Skip to product information
1 of 11

HOTPOINT

HOTPOINT PTAC with Electric Heat 230/208V, 30amp - AH12E12D5B-KT

HOTPOINT PTAC with Electric Heat 230/208V, 30amp - AH12E12D5B-KT

1 Review

5% Sale

Only left!

image

Free Delivary

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $866.00 Sale price $822.99
Shipping calculated at checkout.

Quintity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

HOTPOINT PTAC with Electric Heat 230/208V, 30amp - AH12E12D5B-KT

The HOTPOINT PTAC with Electric Heat (AH12E12D5B-KT, 230/208V, 30amp) is a powerful and efficient packaged terminal air conditioner designed for year-round comfort in residential and commercial settings. With integrated electric heating and high-efficiency cooling, this unit ensures consistent temperature control in any season. Its quiet operation makes it ideal for hotels, apartments, and office spaces, providing a comfortable environment without excessive noise. Featuring user-friendly controls and adjustable fan speeds, it allows for easy customization to meet specific comfort needs. Built for durability and long-lasting performance, the Hotpoint PTAC is designed for easy installation and maintenance, making it a practical and cost-effective climate control solution.

Specifications
Cooling BTUH (MAX) 12000
CFM Indoor Fan Low 310
CFM Indoor Fan Medium 348
CFM Indoor Fan High 383
Cooling EER (BTUH / Watt) 10.7
Cooling BTUH (MIN) 11800
Installation Through-the-Wall
Color Appearance White
Warranty Notes See written warranty for full details
Labor Warranty Limited 1-year entire appliance
Limited 5-year sealed refrigerating system
Parts Warranty Limited 1-year entire appliance
Limited 5-year sealed refrigerating system
Cooling - Amperes 4.9/5.3
Cooling - Watts 1120/1100
Voltage (MIN) 208
Heating - Electric - Heater Watts 5035/4124
Voltage (MAX) 230
Heating - Electric - Heater Amps 22.0/19.7
Overall Width 42.4
Approximate Shipping Weight 119.5
Overall Height 16
Overall Depth 20.9
Net Weight 108.7
Control Type Electronic
Fan Speed Selections 3 Cooling
3 Fan Only
3 Heating
Discharge Grille 2-position
Product Type Packaged Terminal Air Conditioners (PTAC)
Refrigerant Type R32
Manual Vent Control Hidden
"SmartFan" Fan Cycle Yes
Chassis Type Slide-In
Fan Motor 2
Unit Features Auto Power Recovery
Automatic Indoor Frost Control
Central Desk Control Compatibility
Freeze Sentinel
Power Cord (LCDI) included
Remote Thermostat Compatibility
Temperature Range 62 - 80 F
Heat - Cool Yes
Auto Power Recovery Yes
Rotary Compressor Yes
Outdoor Vent / Exhaust Yes
Venting Features Concealed Manual Vent Control
Vent Air Filter
Heating System Electric Resistance
What Our Experts Think
  • Electric Heat Technology: Provides both reliable cooling and heating, offering all-season comfort.
  • 230/208V Compatibility: Suitable for a wide range of electrical systems, ensuring flexibility during installation.
  • 30amp Power: Designed to handle larger spaces, delivering powerful performance while maintaining energy efficiency.
  • Compact and Efficient: Space-saving design, ideal for commercial or residential environments where space is at a premium.
  • Quiet Operation: Operates quietly, ensuring a comfortable and peaceful environment.
Q&A

Q: What are the key features of the HOTPOINT PTAC with Electric Heat - AH12E12D5B?
A: The HOTPOINT AH12E12D5B is a PTAC unit that combines electric heating and cooling functions, designed for year-round climate control. It operates on 230/208V electrical power and requires a 30-amp electrical connection, making it suitable for larger commercial or residential spaces like hotel rooms, apartments, and offices.

Q: What is the power requirement for this unit?
A: The HOTPOINT AH12E12D5B requires 230/208V power with a 30-amp electrical connection.

Q: Does this unit provide both heating and cooling?
A: Yes, the HOTPOINT AH12E12D5B offers electric heating for cold weather and cooling for warmer temperatures, providing effective temperature control throughout the year.

Q: What types of spaces is this unit ideal for?
A: The HOTPOINT AH12E12D5B is perfect for larger commercial spaces, such as hotel rooms, apartments, offices, and other buildings that require a reliable climate control solution.

Q: Is this PTAC unit energy-efficient?
A: Yes, the HOTPOINT AH12E12D5B is designed to be energy-efficient, helping to minimize electricity usage while providing optimal performance for both heating and cooling.

Q: Does it come with a warranty?
A: Yes, the HOTPOINT AH12E12D5B includes a manufacturer’s warranty. You should verify specific warranty terms with the retailer.

Q: Is professional installation required?
A: Yes, it is highly recommended to have the HOTPOINT AH12E12D5B installed by a professional technician to ensure proper installation and safety.

Maintenance Tips
  • Regularly Clean Air Filters – Clean the air filters every 1-3 months to prevent dust buildup and maintain airflow efficiency. You can vacuum the filters or wash them in warm water, ensuring they dry completely before reinstalling.

  • Inspect the Coils Annually – Dust and dirt can accumulate on both the evaporator and condenser coils, reducing the unit's efficiency. Use a soft brush or a vacuum to clean the coils once a year to prevent them from overheating or becoming clogged.

  • Check the Condensate Drain – Clear any debris from the condensate drain to avoid water backup. A blocked drain can cause moisture buildup inside the unit, leading to potential mold and damage.

  • Test the Thermostat Regularly – Verify that the thermostat is set to the desired temperature and operating correctly. If the unit is not heating or cooling as it should, it might need recalibration or replacement.

  • Examine the Heating Element – Inspect the electric heating element for visible signs of wear, cracks, or damage. If the heating performance is weak or inconsistent, the element may need to be repaired or replaced.

  • Check the Fan and Motor – Inspect the fan blades and motor for any obstructions, damage, or excessive dust buildup. Ensure that the fan operates smoothly and efficiently to maintain proper air circulation.

  • Monitor for Leaks – Check for any refrigerant or water leaks around the unit. Leaks can cause the system to operate inefficiently or lead to internal damage. If leaks are detected, consult a technician for repairs.

  • Inspect Electrical Connections – Ensure the unit's electrical connections are secure and free of wear. Loose or damaged wiring could lead to performance issues or potential safety hazards. Contact a professional if you observe any problems.

  • Regular Exterior Cleaning – Wipe down the exterior of the unit regularly to remove dust and debris, which can affect its performance and appearance.

  • Off-Season Care – When the unit is not in use, switch it off, clean the filters and coils, and store it in a dry location. This will help prevent dust accumulation and ensure it remains in good working condition when needed.