Skip to product information
1 of 10

Actron Air

ActronAir Bulkhead BRE-035BS 3.5kW Indoor Unit Only - BRE-035BS

ActronAir Bulkhead BRE-035BS 3.5kW Indoor Unit Only - BRE-035BS

review stars 1 Review

5% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $827.00 Sale price $785.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$28.99

$70.00

$66.99

Add-Ons Bundle

$30.00

$28.99

$70.00

$66.99

Bundle Offer

$100.00

$95.98

Recently Viewed

ActronAir Bulkhead BRE-035BS 3.5kW Indoor Unit Only - BRE-035BS

The ActronAir Bulkhead BRE-035BS 3.5kW indoor unit is designed for seamless integration and efficient climate control in compact spaces. With its sleek design and powerful performance, this unit offers reliable cooling and heating solutions. Ideal for residential or light commercial applications, it ensures comfort with minimal noise and maximum efficiency. Perfect for those seeking discreet and effective indoor climate management.

What our Experts Think
  • Low-profile ceiling solution: The ActronAir BRE-035BS is a 3.5 kW bulkhead indoor unit, designed to sit discreetly in ceiling cavities, delivering conditioned air through a slim linear grille for a clean architectural finish.Ā 
  • Ideal for small to medium rooms: Typically suited for bedrooms, small living areas, or offices, providing efficient heating and cooling without visible wall-mounted hardware.
  • Quiet, comfort-focused operation: Engineered for low noise levels (~30–35 dBA range), making it suitable for quiet environments like bedrooms or study spaces.
  • Efficient airflow design: Delivers up to ~170 L/s airflow (high setting) with multi-speed fan control for balanced temperature distribution across compact zones.
  • Integrated condensate management: Includes a built-in drain pump, allowing flexible installation even where gravity drainage is difficult—important for ceiling-mounted systems.
  • Flexible installation features: Supports bottom or rear return air configurations, giving installers adaptability for different ceiling layouts and renovations.
  • Smart multi-system compatibility: Designed to integrate with ActronAir MultiElite outdoor systems, enabling multi-room zoning from a single outdoor unit setup.
  • Durable, serviceable build: Includes hydrophilic coil protection and accessible service panels, improving longevity and maintenance efficiency in real-world installations.

Q&A

Q1: What is this unit used for?
A: The BRE-035BS is a bulkhead (concealed ducted) indoor unit, designed to be installed in ceiling cavities for discreet air conditioning in bedrooms, living rooms, or small offices.

Q2: What is the cooling and heating capacity?
A: It provides approximately 3.5 kW cooling and 3.8 kW heating, suitable for small to medium single-room applications.

Q3: Is this a complete air conditioner?
A: No, this is the indoor unit only. It must be paired with a compatible ActronAir outdoor unit to operate.

Q4: What type of airflow does it provide?
A: It delivers strong, ducted-style airflow with multiple fan speeds, typically around 130–180 L/s depending on mode, ensuring even room distribution.

Q5: Is it quiet during operation?
A: Yes, it is designed for low noise levels, operating as low as ~30–35 dBA, making it suitable for bedrooms and quiet spaces.

Q6: Does it include a drain system?
A: Yes, it comes with a built-in condensate drain pump, helping remove water efficiently even in ceiling installations.

Q7: What refrigerant system does it support?
A: It is compatible with modern ActronAir systems using R32 or R410A depending on matched outdoor unit series (system-dependent).Ā 


Maintenance Tips
  • Clean return air filter every 2–4 weeks (critical): Prevents airflow restriction and keeps steady 3.5 kW cooling and 3.8 kW heating performance.
  • Inspect indoor coil every 6–12 months: Dust buildup reduces efficiency, causes weak airflow, and can lead to musty odors in concealed bulkhead installs.
  • Check condensate drain & pump regularly: This model uses a built-in drain pump—ensure it’s clear to prevent ceiling leaks or water overflow.
  • Flush drain system annually: Removes sludge/algae buildup that commonly blocks bulkhead drainage lines.
  • Keep air return and discharge paths unobstructed: Bulkhead systems rely on ducted airflow balance—blocked returns reduce performance fast.
  • Verify electrical connections during service: Loose wiring can trigger faults or intermittent shutdowns in concealed ceiling installations.
  • Run seasonal test cycles: Check cooling and heating modes before peak summer/winter use to catch early issues.
  • Professional HVAC service yearly: Required for deep coil cleaning, airflow balancing, and system diagnostics in concealed units.
  • Avoid DIY internal cleaning: Only filters are user-serviceable—internal access requires trained technicians due to ceiling-mounted configuration.