Fujitsu 12.5kW Inverter Ducted System 3 Phase Set - ARTG45LHTB

by FUJITSU
SKU ARTG45LHTB
Save 6% Save 6%
Original price $5,150.00
Original price $5,150.00 - Original price $5,150.00
Original price $5,150.00
Current price $4,841.99
$4,841.99 - $4,841.99
Current price $4,841.99
  • CLEARANCE SALE.

  • ITEMS LEFT.

  • PEOPLE are also watching that product.


Fujitsu 12.5kW Inverter Ducted System 3 Phase Set - ARTG45LHTB

Experience optimal climate control with the Fujitsu 12.5kW Inverter Ducted Air Conditioner System, featuring the ARTG45LHTB indoor unit and AOTG45LATT outdoor unit. This system is designed to efficiently cool and heat medium to large spaces, offering 12.5 kW of cooling capacity and 14.0 kW of heating capacity. It is ideal for both residential and commercial applications, ensuring year-round comfort with its advanced features.

The system includes a wired backlit controller (UTY-RVNYN) for easy operation and precise temperature management. Operating on three-phase power (415V, 50Hz), it provides robust performance suitable for demanding environments. With an extensive operating temperature range from -15°C to 46°C for cooling and -15°C to 24°C for heating, it adapts to varying climate conditions seamlessly.

  • Powerful Performance: 12.5 kW cooling and 14.0 kW heating capacity.

  • Energy Efficiency: E.E.R. of 3.27 for cooling and C.O.P. of 3.81 for heating.

  • Quiet Operation: Indoor unit sound pressure level as low as 43 dBA (high fan mode).

  • Automatic Air Flow Adjustment: Ensures optimal airflow distribution.

  • Compact Design: Lightweight indoor unit with dimensions of 425 x 1250 x 490 mm and weighing 54 kg.

  • Environmentally Friendly: Uses R410A refrigerant with minimal environmental impact.

Model No. – Indoor ARTG45LHTB
Model No. – Outdoor AOTG45LATT
Reverse Cycle System Yes
Cooling Capacity (Watts) 12,500
Cooling Capacity (BTU/h) 42,700
Range (Watts) 5,700 – 14,000
Range (BTU/h) 19,500 – 47,800
Heating Capacity (Watts) 14,000
Heating Capacity (BTU/h) 47,800
Range (Watts) 6,000 – 16,200
Range (BTU/h) 29,500 – 55,300
Power Supply (Volts) 415
Phase-Frequency (Ph – Hz) 3 – 50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 5.5
Running Current, Range (Amps) Max 11.0
Input, Cooling (Watts) 3,820
Input, Range (Watts) Max 6,370
Running Current, Heating (Amps) 5.3
Running Current, Range (Amps) Max 11.0
Input, Heating (Watts) 3,670
Input, Range (Watts) Max 6,370
Moisture Removal (l/hr) 1
E.E.R. – Cooling 3.27
C.O.P. – Heating 3.81
Fan Speed 4
Air Circulation, High (l/s) 903
Compressor Type Twin Rotary
Dimensions – Inside Unit (HxWxD mm) 425 x 1,250 x 490
Weight – Inside Unit (kg) 54
Dimensions – Outside Unit (HxWxD mm) 1,290 x 900 x 330
Weight – Outside Unit (kg) 104
I.U. Sound Pressure Level (dBA@1mtr) 43
O.U. Sound Pressure Level (dBA@1mtr) 54
O.U. Sound Power Level (dBA) 68
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 15.88
Connection Pipe Sizes, Liquid (mm) 9.52
Pre Charged Length (Metre) 30
Minimum Pipe Length (Metre) 5
Maximum Pipe Length (Metre) 75
Maximum Pipe Height (Metre) 30
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling Degrees C -15 to 46
Outdoor operating Temp, Heating Degrees C -15 to 24

 

 

 

Fujitsu 12.5kW Inverter Ducted System 3 Phase Set - ARTG45LHTB

Experience optimal climate control with the Fujitsu 12.5kW Inverter Ducted Air Conditioner System, featuring the ARTG45LHTB indoor unit and AOTG45LATT outdoor unit. This system is designed to efficiently cool and heat medium to large spaces, offering 12.5 kW of cooling capacity and 14.0 kW of heating capacity. It is ideal for both residential and commercial applications, ensuring year-round comfort with its advanced features.

The system includes a wired backlit controller (UTY-RVNYN) for easy operation and precise temperature management. Operating on three-phase power (415V, 50Hz), it provides robust performance suitable for demanding environments. With an extensive operating temperature range from -15°C to 46°C for cooling and -15°C to 24°C for heating, it adapts to varying climate conditions seamlessly.

  • Powerful Performance: 12.5 kW cooling and 14.0 kW heating capacity.

  • Energy Efficiency: E.E.R. of 3.27 for cooling and C.O.P. of 3.81 for heating.

  • Quiet Operation: Indoor unit sound pressure level as low as 43 dBA (high fan mode).

  • Automatic Air Flow Adjustment: Ensures optimal airflow distribution.

  • Compact Design: Lightweight indoor unit with dimensions of 425 x 1250 x 490 mm and weighing 54 kg.

  • Environmentally Friendly: Uses R410A refrigerant with minimal environmental impact.

Model No. – Indoor ARTG45LHTB
Model No. – Outdoor AOTG45LATT
Reverse Cycle System Yes
Cooling Capacity (Watts) 12,500
Cooling Capacity (BTU/h) 42,700
Range (Watts) 5,700 – 14,000
Range (BTU/h) 19,500 – 47,800
Heating Capacity (Watts) 14,000
Heating Capacity (BTU/h) 47,800
Range (Watts) 6,000 – 16,200
Range (BTU/h) 29,500 – 55,300
Power Supply (Volts) 415
Phase-Frequency (Ph – Hz) 3 – 50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 5.5
Running Current, Range (Amps) Max 11.0
Input, Cooling (Watts) 3,820
Input, Range (Watts) Max 6,370
Running Current, Heating (Amps) 5.3
Running Current, Range (Amps) Max 11.0
Input, Heating (Watts) 3,670
Input, Range (Watts) Max 6,370
Moisture Removal (l/hr) 1
E.E.R. – Cooling 3.27
C.O.P. – Heating 3.81
Fan Speed 4
Air Circulation, High (l/s) 903
Compressor Type Twin Rotary
Dimensions – Inside Unit (HxWxD mm) 425 x 1,250 x 490
Weight – Inside Unit (kg) 54
Dimensions – Outside Unit (HxWxD mm) 1,290 x 900 x 330
Weight – Outside Unit (kg) 104
I.U. Sound Pressure Level (dBA@1mtr) 43
O.U. Sound Pressure Level (dBA@1mtr) 54
O.U. Sound Power Level (dBA) 68
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 15.88
Connection Pipe Sizes, Liquid (mm) 9.52
Pre Charged Length (Metre) 30
Minimum Pipe Length (Metre) 5
Maximum Pipe Length (Metre) 75
Maximum Pipe Height (Metre) 30
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling Degrees C -15 to 46
Outdoor operating Temp, Heating Degrees C -15 to 24