The Edan VE-300 Veterinary EKG (#VE-300) includes a built-in thermal printer and a rechargeable lithium battery. It is simple and easy-to-use and works as a single or 3 channel ECG for animals with interpretive analysis included in the form of automatic measurement calculation. It is also extremely portable thanks to a lightweight design and a built-in handle.
3-channel display on 3.5 inch LCD color screen.
Complete digital design.
LCD display waveforms with configurable parameters.
Lead-Off detection and display.
Complete digital filter to avoid baseline drift, AC, and EMG interference.
Automatic ECG parameter measurement.
Veterinary five-lead ECG cable and alligator clips.
AHA/IEC color coding for lead identification.
The baseline is automatically adjustable.
Portable design with built in handle.
Simple, one-button operation.
Well designed touch panel.
Built-in rechargeable Lithium battery and AC/DC supply.
Built-in thermal printer.
High resolution thermal printing.
Capable of directly printing out with external inkjet printer.
Copy mode prints additional copies of the last Auto ECG.
Select your printing format: 1 lead, 3 lead, rhythm lead, or average template.
Waterproof mambrane keyboard.
Input/Output and RS-232 port and Ethernet network capability.
USB Interface for patient data transferring to flash disk.
Input Circuit | Protection from defibrillation. |
---|---|
Lead | Standard 7 leads. |
Acquisition | 7 leads simultaneously. |
A/D Resolution | 12 bits. |
Measurement Range | ±5mVpp. |
Time Constant | ≥3.2s. |
Frequency Response | 0.05Hz ~ 150Hz. |
Calibration Voltage | 1mV ±3%. |
Sensitivity | 2.5, 5, 10, 20 (mm/mV). |
Input Impedance | ≥50m Ω. |
Input Circuit Current | ≥50nA. |
Noise Level | ≥15µVp-p. |
Anti Baseline Drift | Automatic. |
Patient Leakage Current | ≤10µA (220V~240V). |
Patient Auxiliary Current | ≤0.1µA (DC). |
The Edan VE-300 Veterinary EKG (#VE-300) includes a built-in thermal printer and a rechargeable lithium battery. It is simple and easy-to-use and works as a single or 3 channel ECG for animals with interpretive analysis included in the form of automatic measurement calculation. It is also extremely portable thanks to a lightweight design and a built-in handle.
3-channel display on 3.5 inch LCD color screen.
Complete digital design.
LCD display waveforms with configurable parameters.
Lead-Off detection and display.
Complete digital filter to avoid baseline drift, AC, and EMG interference.
Automatic ECG parameter measurement.
Veterinary five-lead ECG cable and alligator clips.
AHA/IEC color coding for lead identification.
The baseline is automatically adjustable.
Portable design with built in handle.
Simple, one-button operation.
Well designed touch panel.
Built-in rechargeable Lithium battery and AC/DC supply.
Built-in thermal printer.
High resolution thermal printing.
Capable of directly printing out with external inkjet printer.
Copy mode prints additional copies of the last Auto ECG.
Select your printing format: 1 lead, 3 lead, rhythm lead, or average template.
Waterproof mambrane keyboard.
Input/Output and RS-232 port and Ethernet network capability.
USB Interface for patient data transferring to flash disk.
Input Circuit | Protection from defibrillation. |
---|---|
Lead | Standard 7 leads. |
Acquisition | 7 leads simultaneously. |
A/D Resolution | 12 bits. |
Measurement Range | ±5mVpp. |
Time Constant | ≥3.2s. |
Frequency Response | 0.05Hz ~ 150Hz. |
Calibration Voltage | 1mV ±3%. |
Sensitivity | 2.5, 5, 10, 20 (mm/mV). |
Input Impedance | ≥50m Ω. |
Input Circuit Current | ≥50nA. |
Noise Level | ≥15µVp-p. |
Anti Baseline Drift | Automatic. |
Patient Leakage Current | ≤10µA (220V~240V). |
Patient Auxiliary Current | ≤0.1µA (DC). |