Engrave on wood, leather, acrylics, and many other materials. Cut thin and soft woods like Balsa, Basswood, and many other types of materials like foam, paper, cloth and acrylics.
The Axiom CNC laser by J Tech Photonics raises the bar in CNC accessory lasers. Precision laser trimmed regulators for constant current to the laser, 0.01 tuning resolution, digital isolation, soft start, ESD protection, current limiting, and the list goes on. The US Federal Government has a list of things that are required for operating these high power class 4 lasers. They might seem trivial, but they could save your eyesight!
Safety Features
Current Source Range | 0 – 2.5 Amps |
Current Limit Jumper Settings | 0.5, 1.0, 1.5, 2.0, 2.5 Amps |
Compliance Voltage w/12V Adapter | 8 volts |
Current Resolution | 0.1% |
Current Adjustment | Analog Trim Pot |
Current Range Accuracy | Always greater than limit, no more than 15% |
Laser Diode Protection | Soft Start, Reverse Voltage, Current Limit, Thermal Shutdown |
AC Adapter Input Voltage | 100 – 240 VAC |
Control Signal Digital Isolation Voltage | 4,500 Vrms |
Min. Control Signal "Turn On" Voltage | 2.8 Volts |
Control Signal Max. Voltage | 36 Volts |
Control Signal Max. Current | 50 mA |
Control Signal Max. Frequency | 5 kHz |
Connectors | Screw Terminal and Molex Mini-Fit Jr™ Connectors |
Operating Temperature | 0 to 40 °C |
Storage Temperature | -40 to 70 °C |
Dimensions | 3.6″ x 2.2″ |
Engrave on wood, leather, acrylics, and many other materials. Cut thin and soft woods like Balsa, Basswood, and many other types of materials like foam, paper, cloth and acrylics.
The Axiom CNC laser by J Tech Photonics raises the bar in CNC accessory lasers. Precision laser trimmed regulators for constant current to the laser, 0.01 tuning resolution, digital isolation, soft start, ESD protection, current limiting, and the list goes on. The US Federal Government has a list of things that are required for operating these high power class 4 lasers. They might seem trivial, but they could save your eyesight!
Safety Features
Current Source Range | 0 – 2.5 Amps |
Current Limit Jumper Settings | 0.5, 1.0, 1.5, 2.0, 2.5 Amps |
Compliance Voltage w/12V Adapter | 8 volts |
Current Resolution | 0.1% |
Current Adjustment | Analog Trim Pot |
Current Range Accuracy | Always greater than limit, no more than 15% |
Laser Diode Protection | Soft Start, Reverse Voltage, Current Limit, Thermal Shutdown |
AC Adapter Input Voltage | 100 – 240 VAC |
Control Signal Digital Isolation Voltage | 4,500 Vrms |
Min. Control Signal "Turn On" Voltage | 2.8 Volts |
Control Signal Max. Voltage | 36 Volts |
Control Signal Max. Current | 50 mA |
Control Signal Max. Frequency | 5 kHz |
Connectors | Screw Terminal and Molex Mini-Fit Jr™ Connectors |
Operating Temperature | 0 to 40 °C |
Storage Temperature | -40 to 70 °C |