-end=\"466\"\u003e\u003cstrong data-start=\"307\" data-end=\"342\"\u003eQ: What is AFCI protection for?\u003c\/strong\u003e\u003cbr data-start=\"342\" data-end=\"345\"\u003eA: It detects dangerous electrical arcs caused by damaged wiring or loose connections and helps prevent electrical fires.\u003c\/p\u003e\n\u003cp data-start=\"468\" data-end=\"606\"\u003e\u003cstrong data-start=\"468\" data-end=\"503\"\u003eQ: What is GFCI protection for?\u003c\/strong\u003e\u003cbr data-start=\"503\" data-end=\"506\"\u003eA: It detects ground faults (current leakage) and quickly shuts off power to prevent electric shock.\u003c\/p\u003e\n\u003cp data-start=\"608\" data-end=\"788\"\u003e\u003cstrong data-start=\"608\" data-end=\"651\"\u003eQ: Where is this breaker commonly used?\u003c\/strong\u003e\u003cbr data-start=\"651\" data-end=\"654\"\u003eA: Typically required in residential circuits like bedrooms, kitchens, living areas, laundry rooms, and other code-required locations.\u003c\/p\u003e\n\u003cp data-start=\"790\" data-end=\"965\"\u003e\u003cstrong data-start=\"790\" data-end=\"829\"\u003eQ: Is it compatible with GE panels?\u003c\/strong\u003e\u003cbr data-start=\"829\" data-end=\"832\"\u003eA: Yes, it is designed for \u003cstrong data-start=\"859\" data-end=\"897\"\u003eGE Q-Line \/ PowerMark load centers\u003c\/strong\u003e and compatible ABB\/GE panels. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"967\" data-end=\"1182\"\u003e\u003cstrong data-start=\"967\" data-end=\"1014\"\u003eQ: Does it have safety or testing features?\u003c\/strong\u003e\u003cbr data-start=\"1014\" data-end=\"1017\"\u003eA: Yes, it includes a \u003cstrong data-start=\"1039\" data-end=\"1061\"\u003eself-test function\u003c\/strong\u003e and LED indicators that help identify trip conditions and improve troubleshooting. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1184\" data-end=\"1343\"\u003e\u003cstrong data-start=\"1184\" data-end=\"1223\"\u003eQ: What wire sizes does it support?\u003c\/strong\u003e\u003cbr data-start=\"1223\" data-end=\"1226\"\u003eA: It typically accepts \u003cstrong data-start=\"1250\" data-end=\"1304\"\u003e#14–8 AWG copper and #12–8 AWG aluminum conductors\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1345\" data-end=\"1531\"\u003e\u003cstrong data-start=\"1345\" data-end=\"1389\"\u003eQ: Is it certified for safety standards?\u003c\/strong\u003e\u003cbr data-start=\"1389\" data-end=\"1392\"\u003eA: Yes, it is \u003cstrong data-start=\"1406\" data-end=\"1454\"\u003eUL listed, NEMA approved, and ANSI certified\u003c\/strong\u003e for residential electrical safety use. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1533\" data-end=\"1756\"\u003e\u003cstrong data-start=\"1533\" data-end=\"1585\"\u003eQ: Why choose a dual-function AFCI\/GFCI breaker?\u003c\/strong\u003e\u003cbr data-start=\"1585\" data-end=\"1588\"\u003eA: It saves panel space and provides \u003cstrong data-start=\"1625\" data-end=\"1674\"\u003etwo critical safety protections in one device\u003c\/strong\u003e, meeting modern electrical code requirements while improving overall home safety.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1bi7h8f\" data-start=\"105\" data-end=\"241\"\u003e\n\u003cstrong data-start=\"107\" data-end=\"124\"\u003eTest monthly:\u003c\/strong\u003e Press the \u003cstrong data-start=\"135\" data-end=\"150\"\u003eTEST button\u003c\/strong\u003e to verify both AFCI (arc fault) and GFCI (ground fault) protection are working properly.\u003c\/li\u003e\n\u003cli data-section-id=\"1ma46ol\" data-start=\"242\" data-end=\"353\"\u003e\n\u003cstrong data-start=\"244\" data-end=\"273\"\u003eReset safely after trips:\u003c\/strong\u003e If it trips, fully switch it \u003cstrong data-start=\"303\" data-end=\"318\"\u003eOFF then ON\u003c\/strong\u003e to reset—don’t force it halfway.\u003c\/li\u003e\n\u003cli data-section-id=\"42xgpj\" data-start=\"354\" data-end=\"519\"\u003e\n\u003cstrong data-start=\"356\" data-end=\"385\"\u003eKeep panel dry and clean:\u003c\/strong\u003e Prevent moisture, dust, and insects inside the load center to avoid false trips or corrosion. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zrf5vt\" data-start=\"520\" data-end=\"645\"\u003e\n\u003cstrong data-start=\"522\" data-end=\"550\"\u003eInspect wiring annually:\u003c\/strong\u003e Have a licensed electrician check for loose neutrals, burnt terminals, or overheating signs.\u003c\/li\u003e\n\u003cli data-section-id=\"thpvog\" data-start=\"646\" data-end=\"759\"\u003e\n\u003cstrong data-start=\"648\" data-end=\"682\"\u003eAvoid overloading the circuit:\u003c\/strong\u003e Stay within \u003cstrong data-start=\"695\" data-end=\"711\"\u003e15-amp limit\u003c\/strong\u003e to prevent nuisance tripping and heat stress.\u003c\/li\u003e\n\u003cli data-section-id=\"k454vt\" data-start=\"760\" data-end=\"911\"\u003e\n\u003cstrong data-start=\"762\" data-end=\"787\"\u003eCheck LED indicators:\u003c\/strong\u003e Use trip lights to identify whether the issue is AFCI (arc) or GFCI (ground fault). \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10lx5mj\" data-start=\"912\" data-end=\"1085\"\u003e\n\u003cstrong data-start=\"914\" data-end=\"949\"\u003eDo not mix incompatible panels:\u003c\/strong\u003e Ensure it is installed only in compatible GE\/ABB load centers to maintain safety certification. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1r26hwj\" data-start=\"1086\" data-end=\"1220\"\u003e\n\u003cstrong data-start=\"1088\" data-end=\"1134\"\u003eSchedule periodic professional inspection:\u003c\/strong\u003e Dual-function breakers are safety-critical and benefit from yearly electrical review.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45604249305279,"sku":"Item # 71223234 | Model # THQL1115DFP","price":62.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/image_8e998616-c23f-444f-ae4a-79d93f4729d7.png?v=1777547034","url":"https:\/\/backyardprovider.com\/products\/ge-q-line-thql-15-amp-1-pole-dual-function-afci-gfci-circuit-breaker","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}