The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4304GKA Air Conditioner Features
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAHL304B Fan Coil Features:
Fan Coils
1.5-5 TON
600-1750 CFM
Model | WCA4304GKA,WAHL304B |
---|---|
AHRI Number | 9473252 |
Bundle Avg Coverage Area | 1,250 - 1,500 Sq Ft |
Bundle Cooling Capacity | 2.5 Ton |
Bundle Cooling Efficiency | 15 SEER |
EER | 12.5 |
WCA4304GKA Specifications | |
Model | WCA4304GKA |
Avg Coverage Area | 1,250 - 1,500 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 2.5 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 20 amps |
Product Height (in) | 31.4375 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 186.0000 |
WAHL304B Specifications | |
Model | WAHL304B |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 2.5 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 15 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.06 |
Product Width (in) | 17.63 |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 122.0000 |
WCA4304GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAHL304B Fan Coil
1−1/2 Thru 5 Tons
Available For Environmentally Sound R−410a Systems
Factory Installed Txv Metering Device
Sweat Connections
Aluminum Tube, Aluminum Fin Evaporator
Primary And Secondary Drain Fittings
Multiple Electrical Entry Locations
Time Delay Relay (TDR)
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch Thick Insulation With R Value Of 4.2
Filter (Washable) Available As Accessory
Ecm 5−speed Motor
Multiposition Installation − Upflow Or Horizontal Left Standard, Horizontal Right With Minor Modification (Field
Convertible To Downflow With Available Accessory Kit)
Low Voltage Circuit Protective Fuse (3amp) Inline On Wire Harness
No Heat (Plug) Kit Factory Installed
Q: What is the EcoTemp WCA4304GKA 2.5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4304GKA is a 2.5-ton, 15 SEER multi-speed central air conditioner split system, designed to efficiently cool medium to large-sized residential or light commercial spaces.
Q: What does SEER mean, and how does it benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 15 SEER rating means this air conditioner provides energy-efficient cooling, reducing electricity costs while ensuring a consistent and comfortable indoor temperature.
Q: What is the benefit of a multi-speed air conditioner?
A: The multi-speed blower motor allows for adjustable airflow based on cooling demands, resulting in quieter operation and improved energy efficiency.
Q: Can the EcoTemp WCA4304GKA be installed in different configurations?
A: Yes, the system is a multiposition unit, allowing flexible installation in horizontal, vertical, or upflow positions to accommodate different home layouts.
Q: Why should I choose the EcoTemp WCA4304GKA air conditioner?
A: With its energy-efficient 15 SEER rating, flexible multiposition installation, and multi-speed functionality, the EcoTemp WCA4304GKA provides reliable and efficient cooling for a variety of applications.
Regularly Replace or Clean Air Filters: Inspect air filters every month, and replace or clean them every 1-3 months depending on usage. Dirty filters restrict airflow, reduce efficiency, and can lead to system overheating.
Clean Evaporator and Condenser Coils: Annual coil cleaning is essential to remove dirt and debris that can block heat transfer. Use a coil cleaner and soft brush to carefully clean both the evaporator and condenser coils to maintain peak efficiency.
Check Refrigerant Levels: Have a professional technician check the refrigerant levels annually. Low refrigerant levels can reduce cooling efficiency and cause unnecessary strain on the system.
Clear Debris from Outdoor Unit: Ensure that the outdoor condenser unit is free from debris like leaves, branches, or dirt. Maintain at least a 2-foot clearance around the unit to allow proper airflow and prevent overheating.
Inspect the Condensate Drain: Regularly check the condensate drain for clogs or blockages. A clogged drain can cause water damage and lead to mold growth. Use a wet/dry vacuum to clear any debris in the drain line.
Check and Seal Ductwork: Inspect ducts for leaks, holes, or disconnections. Leaky ducts reduce system efficiency and cause energy loss. Seal any gaps and have the ducts cleaned periodically to optimize airflow.
Test Thermostat Accuracy: Ensure the thermostat is properly calibrated and accurately maintaining the desired temperature. Consider upgrading to a programmable or smart thermostat to improve energy efficiency and cooling control.
Examine Insulation: Check the insulation around refrigerant lines and ducts for damage or wear. Insulation helps maintain system efficiency by reducing energy loss, so repair or replace damaged insulation as needed.
Ensure Proper Airflow: Make sure all vents and registers are unobstructed. Blocked vents can lead to poor airflow, causing the system to work harder and reducing overall efficiency. Ensure furniture or curtains do not block air passages.
Schedule Annual Professional Maintenance: Arrange for professional maintenance at least once a year, preferably before the cooling season begins. A technician will clean the coils, check refrigerant levels, inspect the blower, and ensure the overall system is functioning properly.
Thanks for subscribing!
This email has been registered!
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4304GKA Air Conditioner Features
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAHL304B Fan Coil Features:
Fan Coils
1.5-5 TON
600-1750 CFM
Model | WCA4304GKA,WAHL304B |
---|---|
AHRI Number | 9473252 |
Bundle Avg Coverage Area | 1,250 - 1,500 Sq Ft |
Bundle Cooling Capacity | 2.5 Ton |
Bundle Cooling Efficiency | 15 SEER |
EER | 12.5 |
WCA4304GKA Specifications | |
Model | WCA4304GKA |
Avg Coverage Area | 1,250 - 1,500 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 2.5 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 20 amps |
Product Height (in) | 31.4375 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 186.0000 |
WAHL304B Specifications | |
Model | WAHL304B |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 2.5 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 15 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.06 |
Product Width (in) | 17.63 |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 122.0000 |
WCA4304GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAHL304B Fan Coil
1−1/2 Thru 5 Tons
Available For Environmentally Sound R−410a Systems
Factory Installed Txv Metering Device
Sweat Connections
Aluminum Tube, Aluminum Fin Evaporator
Primary And Secondary Drain Fittings
Multiple Electrical Entry Locations
Time Delay Relay (TDR)
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch Thick Insulation With R Value Of 4.2
Filter (Washable) Available As Accessory
Ecm 5−speed Motor
Multiposition Installation − Upflow Or Horizontal Left Standard, Horizontal Right With Minor Modification (Field
Convertible To Downflow With Available Accessory Kit)
Low Voltage Circuit Protective Fuse (3amp) Inline On Wire Harness
No Heat (Plug) Kit Factory Installed
Q: What is the EcoTemp WCA4304GKA 2.5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4304GKA is a 2.5-ton, 15 SEER multi-speed central air conditioner split system, designed to efficiently cool medium to large-sized residential or light commercial spaces.
Q: What does SEER mean, and how does it benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 15 SEER rating means this air conditioner provides energy-efficient cooling, reducing electricity costs while ensuring a consistent and comfortable indoor temperature.
Q: What is the benefit of a multi-speed air conditioner?
A: The multi-speed blower motor allows for adjustable airflow based on cooling demands, resulting in quieter operation and improved energy efficiency.
Q: Can the EcoTemp WCA4304GKA be installed in different configurations?
A: Yes, the system is a multiposition unit, allowing flexible installation in horizontal, vertical, or upflow positions to accommodate different home layouts.
Q: Why should I choose the EcoTemp WCA4304GKA air conditioner?
A: With its energy-efficient 15 SEER rating, flexible multiposition installation, and multi-speed functionality, the EcoTemp WCA4304GKA provides reliable and efficient cooling for a variety of applications.
Regularly Replace or Clean Air Filters: Inspect air filters every month, and replace or clean them every 1-3 months depending on usage. Dirty filters restrict airflow, reduce efficiency, and can lead to system overheating.
Clean Evaporator and Condenser Coils: Annual coil cleaning is essential to remove dirt and debris that can block heat transfer. Use a coil cleaner and soft brush to carefully clean both the evaporator and condenser coils to maintain peak efficiency.
Check Refrigerant Levels: Have a professional technician check the refrigerant levels annually. Low refrigerant levels can reduce cooling efficiency and cause unnecessary strain on the system.
Clear Debris from Outdoor Unit: Ensure that the outdoor condenser unit is free from debris like leaves, branches, or dirt. Maintain at least a 2-foot clearance around the unit to allow proper airflow and prevent overheating.
Inspect the Condensate Drain: Regularly check the condensate drain for clogs or blockages. A clogged drain can cause water damage and lead to mold growth. Use a wet/dry vacuum to clear any debris in the drain line.
Check and Seal Ductwork: Inspect ducts for leaks, holes, or disconnections. Leaky ducts reduce system efficiency and cause energy loss. Seal any gaps and have the ducts cleaned periodically to optimize airflow.
Test Thermostat Accuracy: Ensure the thermostat is properly calibrated and accurately maintaining the desired temperature. Consider upgrading to a programmable or smart thermostat to improve energy efficiency and cooling control.
Examine Insulation: Check the insulation around refrigerant lines and ducts for damage or wear. Insulation helps maintain system efficiency by reducing energy loss, so repair or replace damaged insulation as needed.
Ensure Proper Airflow: Make sure all vents and registers are unobstructed. Blocked vents can lead to poor airflow, causing the system to work harder and reducing overall efficiency. Ensure furniture or curtains do not block air passages.
Schedule Annual Professional Maintenance: Arrange for professional maintenance at least once a year, preferably before the cooling season begins. A technician will clean the coils, check refrigerant levels, inspect the blower, and ensure the overall system is functioning properly.