{"product_id":"greenlee-847-electric-pvc-heater-reconditioned-with-1-yr-warranty","title":"Greenlee 847 Electric PVC Heater - Reconditioned - 847","description":"\u003ch2\u003eGreenlee 847 Electric PVC Heater - Reconditioned - 847\u003c\/h2\u003e\n\u003cp\u003eThe PVC heater is a heavy-duty metal construction designed for bending PVC pipes ranging from 1\/2\" to 6\" in diameter, including all schedules. With a voltage rating of 230 VAC, a current rating of 30 AMP, and a wattage of 6600 to 7000 WATT, this tool is powered to efficiently heat up to 65\" long sections of pipe. The double wall metal construction with fiberglass insulation ensures fast and efficient heating, while the reflective interior further enhances the heating process. The heater features a heating chart, timer, and on\/off switch with an indicator light for added convenience. Double doors with piano hinges allow for heating shorter lengths of pipe with one door open, providing flexibility in use. The optional 31092 motorized PVC rotation kit for 847 and 857 PVC roller support can be added for enhanced functionality. Sturdy wheels make the heater easily mobile, allowing for convenient transportation to different job sites. To use, simply preheat for 10 minutes, open the lid, position the PVC pipe, close the lid, and rotate until the pipe becomes pliable. Then, open the lid, remove the PVC, and form the desired bend.\u003c\/p\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-WEB:9c9c8a5e-bd89-4e7a-bca9-60723b47a71b-16\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:9c9c8a5e-bd89-4e7a-bca9-60723b47a71b-16\" data-turn-id-container=\"request-WEB:9c9c8a5e-bd89-4e7a-bca9-60723b47a71b-16\" data-testid=\"conversation-turn-34\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"f19e424e-a66b-4669-b5d8-264158352a73\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cul data-start=\"28\" data-end=\"1229\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"81m0cl\" data-start=\"28\" data-end=\"226\"\u003e\n\u003cstrong data-start=\"30\" data-end=\"70\"\u003eProfessional PVC bending heat system\u003c\/strong\u003e – The Greenlee 847 Electric PVC Heater is designed to \u003cstrong data-start=\"125\" data-end=\"174\" data-is-only-node=\"\"\u003euniformly heat conduit for controlled bending\u003c\/strong\u003e, improving accuracy and reducing material stress.\u003c\/li\u003e\n\u003cli data-section-id=\"1bdlxoo\" data-start=\"227\" data-end=\"406\"\u003e\n\u003cstrong data-start=\"229\" data-end=\"267\"\u003eEven heat distribution performance\u003c\/strong\u003e – Provides consistent heating along PVC lengths, helping prevent \u003cstrong data-start=\"333\" data-end=\"388\" data-is-only-node=\"\"\u003eburning, weak spots, or deformation inconsistencies\u003c\/strong\u003e during forming.\u003c\/li\u003e\n\u003cli data-section-id=\"btln4z\" data-start=\"407\" data-end=\"568\"\u003e\n\u003cstrong data-start=\"409\" data-end=\"439\"\u003eJobsite efficiency booster\u003c\/strong\u003e – Speeds up conduit fabrication by eliminating uneven manual heating methods, supporting \u003cstrong data-start=\"529\" data-end=\"565\" data-is-only-node=\"\"\u003efaster and more repeatable bends\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"14zr4rl\" data-start=\"569\" data-end=\"714\"\u003e\n\u003cstrong data-start=\"571\" data-end=\"602\"\u003eLarge conduit compatibility\u003c\/strong\u003e – Suitable for a wide range of PVC conduit sizes used in \u003cstrong data-start=\"660\" data-end=\"711\" data-is-only-node=\"\"\u003ecommercial electrical and utility installations\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"1p7r60z\" data-start=\"715\" data-end=\"870\"\u003e\n\u003cstrong data-start=\"717\" data-end=\"747\"\u003eClean, flameless operation\u003c\/strong\u003e – Electric heating system offers a \u003cstrong data-start=\"783\" data-end=\"826\" data-is-only-node=\"\"\u003esafer alternative to open-flame methods\u003c\/strong\u003e, improving jobsite compliance and safety.\u003c\/li\u003e\n\u003cli data-section-id=\"gnzbvf\" data-start=\"871\" data-end=\"1043\"\u003e\n\u003cstrong data-start=\"873\" data-end=\"907\"\u003eDurable contractor-grade build\u003c\/strong\u003e – Engineered for repeated field use with rugged housing designed to withstand \u003cstrong data-start=\"986\" data-end=\"1040\" data-is-only-node=\"\"\u003econstruction environment wear and transport stress\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"ms6rxn\" data-start=\"1044\" data-end=\"1229\" data-is-last-node=\"\"\u003e\n\u003cstrong data-start=\"1046\" data-end=\"1079\"\u003eReconditioned value advantage\u003c\/strong\u003e – Factory-refurbished unit delivers \u003cstrong data-start=\"1116\" data-end=\"1160\" data-is-only-node=\"\"\u003eprofessional performance at reduced cost\u003c\/strong\u003e, ideal for contractors expanding PVC bending capability efficiently.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the Greenlee 847 Electric PVC Heater (Reconditioned)?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is an electric heating unit designed to soften PVC conduit so it can be bent cleanly for electrical installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is it used for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is used by electricians and contractors to heat PVC conduit evenly before bending it into precise shapes for conduit routing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What material does it work with?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is specifically designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePVC conduit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it flexible enough for bending without cracking or collapsing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: How does it work?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The heater warms the conduit evenly along its length until it becomes pliable, allowing controlled bending to the required angle.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What are the key benefits?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It helps create smooth, accurate bends, reduces conduit damage, and improves installation efficiency compared to manual heating methods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is it portable?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ejobsite-capable electric unit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but it is typically used in a fixed work area due to its size and power requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What power does it require?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It operates on standard \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectric jobsite power (typically 120V or 240V depending on configuration)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Who uses this equipment?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is used by professional electricians and construction crews working on commercial and industrial PVC conduit installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What does “reconditioned” mean?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It means the unit has been previously used and restored to working condition, though it may show cosmetic wear.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: Why use a PVC heater instead of manual bending?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Heating the conduit prevents cracking and ensures smoother, more precise bends, improving installation quality and durability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003cspan\u003e \u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-WEB:a54c8646-9a0f-4f08-b016-178b30554272-35\" data-is-intersecting=\"true\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:a54c8646-9a0f-4f08-b016-178b30554272-35\" data-turn-id-container=\"request-WEB:a54c8646-9a0f-4f08-b016-178b30554272-35\" data-testid=\"conversation-turn-72\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-3 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv data-conversation-screenshot-content=\"\" class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"908edf2e-53f4-4a42-aa82-1c6763a51fc3\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cul data-start=\"73\" data-end=\"808\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"6r8034\" data-start=\"73\" data-end=\"176\"\u003eInspect heating element and internal wiring before each use for damage, wear, or loose connections.\u003c\/li\u003e\n\u003cli data-section-id=\"1v0rb3x\" data-start=\"177\" data-end=\"262\"\u003eEnsure temperature controls and switches operate smoothly and respond accurately.\u003c\/li\u003e\n\u003cli data-section-id=\"far2rm\" data-start=\"263\" data-end=\"347\"\u003eClean heating chamber regularly to remove PVC residue, dust, and debris buildup.\u003c\/li\u003e\n\u003cli data-section-id=\"xt9abt\" data-start=\"348\" data-end=\"454\"\u003eDo not allow moisture to enter electrical components; keep unit completely dry during use and storage.\u003c\/li\u003e\n\u003cli data-section-id=\"19c79j6\" data-start=\"455\" data-end=\"540\"\u003eCheck power cord and plug for fraying, burns, or exposed wiring before operation.\u003c\/li\u003e\n\u003cli data-section-id=\"11fvwml\" data-start=\"541\" data-end=\"631\"\u003eAvoid overheating by following recommended temperature limits for PVC conduit bending.\u003c\/li\u003e\n\u003cli data-section-id=\"t51tlz\" data-start=\"632\" data-end=\"714\"\u003eKeep ventilation areas clear to prevent overheating and ensure safe operation.\u003c\/li\u003e\n\u003cli data-section-id=\"1lzrg33\" data-start=\"715\" data-end=\"808\" data-is-last-node=\"\"\u003eStore in a dry, protected environment to prevent corrosion and electrical component damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Greenlee","offers":[{"title":"Default Title","offer_id":45706345775295,"sku":"Greenlee 847","price":1410.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/847_845c44b3-3c8c-47a6-b21b-396e82616904.jpg?v=1780920929","url":"https:\/\/backyardprovider.com\/products\/greenlee-847-electric-pvc-heater-reconditioned-with-1-yr-warranty","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}