The HOTPOINT PTAC with Electric Heat (AH12E09D2B-KT, 230/208V, 15amp) is a reliable and energy-efficient packaged terminal air conditioner designed to deliver year-round comfort in residential and commercial spaces. Featuring built-in electric heat, this unit provides consistent warmth during colder months, while its high-efficiency cooling system ensures a comfortable indoor environment in the summer. Engineered for quiet operation, it minimizes noise while maintaining steady airflow, making it ideal for hotels, apartments, and office settings. The user-friendly controls and adjustable fan speeds allow for easy customization to meet individual comfort needs. With its durable construction and simple installation process, the Hotpoint PTAC is a practical and cost-effective climate control solution for any space.
Cooling BTUH (MAX) | 9200 |
---|---|
CFM Indoor Fan Low | 340 |
CFM Indoor Fan Medium | 391 |
CFM Indoor Fan High | 434 |
Cooling EER (BTUH / Watt) | 11.3 |
Cooling BTUH (MIN) | 9000 |
Installation | Through-the-Wall |
Color Appearance | White |
Warranty Notes | See written warranty for full details |
Labor Warranty | Limited 1-year entire appliance Limited 5-year sealed refrigerating system |
Parts Warranty | Limited 1-year entire appliance Limited 5-year sealed refrigerating system |
Cooling - Amperes | 3.5/3.8 |
Cooling - Watts | 810/795 |
Voltage (MIN) | 208 |
Heating - Electric - Heater Watts | 2535/2080 |
Voltage (MAX) | 230 |
Heating - Electric - Heater Amps | 10.8/9.8 |
Overall Width | 42.4 |
Approximate Shipping Weight | 108.7 |
Overall Height | 16 |
Overall Depth | 20.9 |
Net Weight | 98.1 |
Control Type | Electronic |
Fan Speed Selections | 3 Cooling 3 Fan Only 3 Heating |
Discharge Grille | 2-position |
Product Type | Packaged Terminal Air Conditioners (PTAC) |
Refrigerant Type | R32 |
Manual Vent Control | Hidden |
"SmartFan" Fan Cycle | Yes |
Chassis Type | Slide-In |
Fan Motor | 2 |
Unit Features | Auto Power Recovery Automatic Indoor Frost Control Central Desk Control Compatibility Freeze Sentinel Power Cord (LCDI) included Remote Thermostat Compatibility |
Temperature Range | 62 - 80 F |
Heat - Cool | Yes |
Auto Power Recovery | Yes |
Rotary Compressor | Yes |
Outdoor Vent / Exhaust | Yes |
Venting Features | Concealed Manual Vent Control Vent Air Filter |
Heating System | Electric Resistance |
Q: What are the key features of the HOTPOINT PTAC with Electric Heat - AH12E09D2B?
A: The HOTPOINT AH12E09D2B is a PTAC unit that offers both electric heating and cooling functions. It operates on 230/208V power with a 15-amp capacity, making it suitable for a variety of commercial and residential spaces like hotel rooms, apartments, and offices. It provides year-round comfort with efficient temperature control.
Q: What is the power requirement for this unit?
A: The HOTPOINT AH12E09D2B operates on 230/208V electrical power with a 15-amp capacity.
Q: Does this unit provide both heating and cooling?
A: Yes, the HOTPOINT AH12E09D2B provides electric heating for colder months and cooling for warmer months, making it a versatile solution for year-round comfort.
Q: What types of spaces is this unit ideal for?
A: The HOTPOINT AH12E09D2B is perfect for hotel rooms, apartments, offices, and other commercial or residential environments requiring reliable climate control.
Q: Is this PTAC unit energy-efficient?
A: Yes, the HOTPOINT AH12E09D2B is designed to be energy-efficient, helping to keep operating costs down while ensuring reliable heating and cooling performance.
Q: Does it come with a warranty?
A: Yes, the HOTPOINT AH12E09D2B comes with a manufacturer’s warranty. Be sure to check with the retailer for specific warranty details.
Q: Is professional installation required?
A: Yes, it is recommended to have the HOTPOINT AH12E09D2B installed by a professional technician to ensure proper setup and safe operation.
Clean the Air Filters Regularly – Check and clean the air filters every 1-3 months. Dirty filters can block airflow and decrease efficiency, leading to higher energy costs. Use a vacuum or wash them in warm water and allow them to dry thoroughly before reinserting.
Inspect the Coils Annually – Dust and dirt on the evaporator and condenser coils can cause the unit to overheat or perform inefficiently. Use a soft brush or vacuum cleaner to remove dust from the coils once a year.
Maintain the Condensate Drain – Ensure the condensate drain is free of debris to prevent water from backing up and potentially damaging the unit. Clear the drain line and check for blockages to avoid moisture buildup inside the unit.
Test the Thermostat – Ensure the thermostat is functioning properly. If the unit is not heating or cooling as expected, test the thermostat settings and verify that it maintains a consistent temperature. A malfunctioning thermostat may need recalibration or replacement.
Check the Heating Element – Inspect the electric heating element for any signs of damage or wear. A broken or worn-out element may cause heating issues. If you notice issues with the temperature or strange smells, have the element checked by a professional.
Examine the Fan and Motor – Regularly inspect the fan blades and motor. Look for dust accumulation or any blockages that may affect performance. Ensure the fan operates smoothly to prevent overheating and maintain airflow efficiency.
Look for Leaks – Inspect the unit for refrigerant or water leaks. Leaks can lead to reduced efficiency or cause damage to internal components. If you notice any leaks, contact a professional technician for repairs.
Check Electrical Connections – Inspect the power supply and electrical connections for any signs of wear, such as frayed wires or loose connections. Damaged electrical components should be replaced immediately to avoid safety hazards.
Exterior Cleaning – Clean the exterior of the unit regularly to maintain appearance and prevent dust from entering. Wipe down the surface with a damp cloth to keep the unit clean and operating smoothly.
Off-Season Care – When the unit is not in use for long periods, turn it off, clean it thoroughly, and store it in a dry, cool place to prevent dust buildup and damage.