Get In Touch
Get In Touch +1 (888) 575-2099
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4304GKA Air Conditioner Features:
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAXL304A Fan Coil Features:
Fan Coils
1.5-5 TON
600-2000 CFM
Model | WCA4304GKA,WAXL304A |
---|---|
AHRI Number | 9473254 |
Bundle Avg Coverage Area | 1,250 - 1,500 Sq Ft |
Bundle Cooling Capacity | 2.5 Ton |
Bundle Cooling Efficiency | 15 SEER |
EER | 13 |
WCA4304GKA Specifications | |
Model | WCA4304GKA |
Avg Coverage Area | 1,250 - 1,500 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 2.5 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 25 amps |
Product Height (in) | 31.4375 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 186.0000 |
WAXL304A Specifications | |
Model | WAXL304A |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 2.5 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 15 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 53.4375 |
Product Length (in) | 22.0625 |
Product Width (in) | 21.375 |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 146.0000 |
WCA4304GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAXL304A Fan Coil
1−1/2 Thru 5 Tons
Environmentally Sound R−410a Systems
Multiposition Installation − Upflow Or Horizontal Left Standard.
Horizontal Right With Minor Modification.
Field Convertible To Downflow With Available Accessory Kit.
Txv Metering Device Factory Installed
Sweat Connections
Primary And Secondary Drain Fittings With Brass Inserts
3 Amp Automotive Type Fuse In Wire Harness
Multiple Electrical Entry Locations
Time Delay Relay (TDR) Programmed In Motor
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch (25mm) Thick Insulation With R Value Of 4.2
Ecm Motor
No Heat (Plug) Kit Factory Installed
Filter (Washable) Factory Supplied
Q: What is the EcoTemp WCA4304GKA 2.5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4304GKA is a 2.5-ton, 15.5 SEER variable-speed central air conditioner split system, designed to efficiently cool medium to large residential or light commercial spaces with superior temperature control.
Q: What does SEER mean, and why is the 15.5 SEER rating important?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 15.5 SEER rating ensures the system provides high energy efficiency, which helps lower cooling costs while maintaining consistent comfort.
Q: How does the variable-speed feature enhance cooling performance?
A: The variable-speed blower motor adjusts the airflow based on cooling needs, resulting in quieter operation, better humidity control, and enhanced energy efficiency.
Q: Is the EcoTemp WCA4304GKA flexible in installation?
A: Yes, this is a multiposition system, offering flexibility for installation in horizontal, vertical, or upflow configurations to suit various home and business layouts.
Q: Why should I choose the EcoTemp WCA4304GKA air conditioner?
A: With its 15.5 SEER rating for energy efficiency, variable-speed technology for improved comfort, and versatile multiposition installation, the EcoTemp WCA4304GKA is an ideal choice for those seeking effective, quiet, and energy-efficient cooling.
Replace or Clean Air Filters: Inspect and clean or replace the air filters monthly. A clogged filter restricts airflow, reduces system efficiency, and may cause the system to overheat. Replace or clean every 1-3 months based on usage.
Clean the Coils: Clean both the evaporator and condenser coils annually to remove dirt and debris that can impair heat transfer. This maintenance will help your system run efficiently and prevent overheating.
Check Refrigerant Levels: Have a professional check refrigerant levels annually. Low refrigerant can lead to poor cooling and additional strain on the system. If levels are low, a licensed technician will need to top them up or check for leaks.
Clear Outdoor Unit of Debris: Ensure the outdoor condenser unit is clear of leaves, dirt, and vegetation. Maintain at least a 2-foot clearance around the unit to allow for proper airflow, which will prevent overheating and inefficiency.
Inspect and Clean the Condensate Drain: Periodically check the condensate drain for blockages. A clogged drain can cause water damage and contribute to mold growth. If necessary, clear the drain with a wet/dry vacuum or pipe cleaner.
Examine Ductwork for Leaks: Inspect the ductwork regularly for any signs of leaks, cracks, or disconnections. Leaky ducts can lead to inefficient cooling and higher energy costs. Seal any gaps to improve airflow.
Test the Thermostat: Ensure the thermostat is functioning correctly by checking its settings and verifying it’s maintaining the desired temperature. Consider upgrading to a smart thermostat for better control and energy savings.
Check Insulation: Ensure that the insulation around refrigerant lines and ducts is intact and free from damage. Proper insulation reduces energy loss and helps maintain cooling efficiency.
Ensure Unobstructed Airflow: Make sure all air vents and registers are open and unobstructed by furniture or other items. Blocked airflow can reduce the system's efficiency and cause it to work harder than necessary.
Schedule Annual Professional Maintenance: Have a professional technician perform an annual inspection and tune-up before the cooling season. This includes checking the refrigerant levels, cleaning coils, inspecting the blower motor, and ensuring the variable-speed system operates at optimal performance.
Thanks for subscribing!
This email has been registered!
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4304GKA Air Conditioner Features:
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAXL304A Fan Coil Features:
Fan Coils
1.5-5 TON
600-2000 CFM
Model | WCA4304GKA,WAXL304A |
---|---|
AHRI Number | 9473254 |
Bundle Avg Coverage Area | 1,250 - 1,500 Sq Ft |
Bundle Cooling Capacity | 2.5 Ton |
Bundle Cooling Efficiency | 15 SEER |
EER | 13 |
WCA4304GKA Specifications | |
Model | WCA4304GKA |
Avg Coverage Area | 1,250 - 1,500 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 2.5 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 25 amps |
Product Height (in) | 31.4375 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 186.0000 |
WAXL304A Specifications | |
Model | WAXL304A |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 2.5 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 15 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 53.4375 |
Product Length (in) | 22.0625 |
Product Width (in) | 21.375 |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 146.0000 |
WCA4304GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAXL304A Fan Coil
1−1/2 Thru 5 Tons
Environmentally Sound R−410a Systems
Multiposition Installation − Upflow Or Horizontal Left Standard.
Horizontal Right With Minor Modification.
Field Convertible To Downflow With Available Accessory Kit.
Txv Metering Device Factory Installed
Sweat Connections
Primary And Secondary Drain Fittings With Brass Inserts
3 Amp Automotive Type Fuse In Wire Harness
Multiple Electrical Entry Locations
Time Delay Relay (TDR) Programmed In Motor
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch (25mm) Thick Insulation With R Value Of 4.2
Ecm Motor
No Heat (Plug) Kit Factory Installed
Filter (Washable) Factory Supplied
Q: What is the EcoTemp WCA4304GKA 2.5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4304GKA is a 2.5-ton, 15.5 SEER variable-speed central air conditioner split system, designed to efficiently cool medium to large residential or light commercial spaces with superior temperature control.
Q: What does SEER mean, and why is the 15.5 SEER rating important?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 15.5 SEER rating ensures the system provides high energy efficiency, which helps lower cooling costs while maintaining consistent comfort.
Q: How does the variable-speed feature enhance cooling performance?
A: The variable-speed blower motor adjusts the airflow based on cooling needs, resulting in quieter operation, better humidity control, and enhanced energy efficiency.
Q: Is the EcoTemp WCA4304GKA flexible in installation?
A: Yes, this is a multiposition system, offering flexibility for installation in horizontal, vertical, or upflow configurations to suit various home and business layouts.
Q: Why should I choose the EcoTemp WCA4304GKA air conditioner?
A: With its 15.5 SEER rating for energy efficiency, variable-speed technology for improved comfort, and versatile multiposition installation, the EcoTemp WCA4304GKA is an ideal choice for those seeking effective, quiet, and energy-efficient cooling.
Replace or Clean Air Filters: Inspect and clean or replace the air filters monthly. A clogged filter restricts airflow, reduces system efficiency, and may cause the system to overheat. Replace or clean every 1-3 months based on usage.
Clean the Coils: Clean both the evaporator and condenser coils annually to remove dirt and debris that can impair heat transfer. This maintenance will help your system run efficiently and prevent overheating.
Check Refrigerant Levels: Have a professional check refrigerant levels annually. Low refrigerant can lead to poor cooling and additional strain on the system. If levels are low, a licensed technician will need to top them up or check for leaks.
Clear Outdoor Unit of Debris: Ensure the outdoor condenser unit is clear of leaves, dirt, and vegetation. Maintain at least a 2-foot clearance around the unit to allow for proper airflow, which will prevent overheating and inefficiency.
Inspect and Clean the Condensate Drain: Periodically check the condensate drain for blockages. A clogged drain can cause water damage and contribute to mold growth. If necessary, clear the drain with a wet/dry vacuum or pipe cleaner.
Examine Ductwork for Leaks: Inspect the ductwork regularly for any signs of leaks, cracks, or disconnections. Leaky ducts can lead to inefficient cooling and higher energy costs. Seal any gaps to improve airflow.
Test the Thermostat: Ensure the thermostat is functioning correctly by checking its settings and verifying it’s maintaining the desired temperature. Consider upgrading to a smart thermostat for better control and energy savings.
Check Insulation: Ensure that the insulation around refrigerant lines and ducts is intact and free from damage. Proper insulation reduces energy loss and helps maintain cooling efficiency.
Ensure Unobstructed Airflow: Make sure all air vents and registers are open and unobstructed by furniture or other items. Blocked airflow can reduce the system's efficiency and cause it to work harder than necessary.
Schedule Annual Professional Maintenance: Have a professional technician perform an annual inspection and tune-up before the cooling season. This includes checking the refrigerant levels, cleaning coils, inspecting the blower motor, and ensuring the variable-speed system operates at optimal performance.