The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4364GKA Air Conditioner Features:
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAHL364B Fan Coil Features
Fan Coils
1.5-5 TON
600-1750 CFM
Model | WCA4364GKA,WAHL364B |
---|---|
AHRI Number | 9529655 |
Bundle Avg Coverage Area | 1,500 - 1,800 Sq Ft |
Bundle Cooling Capacity | 3 Ton |
Bundle Cooling Efficiency | 14 SEER |
EER | 12 |
WCA4364GKA Specifications | |
Model | WCA4364GKA |
Avg Coverage Area | 1,500 - 1,800 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 3 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 30 amps |
Product Height (in) | 24.4375 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 151.0000 |
WAHL364BSpecifications | |
Model | WAHL364B |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 3 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 15 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.06 |
Product Width (in) | 17.63 |
Suction Line Size | 3/4 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 122.0000 |
WCA4364GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAHL364B Fan Coil
1−1/2 Thru 5 Tons
Available For Environmentally Sound R−410a Systems
Factory Installed Txv Metering Device
Sweat Connections
Aluminum Tube, Aluminum Fin Evaporator
Primary And Secondary Drain Fittings
Multiple Electrical Entry Locations
Time Delay Relay (TDR)
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch Thick Insulation With R Value Of 4.2
Filter (Washable) Available As Accessory
Ecm 5−speed Motor
Multiposition Installation − Upflow Or Horizontal Left Standard, Horizontal Right With Minor Modification (Field
Convertible To Downflow With Available Accessory Kit)
Low Voltage Circuit Protective Fuse (3amp) Inline On Wire Harness
No Heat (Plug) Kit Factory Installed
✓EcoTemp WCA4 Installation Manual
✓EcoTemp WCA4 Specification Manual
Q: What is the EcoTemp WCA4364GKA 3 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4364GKA is a 3-ton, 14 SEER multi-speed central air conditioner split system, designed to provide efficient cooling for larger residential or light commercial spaces.
Q: What is the meaning of SEER, and how does the 14 SEER rating benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 14 SEER rating ensures reliable cooling while helping to keep energy consumption and cooling costs lower compared to less efficient units.
Q: What does multi-speed functionality offer?
A: The multi-speed blower motor adjusts the airflow based on cooling demand, providing quieter operation, improved comfort, and better energy efficiency.
Q: Can the EcoTemp WCA4364GKA be installed in different positions?
A: Yes, this system is multiposition, offering flexibility for installation in horizontal, vertical, or upflow configurations to fit various space layouts.
Q: Why should I choose the EcoTemp WCA4364GKA air conditioner?
A: With its 14 SEER energy efficiency rating, multi-speed functionality, and versatile multiposition installation options, the EcoTemp WCA4364GKA offers reliable, flexible, and cost-effective cooling for larger spaces.
Clean or Replace Air Filters: Check air filters monthly and clean or replace them every 1-3 months. Clogged filters restrict airflow, reduce system efficiency, and can cause strain on the unit, leading to overheating or failure.
Clean Coils Annually: Clean both the evaporator and condenser coils at least once a year. Dust and debris buildup on the coils can reduce heat exchange and efficiency. Use a coil cleaner and a soft brush to remove dirt carefully.
Check Refrigerant Levels: Low refrigerant can affect cooling performance and put extra pressure on the system. Have a professional check refrigerant levels annually, and refill if necessary to ensure optimal performance.
Clear Outdoor Unit of Debris: Keep the outdoor condenser unit free from leaves, dirt, and vegetation. A clear, unobstructed space of at least 2 feet around the unit is essential for proper airflow and efficient cooling.
Inspect and Clean Condensate Drain: Check the condensate drain regularly for clogs, as a blocked drain can cause water damage and lead to mold growth. Use a wet/dry vacuum to clear debris from the line if needed.
Inspect Ductwork: Leaky or damaged ductwork can lead to energy loss and reduced cooling efficiency. Inspect ducts for visible signs of leaks or disconnections and seal any gaps. Clean ducts periodically to ensure proper airflow.
Check Thermostat Settings: Verify that your thermostat is functioning correctly and maintaining the desired temperature. If your system has a programmable or smart thermostat, adjust settings for optimal energy savings and performance.
Ensure Proper Insulation: Ensure that the insulation around refrigerant lines and ducts is intact. Damaged insulation can lead to energy loss and reduced efficiency. Replace any damaged insulation as needed.
Ensure Unobstructed Airflow: Keep all air vents and registers open and clear of obstructions, such as furniture or curtains. Blocked airflow can reduce cooling performance and increase the workload on the system.
Schedule Annual Professional Maintenance: Have a licensed HVAC technician perform an annual inspection and maintenance check-up. This includes cleaning coils, checking refrigerant levels, inspecting electrical components, and ensuring the multi-speed system operates properly.