icon Fujitsu 10.5kW Ducted Air conditioner System 3 Phase - ARTG36LHTB | Backyard Provider Skip to content
Warranty

Manufacturer's warranty on most items

Great Discounts

Your favorite products on sale

 
Expert Assistance

Need help? Give us a call at 888 575-2099

Free Shipping

We offer free shipping

Fujitsu 10.5kW Ducted Air conditioner System 3 Phase - ARTG36LHTB

by FUJITSU
SKU ARTG36LHTB
Save 6% Save 6%
Original price $4,464.00
Original price $4,464.00 - Original price $4,464.00
Original price $4,464.00
Current price $4,196.99
$4,196.99 - $4,196.99
Current price $4,196.99
  • CLEARANCE SALE.

  • ITEMS LEFT.

  • PEOPLE are also watching that product.


Fujitsu 10.5kW Ducted Air conditioner System 3 Phase  - ARTG36LHTB

Ensure year-round comfort with the Fujitsu 10.5kW Inverter Ducted Air Conditioner System, comprising the ARTG36LHTB indoor unit and AOTG36LATT outdoor unit. Designed for efficiency and reliability, this system offers 10.5 kW of cooling power and 12.1 kW for heating, making it suitable for medium-sized spaces in both residential and commercial settings.

The system features a wired backlit controller (UTY-RVNYN) for intuitive operation and precise temperature control. Operating on three-phase power (415V, 50Hz), it delivers robust performance even in demanding environments. With an extensive operating temperature range from -15°C to 46°C for cooling and -15°C to 24°C for heating, it adapts seamlessly to varying climate conditions.

  • Powerful Performance: 10.5 kW cooling and 12.1 kW heating capacity.

  • Energy Efficiency: E.E.R. of 3.3 for cooling and C.O.P. of 3.67 for heating.

  • Quiet Operation: Indoor unit sound pressure level as low as 41 dBA (high fan mode).

  • Automatic Air Flow Adjustment: Ensures optimal airflow distribution.

  • Compact Design: Lightweight indoor unit with dimensions of 400 x 1050 x 500 mm and weighing 39 kg.

  • Environmentally Friendly: Uses R410A refrigerant with minimal environmental impact.

Model No. – Indoor ARTG36LHTB
Model No. – Outdoor AOTG36LATT
Reverse Cycle System Yes
Cooling Capacity (Watts) 10,500
Cooling Capacity (BTU/h) 35,800
Range (Watts) 5,000 – 11,400
Range (BTU/h) 17,100 – 38,900
Heating Capacity (Watts) 12,100
Heating Capacity (BTU/h) 41,300
Range (Watts) 5,100 – 14,000
Range (BTU/h) 17,400 – 47,800
Power Supply (Volts) 415
Phase-Frequency (Ph – Hz) 3 – 50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 4.6
Running Current, Range (Amps) Max 9.0
Input, Cooling (Watts) 3,180
Input, Range (Watts) Max 5,630
Running Current, Heating (Amps) 4.8
Running Current, Range (Amps) Max 9.0
Input, Heating (Watts) 3,300
Input, Range (Watts) Max 5,630
Moisture Removal (l/hr) 1.5
E.E.R. – Cooling 3.3
C.O.P. – Heating 3.67
Fan Speed 4
Air Circulation, High (l/s) 695
Compressor Type DC Rotary
Dimensions – Inside Unit (HxWxD mm) 400 x 1,050 x 500
Weight – Inside Unit (kg) 39
Dimensions – Outside Unit (HxWxD mm) 1,290 x 900 x 330
Weight – Outside Unit (kg) 104
I.U. Sound Pressure Level (dBA@1mtr) 41
O.U. Sound Pressure Level (dBA@1mtr) 51
O.U. Sound Power Level (dBA) 67
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 15.88
Connection Pipe Sizes, Liquid (mm) 9.52
Pre Charged Length (Metre) 30
Minimum Pipe Length (Metre) 5
Maximum Pipe Length (Metre) 75
Maximum Pipe Height (Metre) 30
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling Degrees C -15 to 46
Outdoor operating Temp, Heating Degrees C -15 to 24

 

 

 

Fujitsu 10.5kW Ducted Air conditioner System 3 Phase  - ARTG36LHTB

Ensure year-round comfort with the Fujitsu 10.5kW Inverter Ducted Air Conditioner System, comprising the ARTG36LHTB indoor unit and AOTG36LATT outdoor unit. Designed for efficiency and reliability, this system offers 10.5 kW of cooling power and 12.1 kW for heating, making it suitable for medium-sized spaces in both residential and commercial settings.

The system features a wired backlit controller (UTY-RVNYN) for intuitive operation and precise temperature control. Operating on three-phase power (415V, 50Hz), it delivers robust performance even in demanding environments. With an extensive operating temperature range from -15°C to 46°C for cooling and -15°C to 24°C for heating, it adapts seamlessly to varying climate conditions.

  • Powerful Performance: 10.5 kW cooling and 12.1 kW heating capacity.

  • Energy Efficiency: E.E.R. of 3.3 for cooling and C.O.P. of 3.67 for heating.

  • Quiet Operation: Indoor unit sound pressure level as low as 41 dBA (high fan mode).

  • Automatic Air Flow Adjustment: Ensures optimal airflow distribution.

  • Compact Design: Lightweight indoor unit with dimensions of 400 x 1050 x 500 mm and weighing 39 kg.

  • Environmentally Friendly: Uses R410A refrigerant with minimal environmental impact.

Model No. – Indoor ARTG36LHTB
Model No. – Outdoor AOTG36LATT
Reverse Cycle System Yes
Cooling Capacity (Watts) 10,500
Cooling Capacity (BTU/h) 35,800
Range (Watts) 5,000 – 11,400
Range (BTU/h) 17,100 – 38,900
Heating Capacity (Watts) 12,100
Heating Capacity (BTU/h) 41,300
Range (Watts) 5,100 – 14,000
Range (BTU/h) 17,400 – 47,800
Power Supply (Volts) 415
Phase-Frequency (Ph – Hz) 3 – 50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 4.6
Running Current, Range (Amps) Max 9.0
Input, Cooling (Watts) 3,180
Input, Range (Watts) Max 5,630
Running Current, Heating (Amps) 4.8
Running Current, Range (Amps) Max 9.0
Input, Heating (Watts) 3,300
Input, Range (Watts) Max 5,630
Moisture Removal (l/hr) 1.5
E.E.R. – Cooling 3.3
C.O.P. – Heating 3.67
Fan Speed 4
Air Circulation, High (l/s) 695
Compressor Type DC Rotary
Dimensions – Inside Unit (HxWxD mm) 400 x 1,050 x 500
Weight – Inside Unit (kg) 39
Dimensions – Outside Unit (HxWxD mm) 1,290 x 900 x 330
Weight – Outside Unit (kg) 104
I.U. Sound Pressure Level (dBA@1mtr) 41
O.U. Sound Pressure Level (dBA@1mtr) 51
O.U. Sound Power Level (dBA) 67
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 15.88
Connection Pipe Sizes, Liquid (mm) 9.52
Pre Charged Length (Metre) 30
Minimum Pipe Length (Metre) 5
Maximum Pipe Length (Metre) 75
Maximum Pipe Height (Metre) 30
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling Degrees C -15 to 46
Outdoor operating Temp, Heating Degrees C -15 to 24