The Fujitsu 4.2kW Inverter Floor Console System Set - AGTG14KVCA offers efficient heating and cooling capabilities suitable for both residential and commercial environments. With a cooling capacity ranging from 0.9 kW to 5.2 kW and a heating capacity from 0.9 kW to 6.5 kW, it provides flexibility in maintaining comfortable indoor temperatures year-round. The system operates on a standard 240V power supply and single-phase configuration, making it compatible with typical household electrical setups.
Key features include an Apple-Catechin Filter and Long-Life Ion Deodorization Filter, which enhance air quality by reducing odors and capturing airborne particles. The system utilizes R32 refrigerant, known for its lower environmental impact compared to older refrigerants, contributing to energy efficiency and reduced greenhouse gas emissions.
Cooling and Heating Capacity: Provides 4.5 kW of cooling capacity and 3.5 kW of heating capacity, suitable for maintaining comfortable indoor temperatures year-round.
Energy Efficiency: Boasts high energy efficiency with an EER (Energy Efficiency Ratio) of 4.7 for cooling and a COP (Coefficient of Performance) of 4.27 for heating, ensuring cost-effective operation.
Environmental Friendliness: Uses R32 refrigerant, which has a lower global warming potential (GWP), contributing to reduced environmental impact compared to traditional refrigerants.
Advanced Air Quality Features: Equipped with an Apple-Catechin filter and Long-Life Ion Deodorization filter, effectively capturing dust particles, allergens, and neutralizing odors, thereby improving indoor air quality.
Indoor unit | AGTG14KVCA |
---|---|
Outdoor unit | AOTG14KVCA |
Operation Type | Reverse Cycle |
Power Source V/Ph/Hz | 240 / 1 / 50 |
Cooling Capacity kW (Rated (Min – Max)) | 4.20 (0.9 – 5.2) |
Heating Capacity kW (Rated (Min – Max)) | 5.20 (0.9 – 6.5) |
Input Power Cooling kW (Rated (Max)) | 1.1 (2.12) |
Input Power Heating kW (Rated (Max)) | 1.41 (2.15) |
EER Cooling kW/kW | 3.8 |
COP Heating kW/kW | 3.7 |
Star Rating Cooling (0-10) (Hot / Average / Cold) | 4 / 4 / 4 |
Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 2.5 / 2 |
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.975 / 5.579 / 5.933 |
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.669 / 4.111 / 3.546 |
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 6.754 / 7.227 / 8.349 |
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.678 / 4.34 / 3.854 |
Running Current amps (Cooling / Heating) | 4.8 / 6.1 |
Moisture Removal l/hr | 2.1 |
Indoor Sound Pressure Cooling dBA (High / Quiet) | 44 / 22 |
Indoor Sound Pressure Heating dBA (High / Quiet) | 43 / 22 |
Outdoor Sound Pressure dBA (Cooling / Heating) | 47 / 49 |
Outdoor Sound Power dBA | 62 |
Air Circulation (Indoor – High Fan) Cooling l/sec | 181 |
Air Circulation (Indoor – High Fan) Heating l/sec | 181 |
Indoor Unit Dimensions mm (Height x Width x Depth) | 600 x 740 x 200 |
Indoor Unit Weight kg | 14.00 |
Outdoor Unit Dimensions mm (Height x Width x Depth) | 632 x 799 x 290 |
Outdoor Unit Weight kg | 38.00 |
Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 |
Pipe Length m (Max (Precharged)) | 20 (15) |
Max Height Difference m | 15 |
Operation Range Cooling °CDB (Min to Max) | -10 to 46 |
Operation Range Heating °CDB (Min to Max) | -15 to 24 |
Refrigerant Type | R32 |
The Fujitsu 4.2kW Inverter Floor Console System Set - AGTG14KVCA offers efficient heating and cooling capabilities suitable for both residential and commercial environments. With a cooling capacity ranging from 0.9 kW to 5.2 kW and a heating capacity from 0.9 kW to 6.5 kW, it provides flexibility in maintaining comfortable indoor temperatures year-round. The system operates on a standard 240V power supply and single-phase configuration, making it compatible with typical household electrical setups.
Key features include an Apple-Catechin Filter and Long-Life Ion Deodorization Filter, which enhance air quality by reducing odors and capturing airborne particles. The system utilizes R32 refrigerant, known for its lower environmental impact compared to older refrigerants, contributing to energy efficiency and reduced greenhouse gas emissions.
Cooling and Heating Capacity: Provides 4.5 kW of cooling capacity and 3.5 kW of heating capacity, suitable for maintaining comfortable indoor temperatures year-round.
Energy Efficiency: Boasts high energy efficiency with an EER (Energy Efficiency Ratio) of 4.7 for cooling and a COP (Coefficient of Performance) of 4.27 for heating, ensuring cost-effective operation.
Environmental Friendliness: Uses R32 refrigerant, which has a lower global warming potential (GWP), contributing to reduced environmental impact compared to traditional refrigerants.
Advanced Air Quality Features: Equipped with an Apple-Catechin filter and Long-Life Ion Deodorization filter, effectively capturing dust particles, allergens, and neutralizing odors, thereby improving indoor air quality.
Indoor unit | AGTG14KVCA |
---|---|
Outdoor unit | AOTG14KVCA |
Operation Type | Reverse Cycle |
Power Source V/Ph/Hz | 240 / 1 / 50 |
Cooling Capacity kW (Rated (Min – Max)) | 4.20 (0.9 – 5.2) |
Heating Capacity kW (Rated (Min – Max)) | 5.20 (0.9 – 6.5) |
Input Power Cooling kW (Rated (Max)) | 1.1 (2.12) |
Input Power Heating kW (Rated (Max)) | 1.41 (2.15) |
EER Cooling kW/kW | 3.8 |
COP Heating kW/kW | 3.7 |
Star Rating Cooling (0-10) (Hot / Average / Cold) | 4 / 4 / 4 |
Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 2.5 / 2 |
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.975 / 5.579 / 5.933 |
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.669 / 4.111 / 3.546 |
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 6.754 / 7.227 / 8.349 |
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.678 / 4.34 / 3.854 |
Running Current amps (Cooling / Heating) | 4.8 / 6.1 |
Moisture Removal l/hr | 2.1 |
Indoor Sound Pressure Cooling dBA (High / Quiet) | 44 / 22 |
Indoor Sound Pressure Heating dBA (High / Quiet) | 43 / 22 |
Outdoor Sound Pressure dBA (Cooling / Heating) | 47 / 49 |
Outdoor Sound Power dBA | 62 |
Air Circulation (Indoor – High Fan) Cooling l/sec | 181 |
Air Circulation (Indoor – High Fan) Heating l/sec | 181 |
Indoor Unit Dimensions mm (Height x Width x Depth) | 600 x 740 x 200 |
Indoor Unit Weight kg | 14.00 |
Outdoor Unit Dimensions mm (Height x Width x Depth) | 632 x 799 x 290 |
Outdoor Unit Weight kg | 38.00 |
Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 |
Pipe Length m (Max (Precharged)) | 20 (15) |
Max Height Difference m | 15 |
Operation Range Cooling °CDB (Min to Max) | -10 to 46 |
Operation Range Heating °CDB (Min to Max) | -15 to 24 |
Refrigerant Type | R32 |