Get In Touch
Get In Touch +1 (888) 575-2099
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4484GKA Air Conditioner Features:
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAHL484B Fan Coil Features:
Fan Coils
1.5-5 TON
600-1750 CFM
Model | WCA4484GKA,WAHL484B |
---|---|
AHRI Number | 9830427 |
Bundle Avg Coverage Area | 2,000 - 2,400 Sq Ft |
Bundle Cooling Capacity | 4 Ton |
Bundle Cooling Efficiency | 14 SEER |
EER | 12 |
WCA4484GKA Specifications | |
Model | WCA4484GKA |
Avg Coverage Area | 2,000 - 2,400 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 4 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 35 amps |
Product Height (in) | 28.4375 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 200.0000 |
WAHL484B Specifications | |
Model | WAHL484B |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 4 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 20 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.06 |
Product Width (in) | 21.63 |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 157.0000 |
WCA4484GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAHL484B Fan Coil
1−1/2 Thru 5 Tons
Available For Environmentally Sound R−410a Systems
Factory Installed Txv Metering Device
Sweat Connections
Aluminum Tube, Aluminum Fin Evaporator
Primary And Secondary Drain Fittings
Multiple Electrical Entry Locations
Time Delay Relay (TDR)
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch Thick Insulation With R Value Of 4.2
Filter (Washable) Available As Accessory
Ecm 5−speed Motor
Multiposition Installation − Upflow Or Horizontal Left Standard, Horizontal Right With Minor Modification (Field
Convertible To Downflow With Available Accessory Kit)
Low Voltage Circuit Protective Fuse (3amp) Inline On Wire Harness
No Heat (Plug) Kit Factory Installed
Q: What is the EcoTemp WCA4484GKA 4 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4484GKA is a 4-ton, 14.5 SEER multi-speed central air conditioner split system, designed to efficiently cool larger residential or light commercial spaces.
Q: What does SEER mean, and how does the 14.5 SEER rating benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 14.5 SEER rating ensures this air conditioner provides efficient cooling, helping you save on energy costs while maintaining a comfortable indoor environment.
Q: How does the multi-speed feature improve performance?
A: The multi-speed blower motor adjusts airflow according to cooling needs, offering quieter operation, enhanced comfort, and better energy efficiency.
Q: Can the EcoTemp WCA4484GKA be installed in different positions?
A: Yes, the system is multiposition, giving you flexibility to install it in horizontal, vertical, or upflow configurations depending on your space requirements.
Q: Why should I choose the EcoTemp WCA4484GKA air conditioner?
A: With its 14.5 SEER energy efficiency, multi-speed functionality for optimal comfort, and versatile multiposition installation options, the EcoTemp WCA4484GKA is perfect for larger spaces that require reliable and efficient cooling.
Replace or Clean Air Filters Regularly: Check air filters monthly and clean or replace them every 1-3 months, depending on usage. Dirty filters restrict airflow, reduce system efficiency, and can cause the unit to overheat or malfunction.
Clean the Coils: At least once a year, clean the evaporator and condenser coils to remove dirt, dust, and debris. Dirty coils reduce the system’s ability to transfer heat, which can cause poor cooling and energy inefficiency. Use a coil cleaner and a soft brush for gentle cleaning.
Check Refrigerant Levels: Have a licensed technician inspect the refrigerant levels annually. Low refrigerant levels can reduce cooling efficiency and cause long-term damage to the compressor. Ensure your refrigerant is at the proper level.
Clear Debris Around the Outdoor Unit: Keep the area around the outdoor condenser unit free from leaves, branches, and dirt. A clear space of at least 2 feet around the unit allows for proper airflow, preventing overheating and improving system efficiency.
Inspect and Clean the Condensate Drain: Check the condensate drain regularly for clogs, as a blockage can cause water damage, promote mold growth, and lead to system failure. Clear the drain using a wet/dry vacuum or pipe cleaner as necessary.
Inspect Ductwork for Leaks: Examine the ductwork for any visible leaks or gaps. Leaky ducts can reduce airflow and waste energy. Seal any gaps to ensure the system runs efficiently and delivers the intended amount of cool air to the living spaces.
Check and Calibrate the Thermostat: Ensure your thermostat is calibrated correctly and maintaining the desired temperature. If using a programmable or smart thermostat, set it to optimize energy savings by adjusting the temperature based on your schedule.
Inspect Insulation: Check the insulation around refrigerant lines and ducts. Damaged or deteriorated insulation can lead to energy loss. Replace any worn or damaged insulation to maintain efficiency and prevent the system from overworking.
Ensure Proper Airflow: Make sure all air vents are open and free from obstructions, such as furniture or drapes. Blocked vents can lead to reduced airflow, which affects cooling efficiency and causes the system to strain to maintain the temperature.
Schedule Annual Professional Maintenance: Arrange for an annual service visit from a professional technician. During the visit, the technician will clean the coils, check refrigerant levels, inspect electrical components, and ensure the multi-speed system is operating correctly and efficiently.
Thanks for subscribing!
This email has been registered!
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4484GKA Air Conditioner Features:
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAHL484B Fan Coil Features:
Fan Coils
1.5-5 TON
600-1750 CFM
Model | WCA4484GKA,WAHL484B |
---|---|
AHRI Number | 9830427 |
Bundle Avg Coverage Area | 2,000 - 2,400 Sq Ft |
Bundle Cooling Capacity | 4 Ton |
Bundle Cooling Efficiency | 14 SEER |
EER | 12 |
WCA4484GKA Specifications | |
Model | WCA4484GKA |
Avg Coverage Area | 2,000 - 2,400 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 4 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 35 amps |
Product Height (in) | 28.4375 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 200.0000 |
WAHL484B Specifications | |
Model | WAHL484B |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 4 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 20 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 49.625 |
Product Length (in) | 22.06 |
Product Width (in) | 21.63 |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 157.0000 |
WCA4484GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAHL484B Fan Coil
1−1/2 Thru 5 Tons
Available For Environmentally Sound R−410a Systems
Factory Installed Txv Metering Device
Sweat Connections
Aluminum Tube, Aluminum Fin Evaporator
Primary And Secondary Drain Fittings
Multiple Electrical Entry Locations
Time Delay Relay (TDR)
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch Thick Insulation With R Value Of 4.2
Filter (Washable) Available As Accessory
Ecm 5−speed Motor
Multiposition Installation − Upflow Or Horizontal Left Standard, Horizontal Right With Minor Modification (Field
Convertible To Downflow With Available Accessory Kit)
Low Voltage Circuit Protective Fuse (3amp) Inline On Wire Harness
No Heat (Plug) Kit Factory Installed
Q: What is the EcoTemp WCA4484GKA 4 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4484GKA is a 4-ton, 14.5 SEER multi-speed central air conditioner split system, designed to efficiently cool larger residential or light commercial spaces.
Q: What does SEER mean, and how does the 14.5 SEER rating benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 14.5 SEER rating ensures this air conditioner provides efficient cooling, helping you save on energy costs while maintaining a comfortable indoor environment.
Q: How does the multi-speed feature improve performance?
A: The multi-speed blower motor adjusts airflow according to cooling needs, offering quieter operation, enhanced comfort, and better energy efficiency.
Q: Can the EcoTemp WCA4484GKA be installed in different positions?
A: Yes, the system is multiposition, giving you flexibility to install it in horizontal, vertical, or upflow configurations depending on your space requirements.
Q: Why should I choose the EcoTemp WCA4484GKA air conditioner?
A: With its 14.5 SEER energy efficiency, multi-speed functionality for optimal comfort, and versatile multiposition installation options, the EcoTemp WCA4484GKA is perfect for larger spaces that require reliable and efficient cooling.
Replace or Clean Air Filters Regularly: Check air filters monthly and clean or replace them every 1-3 months, depending on usage. Dirty filters restrict airflow, reduce system efficiency, and can cause the unit to overheat or malfunction.
Clean the Coils: At least once a year, clean the evaporator and condenser coils to remove dirt, dust, and debris. Dirty coils reduce the system’s ability to transfer heat, which can cause poor cooling and energy inefficiency. Use a coil cleaner and a soft brush for gentle cleaning.
Check Refrigerant Levels: Have a licensed technician inspect the refrigerant levels annually. Low refrigerant levels can reduce cooling efficiency and cause long-term damage to the compressor. Ensure your refrigerant is at the proper level.
Clear Debris Around the Outdoor Unit: Keep the area around the outdoor condenser unit free from leaves, branches, and dirt. A clear space of at least 2 feet around the unit allows for proper airflow, preventing overheating and improving system efficiency.
Inspect and Clean the Condensate Drain: Check the condensate drain regularly for clogs, as a blockage can cause water damage, promote mold growth, and lead to system failure. Clear the drain using a wet/dry vacuum or pipe cleaner as necessary.
Inspect Ductwork for Leaks: Examine the ductwork for any visible leaks or gaps. Leaky ducts can reduce airflow and waste energy. Seal any gaps to ensure the system runs efficiently and delivers the intended amount of cool air to the living spaces.
Check and Calibrate the Thermostat: Ensure your thermostat is calibrated correctly and maintaining the desired temperature. If using a programmable or smart thermostat, set it to optimize energy savings by adjusting the temperature based on your schedule.
Inspect Insulation: Check the insulation around refrigerant lines and ducts. Damaged or deteriorated insulation can lead to energy loss. Replace any worn or damaged insulation to maintain efficiency and prevent the system from overworking.
Ensure Proper Airflow: Make sure all air vents are open and free from obstructions, such as furniture or drapes. Blocked vents can lead to reduced airflow, which affects cooling efficiency and causes the system to strain to maintain the temperature.
Schedule Annual Professional Maintenance: Arrange for an annual service visit from a professional technician. During the visit, the technician will clean the coils, check refrigerant levels, inspect electrical components, and ensure the multi-speed system is operating correctly and efficiently.