Fujitsu 14kW Inverter Ducted Air Conditioner System High Static SET - ARTG54LHTC

by FUJITSU
SKU ARTG54LHTC
Save 6% Save 6%
Original price $5,495.00
Original price $5,495.00 - Original price $5,495.00
Original price $5,495.00
Current price $5,165.99
$5,165.99 - $5,165.99
Current price $5,165.99
  • CLEARANCE SALE.

  • ITEMS LEFT.

  • PEOPLE are also watching that product.


Fujitsu 14kW Inverter Ducted Air Conditioner System High Static SET - ARTG54LHTC

Experience superior climate control with the Fujitsu SET-ARTG54LHTC 14.0kW Inverter Ducted Air Conditioner System, designed for high static pressure applications. This powerful single-phase system, comprising the indoor model ARTG54LHTC and the outdoor model AOTG54LCTL, delivers exceptional cooling and heating performance to ensure comfort throughout the year.

The system is equipped with a backlit controller (UTY-RVNYN) that simplifies operation, making it easy to adjust settings for optimal comfort. With a cooling capacity of 14.0kW and a heating capacity of 16.0kW, this ducted air conditioner is ideal for large residential or commercial spaces.

  • Powerful Cooling and Heating: 14.0kW cooling capacity and 16.0kW heating capacity for year-round comfort.

  • High Static Pressure: Suitable for applications requiring high static pressure, ensuring consistent airflow throughout your space.

  • Inverter Technology: Enhances energy efficiency and provides precise temperature control.

  • Backlit Controller (UTY-RVNYN): User-friendly interface with backlit display for easy operation, even in low light conditions.

  • Single Phase Operation: Simplifies installation and compatibility with standard electrical systems.

Model No. – Indoor ARTG54LHTC
Model No. – Outdoor AOTG54LCTL
Reverse Cycle System Yes
Cooling Capacity (Watts) 14,000
Cooling Capacity (BTU/h) 47,800
Range (Watts) 6,200 – 15,200
Range (BTU/h) 21,200 – 51,900
Heating Capacity (Watts) 16,000
Heating Capacity (BTU/h) 54,600
Range (Watts) 6,200 – 18,000
Range (BTU/h) 21,200 – 61,500
Power Supply (Volts) 240
Phase-Frequency (Ph – Hz) 1 – 50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 18.4
Running Current, Range (Amps) Max: 23.5
Input, Cooling (Watts) 4,400
Input, Range (Watts) Max: 5,630
Running Current, Heating (Amps) 18.3
Running Current, Range (Amps) Max: 23.5
Input, Heating (Watts) 4,370
Input, Range (Watts) Max 5,630
Moisture Removal (l/hr) 1.5
E.E.R. – Cooling 3.18
C.O.P. – Heating 3.66
Fan Speed 4
Air Circulation, High (l/s) 986
Compressor Type DC Rotary
Dimensions – Inside Unit (HxWxD mm) 425 x 1,250 x 490
Weight – Inside Unit (kg) 54
Dimensions – Outside Unit (HxWxD mm) 1,290 x 900 x 330
Weight – Outside Unit (kg) 93
I.U. Sound Pressure Level (dBA@1mtr) 45
O.U. Sound Pressure Level (dBA@1mtr) 55
O.U. Sound Power Level (dBA) 70
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 15.88
Connection Pipe Sizes, Liquid (mm) 9.52
Pre Charged Length (Metre) 30
Minimum Pipe Length (Metre) 5
Maximum Pipe Length (Metre) 75
Maximum Pipe Height (Metre) 30
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling ℃ -15 to 46
Outdoor operating Temp, Heating ℃ -15 to 24

 

 

 

Fujitsu 14kW Inverter Ducted Air Conditioner System High Static SET - ARTG54LHTC

Experience superior climate control with the Fujitsu SET-ARTG54LHTC 14.0kW Inverter Ducted Air Conditioner System, designed for high static pressure applications. This powerful single-phase system, comprising the indoor model ARTG54LHTC and the outdoor model AOTG54LCTL, delivers exceptional cooling and heating performance to ensure comfort throughout the year.

The system is equipped with a backlit controller (UTY-RVNYN) that simplifies operation, making it easy to adjust settings for optimal comfort. With a cooling capacity of 14.0kW and a heating capacity of 16.0kW, this ducted air conditioner is ideal for large residential or commercial spaces.

  • Powerful Cooling and Heating: 14.0kW cooling capacity and 16.0kW heating capacity for year-round comfort.

  • High Static Pressure: Suitable for applications requiring high static pressure, ensuring consistent airflow throughout your space.

  • Inverter Technology: Enhances energy efficiency and provides precise temperature control.

  • Backlit Controller (UTY-RVNYN): User-friendly interface with backlit display for easy operation, even in low light conditions.

  • Single Phase Operation: Simplifies installation and compatibility with standard electrical systems.

Model No. – Indoor ARTG54LHTC
Model No. – Outdoor AOTG54LCTL
Reverse Cycle System Yes
Cooling Capacity (Watts) 14,000
Cooling Capacity (BTU/h) 47,800
Range (Watts) 6,200 – 15,200
Range (BTU/h) 21,200 – 51,900
Heating Capacity (Watts) 16,000
Heating Capacity (BTU/h) 54,600
Range (Watts) 6,200 – 18,000
Range (BTU/h) 21,200 – 61,500
Power Supply (Volts) 240
Phase-Frequency (Ph – Hz) 1 – 50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 18.4
Running Current, Range (Amps) Max: 23.5
Input, Cooling (Watts) 4,400
Input, Range (Watts) Max: 5,630
Running Current, Heating (Amps) 18.3
Running Current, Range (Amps) Max: 23.5
Input, Heating (Watts) 4,370
Input, Range (Watts) Max 5,630
Moisture Removal (l/hr) 1.5
E.E.R. – Cooling 3.18
C.O.P. – Heating 3.66
Fan Speed 4
Air Circulation, High (l/s) 986
Compressor Type DC Rotary
Dimensions – Inside Unit (HxWxD mm) 425 x 1,250 x 490
Weight – Inside Unit (kg) 54
Dimensions – Outside Unit (HxWxD mm) 1,290 x 900 x 330
Weight – Outside Unit (kg) 93
I.U. Sound Pressure Level (dBA@1mtr) 45
O.U. Sound Pressure Level (dBA@1mtr) 55
O.U. Sound Power Level (dBA) 70
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 15.88
Connection Pipe Sizes, Liquid (mm) 9.52
Pre Charged Length (Metre) 30
Minimum Pipe Length (Metre) 5
Maximum Pipe Length (Metre) 75
Maximum Pipe Height (Metre) 30
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling ℃ -15 to 46
Outdoor operating Temp, Heating ℃ -15 to 24