EcoTemp WCA4424GKA 3.5 Ton 14 SEER Variable Speed Central Air Conditioner Split System - Multiposition - HA19773
EcoTemp WCA4424GKA 3.5 Ton 14 SEER Variable Speed Central Air Conditioner Split System - Multiposition - HA19773
EcoTemp WCA4424GKA 3.5 Ton 14 SEER Variable Speed Central Air Conditioner Split System - Multiposition - HA19773

EcoTemp WCA4424GKA 3.5 Ton 14 SEER Variable Speed Central Air Conditioner Split System - Multiposition - HA19773

FREE SHIPPING
CLEARANCE SALE
80 Peoples are also watching.
Brand: EcoTemp
SKU: HA19773
$3,186.99
$3,389.99
$3,186.99
Subtotal: $3,186.99
clearance sale ends in
00 Hours
00 Minutes
00 Seconds
authorized dealer, shop your favorite brand.
Expert Support,

Dial +1 (888) 575-2099

Limited Supply,

grab it before it's gone.

Lowest prices,

As low as possible.

All Items are brand New,

Never used.

EcoTemp WCA4424GKA 3.5 Ton 14 SEER Variable Speed Central Air Conditioner Split System - Multiposition - HA19773

EcoTemp WCA4424GKA 3.5 Ton 14 SEER Variable Speed Central Air Conditioner Split System - Multiposition - HA19773

$3,389.99 $3,186.99

EcoTemp WCA4424GKA 3.5 Ton 14 SEER Variable Speed Central Air Conditioner Split System - Multiposition - HA19773

$3,389.99 $3,186.99

Recently Viewed Products

Stay Cool Our Efficient And Durable Air Conditioning Units. Trust EcoTemp To Keep You Comfortable And Save You Money On Your Energy Bill.

The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.

Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.

The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.

WCA4424GKA Air Conditioner Features:

  • Air Conditioner

  • 14 Seer

  • R-410A Refrigerant

  • 1-5 Tons

  • Split System

  • 208/230 Volt

  • 1-Phase

  • 60 Hz

WAXL424A Fan Coil Features:

  • Fan Coils

  • 1.5-5 TON

  • 600-2000 CFM

Model WCA4424GKA,WAXL424A
AHRI Number 9507439
Bundle Avg Coverage Area 1,750 - 2,100 Sq Ft
Bundle Cooling Capacity 3.5 Ton
Bundle Cooling Efficiency 14 SEER
EER 11.5
WCA4424GKA Specifications
Model WCA4424GKA
Avg Coverage Area 1,750 - 2,100 Sq Ft
Compressor Single Stage
Cooling Capacity 3.5 Ton
Electrical Phase 1-Phase
Line Set Connection Type Sweat
Liquid Line Size 3/8 inch
Max Overcurrent Protection 35 amps
Product Height (in) 39.125
Product Length (in) 31.1875
Product Width (in) 31.1875
Refrigerant R-410a
Cooling Efficiency 14 SEER
Suction Line Size 7/8 inch
System Application Type Central Split Systems
Voltage 240
Warranty 10 Year Parts, 1 Year Unit Replacement
Weight (lbs) 232.0000
WAXL424A Specifications
Model WAXL424A
Air Flow Direction Downflow, Horizontal, Upflow
Configuration Floor Mounted
Blower Motor Variable Speed
Cooling Capacity 3.5 Ton
Electrical Phase 1-Phase
Heat Strip Compatibility Up to 20 kW
Line Set Connection Type Sweat
Liquid Line Size 3/8 inch
Max Overcurrent Protection 15 amps
Product Height (in) 49.625
Product Length (in) 22.0625
Product Width (in) 21.375
Suction Line Size 7/8 inch
System Application Type Central Split Systems
Voltage 240
Warranty 10 Year Parts
Weight (lbs) 157.0000


WCA4424GKA Air Conditioner

Refrigeration Circuit

  • Scroll compressors on all models

  • Copper tube / aluminum fin coil

Easy to Install and Service

  • Easy Access service valves on all models

  • External high and low refrigerant service ports

  • Only two screws to access control panel

  • Factory charged with R−410A refrigerant

Built to Last

  • Pre−painted cabinet finish over galvanized steel

  • Coated inlet grille with 3/8” (10mm) grille spacing for extra protection

WAXL424A Fan Coil

  • 1−1/2 Thru 5 Tons

  • Environmentally Sound R−410a Systems

  • Multiposition Installation − Upflow Or Horizontal Left Standard.

  • Horizontal Right With Minor Modification.

  • Field Convertible To Downflow With Available Accessory Kit.

  • Txv Metering Device Factory Installed

  • Sweat Connections

  • Primary And Secondary Drain Fittings With Brass Inserts

  • 3 Amp Automotive Type Fuse In Wire Harness

  • Multiple Electrical Entry Locations

  • Time Delay Relay (TDR) Programmed In Motor

  • Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately

  • Hud Approved For Manufactured Housing

  • 208/230−1−60 Supply Voltage

  • Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column

  • 1 Inch (25mm) Thick Insulation With R Value Of 4.2

  • Ecm Motor

  • No Heat (Plug) Kit Factory Installed

  • Filter (Washable) Factory Supplied

  • Energy-Efficient Cooling: With a 14 SEER rating, the EcoTemp WCA4424GKA ensures efficient energy use, reducing operating costs while delivering consistent, reliable cooling.
  • Variable Speed Technology: The variable speed motor adapts to cooling demands, providing smoother airflow and quieter operation for enhanced comfort.
  • 3.5-Ton Capacity: Ideal for larger homes, offering powerful cooling performance across multiple rooms, ensuring consistent comfort in all areas.
  • Multiposition Installation: Its flexible design allows for various installation options, ensuring compatibility with different home layouts and configurations.
  • Long-Lasting Durability: Crafted with durable, high-quality materials, ensuring this system delivers reliable performance for years to come.

Q: What is the EcoTemp WCA4424GKA 3.5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4424GKA is a 3.5-ton, 14 SEER variable-speed central air conditioner split system, designed to efficiently cool larger residential or light commercial spaces.

Q: What is SEER, and how does the 14 SEER rating benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 14 SEER rating means this system is designed to deliver efficient cooling while helping you save on energy costs compared to lower-rated units.

Q: How does the variable-speed feature improve performance?
A: The variable-speed blower motor adjusts airflow according to cooling needs, providing quieter operation, better humidity control, and increased overall energy efficiency.

Q: Is the EcoTemp WCA4424GKA flexible in installation?
A: Yes, this system is multiposition, offering flexible installation in horizontal, vertical, or upflow configurations to suit various space and layout requirements.

Q: Why should I choose the EcoTemp WCA4424GKA air conditioner?
A: With its 14 SEER energy efficiency, variable-speed technology for optimal comfort, and multiposition installation options, the EcoTemp WCA4424GKA is an ideal solution for reliable, cost-effective cooling in larger spaces.

  • Replace or Clean Air Filters: Inspect air filters monthly and clean or replace them every 1-3 months. Dirty filters can block airflow, reduce efficiency, and cause your system to overheat or work harder than necessary.

  • Clean Evaporator and Condenser Coils: Annual cleaning of the evaporator and condenser coils is essential. Dust and debris on the coils can impact heat exchange and reduce system efficiency. Use a soft brush and coil cleaner to remove dirt carefully.

  • Check Refrigerant Levels: Have a professional technician check the refrigerant levels at least once a year. Low refrigerant can cause reduced cooling efficiency and damage the compressor. If the levels are low, the technician will identify any leaks and top them off.

  • Clear Outdoor Unit of Debris: Ensure the outdoor condenser unit is free from leaves, dirt, and other debris. Keep at least a 2-foot clearance around the unit for proper airflow. Blocked airflow can cause overheating and decreased performance.

  • Inspect the Condensate Drain: Periodically inspect the condensate drain for clogs. A clogged drain can lead to water damage and the growth of mold. Use a wet/dry vacuum or a pipe cleaner to clear any blockages.

  • Inspect Ductwork for Leaks: Leaky or disconnected ducts can reduce airflow and system efficiency. Inspect your ducts regularly for leaks or damage and seal any gaps. Ensure ducts are clean to avoid airflow restrictions.

  • Check Thermostat Accuracy: Verify that your thermostat is correctly calibrated and accurately maintains the desired temperature. Consider upgrading to a smart or programmable thermostat to improve energy efficiency and better control your system.

  • Inspect Insulation: Ensure that the insulation around refrigerant lines and ducts is intact and in good condition. Damaged insulation can lead to energy loss, causing the system to work harder. Repair or replace any worn insulation as needed.

  • Ensure Proper Airflow: Make sure that all vents and registers are open and unobstructed by furniture or other items. Blocked airflow can reduce system efficiency, increase energy consumption, and strain the system.

  • Schedule Annual Professional Maintenance: Schedule a professional maintenance check annually to ensure that your system is operating at its best. A licensed technician will clean the coils, check refrigerant levels, inspect the variable-speed blower, and verify the overall performance of your system.

Related Products

Brand: Brand
Example product title
$3,186.99
$3,389.99
$3,186.99
Brand: Brand
Example product title
$3,186.99
$3,389.99
$3,186.99
Brand: Brand
Example product title
$3,186.99
$3,389.99
$3,186.99
Brand: Brand
Example product title
$3,186.99
$3,389.99
$3,186.99