Skip to product information
1 of 10

True Mfg

True Mfg. - General Foodservice Reach-In & Freezers - T-43F-HC

True Mfg. - General Foodservice Reach-In & Freezers - T-43F-HC

review stars 1 Review

5% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $7,202.94 Sale price $6,842.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$28.99

$70.00

$66.99

Add-Ons Bundle

$30.00

$28.99

$70.00

$66.99

Bundle Offer

$100.00

$95.98

Recently Viewed

True Mfg. - General Foodservice  Reach-In & Freezers - T-43F-HC

47″ wide | -10 °F holding temperature | Hydrocarbon refrigerant

Engineered and built in the USA, the True T-43F-HC delivers dependable -10 °F performance, energy-saving refrigeration technology, and the rock-solid construction chefs have trusted for decades.

Features                    
  • High-capacity R290 refrigeration system with electronically commutated (ECM) fan motors slashes energy consumption.
  • Factory-balanced design maintains a steady -10 °F (-23.3 °C) – perfect for ice cream and long-term frozen storage.
  • Stainless steel doors & front resist dents and scratches; lifetime-guaranteed hinges and torsion closures.
  • Six heavy-duty, PVC-coated wire shelves adjust on ½″ increments to accommodate every product mix.
  • Bright, safety-shielded LED lighting and an exterior digital temperature display keep monitoring effortless.
  • Bottom-mounted 1 HP compressor is easy to service and creates a convenient, “no-stoop” lower shelf.
  • 4″ diameter castors (locking front set) provide instant mobility for cleaning or kitchen re-layout.

Built to last

  • Foamed-in-place, high-density polyurethane insulation—zero ODP & zero GWP.
  • Anodized aluminum sides and interior walls with a seamless stainless steel floor and hygienic coved corners.
  • Lockable, self-closing doors with 12″ recessed handles; magnetic gaskets pop out without tools for quick cleaning.

Simple, reliable operation

  • Time-initiated, temperature-terminated automatic defrost shortens cycles and saves energy.
  • Ships completely pre-wired with a NEMA 5-15P plug and a 9 ft (2.74 m) cord—no hard-wiring required.
  • NSF/ANSI 7 compliant and cULus, UL EPH Classified for safe, open-food storage.
Specifications
Model T-43F-HC
Sections / Doors 2 / Solid swing, self-closing
Shelves 6 adjustable PVC-coated wire shelves (20 ⅞″ L × 22 ½″ D)
Exterior dimensions 47″ W × 29 ½″ D × 78 ⅜″ H (cabinet)
83 ⅜″ H on 4″ castors
Holding temperature -10 °F (-23.3 °C)
Refrigerant R290 Hydrocarbon
Compressor 1 HP, bottom mounted
Electrical 115 V / 60 Hz / 1-phase, 9.6 A, NEMA 5-15P
Cord length 9 ft (2.74 m)
Crated weight 410 lb (186 kg)
What our Experts Think  
  • High-capacity 2-section flex-temp freezer: Designed for large-volume commercial kitchens needing one unit that can operate as either a refrigerator or deep freezer depending on demand.
  • Wide operating temperature range: Flexible performance from -10°F to 38°F, making it suitable for frozen storage or chilled holding in a single cabinet.
  • Heavy-duty stainless steel construction: Built with a stainless steel front and durable commercial-grade cabinet materials for long-term kitchen reliability and sanitation.
  • Energy-efficient R290 refrigeration system: Uses modern hydrocarbon refrigerant with zero ozone depletion impact and very low environmental footprint.
  • Factory-balanced cooling performance: Oversized refrigeration system ensures fast temperature recovery and stable internal conditions even under heavy door use.
  • Two solid-door storage design: Dual doors improve organization and reduce cold air loss during frequent access in busy operations.
  • Commercial workflow efficiency: Adjustable shelving and large interior capacity support structured storage for high-turnover inventory.
  • Built for demanding environments: Ideal for restaurants, hotels, and institutional kitchens requiring reliable, flexible cold storage at scale.
                 
Q&A    

Q: What is the True Manufacturing T-49F-FLX-HC?
A: A 2-section SPEC SERIES Flex-Temp reach-in freezer designed for high-volume commercial kitchens that need one unit capable of switching between refrigeration and freezing.

Q: What temperature range does it support?
A: It operates in a wide range from approximately -10°F (-23°C) to 38°F (3.3°C), allowing use as either a freezer or refrigerator depending on settings. 

Q: What refrigerant does it use?
A: It uses R290 hydrocarbon refrigerant, which offers high efficiency and very low environmental impact (zero ozone depletion potential).

Q: What is its construction like?
A: Stainless steel front with durable aluminum interior and heavy-duty insulation designed for long-term commercial performance and energy efficiency.

Q: Who is it best suited for?
A: Restaurants, hotels, commissaries, and commercial kitchens that want flexibility to switch between refrigeration and freezing without buying separate equipment.

               
Maintenance Tips
  • Clean condenser coils every 30–90 days to maintain peak freezing performance and energy efficiency
  • Keep front grille and ventilation areas unobstructed for proper airflow and compressor protection
  • Inspect door gaskets regularly; clean and replace if worn to prevent cold air loss and frost buildup
  • Ensure doors are properly aligned and fully sealing after each use
  • Maintain freezer temperature at 0°F (-18°C) or manufacturer-recommended setting using a calibrated thermometer
  • Minimize door openings to reduce frost accumulation and compressor strain
  • Regularly check defrost system to prevent ice buildup on evaporator coils
  • Clean interior surfaces with mild soap and warm water; avoid abrasive or harsh chemical cleaners
  • Wipe spills immediately to prevent ice formation, odor, and contamination issues
  • Check evaporator fans for smooth operation and unusual noise or vibration
  • Keep drain lines clear to prevent water buildup during defrost cycles
  • Ensure unit is level for proper sealing, drainage, and efficient operation
  • Schedule preventive maintenance at least twice per year to extend equipment lifespan and reliability