The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4424GKA Air Conditioner Features:
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAXL424A Fan Coil Features:
Fan Coils
1.5-5 TON
600-2000 CFM
Model | WCA4424GKA,WAXL424A |
---|---|
AHRI Number | 9507439 |
Bundle Avg Coverage Area | 1,750 - 2,100 Sq Ft |
Bundle Cooling Capacity | 3.5 Ton |
Bundle Cooling Efficiency | 14 SEER |
EER | 11.5 |
WCA4424GKA Specifications | |
Model | WCA4424GKA |
Avg Coverage Area | 1,750 - 2,100 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 3.5 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 35 amps |
Product Height (in) | 39.125 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 232.0000 |
WAXL424A Specifications | |
Model | WAXL424A |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 3.5 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 20 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.0625 |
Product Width (in) | 21.375 |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 157.0000 |
WCA4424GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAXL424A Fan Coil
1−1/2 Thru 5 Tons
Environmentally Sound R−410a Systems
Multiposition Installation − Upflow Or Horizontal Left Standard.
Horizontal Right With Minor Modification.
Field Convertible To Downflow With Available Accessory Kit.
Txv Metering Device Factory Installed
Sweat Connections
Primary And Secondary Drain Fittings With Brass Inserts
3 Amp Automotive Type Fuse In Wire Harness
Multiple Electrical Entry Locations
Time Delay Relay (TDR) Programmed In Motor
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch (25mm) Thick Insulation With R Value Of 4.2
Ecm Motor
No Heat (Plug) Kit Factory Installed
Filter (Washable) Factory Supplied
Q: What is the EcoTemp WCA4424GKA 3.5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4424GKA is a 3.5-ton, 14 SEER variable-speed central air conditioner split system, designed to efficiently cool larger residential or light commercial spaces.
Q: What is SEER, and how does the 14 SEER rating benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 14 SEER rating means this system is designed to deliver efficient cooling while helping you save on energy costs compared to lower-rated units.
Q: How does the variable-speed feature improve performance?
A: The variable-speed blower motor adjusts airflow according to cooling needs, providing quieter operation, better humidity control, and increased overall energy efficiency.
Q: Is the EcoTemp WCA4424GKA flexible in installation?
A: Yes, this system is multiposition, offering flexible installation in horizontal, vertical, or upflow configurations to suit various space and layout requirements.
Q: Why should I choose the EcoTemp WCA4424GKA air conditioner?
A: With its 14 SEER energy efficiency, variable-speed technology for optimal comfort, and multiposition installation options, the EcoTemp WCA4424GKA is an ideal solution for reliable, cost-effective cooling in larger spaces.
Replace or Clean Air Filters: Inspect air filters monthly and clean or replace them every 1-3 months. Dirty filters can block airflow, reduce efficiency, and cause your system to overheat or work harder than necessary.
Clean Evaporator and Condenser Coils: Annual cleaning of the evaporator and condenser coils is essential. Dust and debris on the coils can impact heat exchange and reduce system efficiency. Use a soft brush and coil cleaner to remove dirt carefully.
Check Refrigerant Levels: Have a professional technician check the refrigerant levels at least once a year. Low refrigerant can cause reduced cooling efficiency and damage the compressor. If the levels are low, the technician will identify any leaks and top them off.
Clear Outdoor Unit of Debris: Ensure the outdoor condenser unit is free from leaves, dirt, and other debris. Keep at least a 2-foot clearance around the unit for proper airflow. Blocked airflow can cause overheating and decreased performance.
Inspect the Condensate Drain: Periodically inspect the condensate drain for clogs. A clogged drain can lead to water damage and the growth of mold. Use a wet/dry vacuum or a pipe cleaner to clear any blockages.
Inspect Ductwork for Leaks: Leaky or disconnected ducts can reduce airflow and system efficiency. Inspect your ducts regularly for leaks or damage and seal any gaps. Ensure ducts are clean to avoid airflow restrictions.
Check Thermostat Accuracy: Verify that your thermostat is correctly calibrated and accurately maintains the desired temperature. Consider upgrading to a smart or programmable thermostat to improve energy efficiency and better control your system.
Inspect Insulation: Ensure that the insulation around refrigerant lines and ducts is intact and in good condition. Damaged insulation can lead to energy loss, causing the system to work harder. Repair or replace any worn insulation as needed.
Ensure Proper Airflow: Make sure that all vents and registers are open and unobstructed by furniture or other items. Blocked airflow can reduce system efficiency, increase energy consumption, and strain the system.
Schedule Annual Professional Maintenance: Schedule a professional maintenance check annually to ensure that your system is operating at its best. A licensed technician will clean the coils, check refrigerant levels, inspect the variable-speed blower, and verify the overall performance of your system.
Thanks for subscribing!
This email has been registered!
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4424GKA Air Conditioner Features:
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAXL424A Fan Coil Features:
Fan Coils
1.5-5 TON
600-2000 CFM
Model | WCA4424GKA,WAXL424A |
---|---|
AHRI Number | 9507439 |
Bundle Avg Coverage Area | 1,750 - 2,100 Sq Ft |
Bundle Cooling Capacity | 3.5 Ton |
Bundle Cooling Efficiency | 14 SEER |
EER | 11.5 |
WCA4424GKA Specifications | |
Model | WCA4424GKA |
Avg Coverage Area | 1,750 - 2,100 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 3.5 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 35 amps |
Product Height (in) | 39.125 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 232.0000 |
WAXL424A Specifications | |
Model | WAXL424A |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 3.5 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 20 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.0625 |
Product Width (in) | 21.375 |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 157.0000 |
WCA4424GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAXL424A Fan Coil
1−1/2 Thru 5 Tons
Environmentally Sound R−410a Systems
Multiposition Installation − Upflow Or Horizontal Left Standard.
Horizontal Right With Minor Modification.
Field Convertible To Downflow With Available Accessory Kit.
Txv Metering Device Factory Installed
Sweat Connections
Primary And Secondary Drain Fittings With Brass Inserts
3 Amp Automotive Type Fuse In Wire Harness
Multiple Electrical Entry Locations
Time Delay Relay (TDR) Programmed In Motor
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch (25mm) Thick Insulation With R Value Of 4.2
Ecm Motor
No Heat (Plug) Kit Factory Installed
Filter (Washable) Factory Supplied
Q: What is the EcoTemp WCA4424GKA 3.5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4424GKA is a 3.5-ton, 14 SEER variable-speed central air conditioner split system, designed to efficiently cool larger residential or light commercial spaces.
Q: What is SEER, and how does the 14 SEER rating benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 14 SEER rating means this system is designed to deliver efficient cooling while helping you save on energy costs compared to lower-rated units.
Q: How does the variable-speed feature improve performance?
A: The variable-speed blower motor adjusts airflow according to cooling needs, providing quieter operation, better humidity control, and increased overall energy efficiency.
Q: Is the EcoTemp WCA4424GKA flexible in installation?
A: Yes, this system is multiposition, offering flexible installation in horizontal, vertical, or upflow configurations to suit various space and layout requirements.
Q: Why should I choose the EcoTemp WCA4424GKA air conditioner?
A: With its 14 SEER energy efficiency, variable-speed technology for optimal comfort, and multiposition installation options, the EcoTemp WCA4424GKA is an ideal solution for reliable, cost-effective cooling in larger spaces.
Replace or Clean Air Filters: Inspect air filters monthly and clean or replace them every 1-3 months. Dirty filters can block airflow, reduce efficiency, and cause your system to overheat or work harder than necessary.
Clean Evaporator and Condenser Coils: Annual cleaning of the evaporator and condenser coils is essential. Dust and debris on the coils can impact heat exchange and reduce system efficiency. Use a soft brush and coil cleaner to remove dirt carefully.
Check Refrigerant Levels: Have a professional technician check the refrigerant levels at least once a year. Low refrigerant can cause reduced cooling efficiency and damage the compressor. If the levels are low, the technician will identify any leaks and top them off.
Clear Outdoor Unit of Debris: Ensure the outdoor condenser unit is free from leaves, dirt, and other debris. Keep at least a 2-foot clearance around the unit for proper airflow. Blocked airflow can cause overheating and decreased performance.
Inspect the Condensate Drain: Periodically inspect the condensate drain for clogs. A clogged drain can lead to water damage and the growth of mold. Use a wet/dry vacuum or a pipe cleaner to clear any blockages.
Inspect Ductwork for Leaks: Leaky or disconnected ducts can reduce airflow and system efficiency. Inspect your ducts regularly for leaks or damage and seal any gaps. Ensure ducts are clean to avoid airflow restrictions.
Check Thermostat Accuracy: Verify that your thermostat is correctly calibrated and accurately maintains the desired temperature. Consider upgrading to a smart or programmable thermostat to improve energy efficiency and better control your system.
Inspect Insulation: Ensure that the insulation around refrigerant lines and ducts is intact and in good condition. Damaged insulation can lead to energy loss, causing the system to work harder. Repair or replace any worn insulation as needed.
Ensure Proper Airflow: Make sure that all vents and registers are open and unobstructed by furniture or other items. Blocked airflow can reduce system efficiency, increase energy consumption, and strain the system.
Schedule Annual Professional Maintenance: Schedule a professional maintenance check annually to ensure that your system is operating at its best. A licensed technician will clean the coils, check refrigerant levels, inspect the variable-speed blower, and verify the overall performance of your system.