Skip to product information
1 of 10

Goodman

GOODMAN 3 Ton 13.4 SEER2 96% AFUE 80,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9S960803BN

GOODMAN 3 Ton 13.4 SEER2 96% AFUE 80,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9S960803BN

review stars 1 Review

5% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $3,856.00 Sale price $3,663.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$28.99

$70.00

$66.99

Add-Ons Bundle

$30.00

$28.99

$70.00

$66.99

Bundle Offer

$100.00

$95.98

Recently Viewed

GOODMAN 3 Ton 13.4 SEER2 96% AFUE 80,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow -  AQ-GR9S960803BN

The ACiQ AQ-GLXS3BN3610 is a cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the AQ-GLXS3BN3610 is an inexpensive condenser to cool your home when paired with an AC coil.The ACiQ AQ-GLXS3BN3610 is a cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the AQ-GLXS3BN3610 is an inexpensive condenser to cool your home when paired with an AC coil.

Features
  • Ideal size to cover a medium-sized house
  • 3 ton, 13.4 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Low sound output
  • Fully charged for up to 15' of line set
  • Factory-installed filter drier
What our Experts Think
  • High-Capacity High-Efficiency System: Combines a 3-ton R32 air conditioner with a 96% AFUE, 80,000 BTU gas furnace, delivering strong whole-home comfort with a focus on energy savings.
  • Premium Heating Efficiency: The 96% AFUE furnace significantly reduces fuel waste, making it ideal for lowering winter heating costs in colder regions.
  • Reliable Cooling Performance: The 13.4 SEER2 rating provides steady, cost-effective cooling for larger residential spaces.
  • Powerful Heating Output: The 80,000 BTU furnace ensures consistent warmth for larger homes or areas with higher heat demand.
  • Modern R32 Refrigerant System: Uses R32 refrigerant, supporting improved efficiency potential and reduced environmental impact compared to older refrigerants.
  • Upflow Installation Design: Built for vertical (upflow) setups, suitable for basements, utility rooms, closets, and standard HVAC configurations.
  • Balanced Efficiency + Power: A strong combination of high-efficiency heating and dependable cooling capacity, making it a well-rounded premium residential system.
Q&A

Q: What size home is this Goodman 3 Ton HVAC system designed for?
A: A 3-ton system is typically suited for medium-sized homes, depending on insulation, climate, ceiling height, and layout. A proper Manual J load calculation is recommended for correct sizing.

Q: What efficiency ratings does this system offer?
A: This system pairs a 13.4 SEER2 R-32 air conditioner with a high-efficiency 96% AFUE gas furnace for strong cooling performance and efficient heating.

Q: What is the furnace heating capacity?
A: The furnace is rated at 80,000 BTU input, delivering about 76,800 BTU of usable heat at 96% efficiency.

Q: Does this system use R-32 refrigerant?
A: Yes. The outdoor condenser uses R-32 refrigerant, a modern low-GWP refrigerant designed to meet current environmental standards.

Q: Is this furnace compatible with upflow installation?
A: Yes. The GR9S960803BN furnace supports upflow and horizontal installation, making it flexible for basements, closets, and utility spaces.

Q: What type of blower motor does it include?
A: It includes a 9-speed ECM blower motor that improves airflow control, efficiency, and quiet operation compared to traditional single-speed motors.

Q: Can this furnace be converted to propane (LP)?
A: Yes. It is factory-set for natural gas but can be converted to propane using an optional LP conversion kit.

Maintenance Tips
  • Replace or clean air filter every 1–3 months to maintain strong airflow, efficiency, and indoor air quality.
  • Keep outdoor condenser unit clear of debris and ensure at least 2 feet of clearance for proper airflow.
  • Schedule professional HVAC maintenance twice yearly—before cooling and heating seasons.
  • Inspect and clean supply and return vents regularly to ensure balanced airflow and comfort.
  • Check condensate drain line periodically to prevent clogs, leaks, and water damage.
  • Verify thermostat operation and settings to ensure accurate temperature control and energy savings.
  • Monitor for unusual noises, odors, or performance changes and address issues early.
  • Have a licensed technician inspect burners, heat exchanger, venting, and safety controls annually.
  • Ensure refrigerant charge and electrical components are checked for optimal cooling performance.
  • Maintain proper home insulation and seal air leaks to reduce system workload and improve efficiency.