{"product_id":"pce-as1-particle-counter-air-sampler","title":"PCE  Particle Counter Air Sampler - AS1","description":"\u003ch2\u003ePCE  Particle Counter Air Sampler - AS1\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe PCE AS1 Particle Counter Air Sampler is designed to evaluate microbiological contamination and monitor hygiene. Ideal for use in hospitals, clean rooms, food and beverage facilities, as well as cosmetics and pharmaceutical production environments, the PCE-AS1 meets the latest standards for airborne microbial analysis devices. An optional ISO calibration lab certificate is also available\u003cbr\u003e\u003cbr\u003eThe PCE-AS1 air sampler uses the aerosol impaction principle or Andersen collision principle to assess air quality. The air taken in at the top of the instrument is pulled through 300 micropores and the resulting laminar air flow is directed onto the surface of an agar petri dish. When the sampling cycle is complete, the petri dish is removed and incubated. The bacterial and fungal counts can then be assessed in accordance with USP 797 and CAG-009 guidance.\u003cbr\u003e\u003cbr\u003eThe collecting head should be sterilized in an autoclave at 121° C for 30 minutes (sterilization with a cloth with 75% alcohol is also possible.) The petri dish should also be sterilized with 75% alcohol. \u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cli\u003eMemory for up to 99 parameters\u003c\/li\u003e\n\u003cli\u003eSterilizable collecting head\u003c\/li\u003e\n\u003cli\u003eAdjustable volumes of up to 6000 l\u003c\/li\u003e\n\u003cli\u003ePowerful battery\u003c\/li\u003e\n\u003cli\u003eUse of standard petri dishes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003e\n\u003cstrong\u003eHighlights\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePortable\u003c\/li\u003e\n\u003cli\u003e100 lpm aerosol hygiene monitoring device\u003c\/li\u003e\n\u003cli\u003eGreat for airborne microbial, microbiological, bacterial, mold, fungi and virus analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Air Quality \u0026amp; Particle Monitoring\u003c\/strong\u003e – The PCE-AS 1 provides reliable airborne particle sampling, helping users monitor cleanliness and environmental conditions with confidence.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for Controlled Environments\u003c\/strong\u003e – Well-suited for cleanrooms, laboratories, healthcare facilities, pharmaceutical production, and manufacturing environments where air quality is critical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast \u0026amp; Accurate Sampling\u003c\/strong\u003e – Delivers dependable particle collection and analysis support, enabling quick identification of contamination risks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable \u0026amp; Easy to Use\u003c\/strong\u003e – Compact design allows convenient on-site testing and routine environmental monitoring across multiple locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports Compliance \u0026amp; Quality Standards\u003c\/strong\u003e – Helps organizations maintain air quality requirements, improve contamination control, and support quality assurance programs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: What is the PCE-AS 1 Particle Counter Air Sampler used for?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: The PCE-AS 1 is designed to collect and analyze airborne particles for air quality monitoring, contamination control, and environmental testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Where is the PCE-AS 1 commonly used?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It is ideal for cleanrooms, laboratories, healthcare facilities, pharmaceutical environments, food production areas, and industrial workplaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Can the PCE-AS 1 help with air quality assessments?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. It assists in evaluating airborne contamination levels and maintaining compliance with air quality and cleanliness standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Is the PCE-AS 1 suitable for cleanroom monitoring?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. It is commonly used for cleanroom validation, environmental monitoring, and contamination control programs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eQ: Can sampling data be recorded and reviewed?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: Yes. The device supports data collection and documentation for reporting, analysis, and quality assurance purposes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQ: Why choose the PCE-AS 1 Particle Counter Air Sampler?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA: It provides reliable air sampling performance, easy operation, and dependable results for professional air quality and contamination monitoring applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep the sampling inlet clean\u003c\/strong\u003e and free from dust, debris, and obstructions to maintain accurate particle counts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerform regular calibration checks\u003c\/strong\u003e to ensure reliable and consistent measurement results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect and clean filters as recommended\u003c\/strong\u003e to maintain proper airflow and sampling efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStore the instrument in a clean, dry environment\u003c\/strong\u003e away from moisture, excessive heat, and direct sunlight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse the protective carrying case\u003c\/strong\u003e during transport and storage to prevent damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandle with care\u003c\/strong\u003e and avoid drops, impacts, or excessive vibration that may affect sensor accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep the battery properly charged\u003c\/strong\u003e for dependable field operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck airflow performance periodically\u003c\/strong\u003e to ensure the sampler is operating within specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBack up measurement data regularly\u003c\/strong\u003e and keep software updated when applicable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":45742830092479,"sku":"PCE-AS1","price":4200.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0683\/5703\/0079\/files\/pce-as1-particle-counter-air-sampler-770645.jpg?v=1781714982","url":"https:\/\/backyardprovider.com\/products\/pce-as1-particle-counter-air-sampler","provider":"Your Outdoor Setup Starts Here","version":"1.0","type":"link"}