The Edan X8 Patient Monitor features a touch screen and includes a skin temperature probe, NIBP tubing, an adult cuff, a reusable SpO2 sensor, a battery, snap electrodes, a power cable, a 3-Lead ECG cable, and a grounding cable. The Edan Thermal Printer for X Series Monitors (#PM.PRINTER.X) is the appropriate printer for X Series Monitors. It MUST be purchased at the same time as the corresponding X Series Monitor. Please contact MFI Medical directly if you wish to add a printer to your order.
Data saved on the USB is encrypted. Users cannot simply see the vitals on a computer without the proper software. CMS/CMS-Lite software is required for viewing live to capture that data as a PDF. Alternatively an installed printer can be used to view results. Printers MUST be added to a monitor order at the time of purchase. Otherwise a $195 labor fee plus the cost of the printer will be added. Please select the with printer option at checkout or contact MFI directly before purchasing to make sure your order includes a printer.
Ideally suited for various environments such as general wards and in-hospital transfer units, the X8 Monitor fulfills primary clinical requirements and covers all patient types from neonate to adult.
Edan X8 Patient Monitor Features
Edan X8 Patient Monitor Configurations
Edan X8 Patient Monitor Literature
Edan X8/X10/X12 Patient Monitor Spec Sheet
Edan X8 Patient Monitor Brochure
Compact & Portable Design: Lightweight at just 5.0 lbs (2.3 kg), with a built-in handle for easy transport.
High-Resolution Thermal Printing: Produces clear, high-quality ECG strips at selectable speeds (25 or 50 mm/sec).
User-Friendly Interface: Features an intuitive touch panel and LCD display for waveform visualization.
Advanced Digital Filters: Equipped with filters to minimize baseline drift, AC, and EMG interference.
Flexible Operation Modes: Supports both auto and manual modes for versatile usage.
Lead-Off Detection: Alerts users to disconnected electrodes, ensuring accurate readings.
Long Battery Life: Built-in rechargeable lithium-ion battery provides over 3 hours of continuous operation.
Connectivity Options: Includes RS-232 port for data transfer and integration with other systems.
Durable Build: Designed to withstand the rigors of veterinary environments.
Q: What is the Edan VE-100 Veterinary EKG?
A: A portable, single-channel ECG designed for veterinary use, suitable for both small and large animals.
Q: What are its key features?
A: High-resolution thermal printer, adjustable print speeds (25/50 mm/sec), digital filters to reduce interference, auto/manual modes, lead-off detection, built-in rechargeable battery (3+ hours), RS-232 data output, LCD display, and compact design with a handle.
Q: Is it suitable for different animal sizes?
A: Yes, it works for both adult and neonatal animals, making it versatile for veterinary practices.
Q: Where can it be purchased?
A: Available through authorized veterinary equipment distributors.
Regular Inspection: Periodically check the device for any signs of wear, loose connections, or damage.
Proper Storage: Store the device in a clean, dry environment, free from dust and moisture.
Cleaning: Wipe the device with a soft, dry cloth. If necessary, use a mild detergent solution. Ensure the device is completely dry before storage or use.
Battery Care: Replace the battery when its useful life is over or if foul smell and leakage are detected. Only qualified service engineers authorized by EDAN can open the battery compartment and replace the battery.
Cable Management: Align the patient cable to avoid twisting, knotting, or bending at closed angles while using. Store the lead wires in a larger wheel. Replace the patient cable immediately if damage or aging is found.
Disinfection: Before disinfection, clean the equipment first. Then wipe the surface of the unit and patient cable with 70% isopropyl alcohol.
Lead-Off Detection: Ensure proper electrode placement and connection to avoid lead-off detection errors.