Actron Air

ActronAir CRE-100AS / URC-100AS 10kW Cassette Split System - CRE-100AS / URC-100AS

ActronAir CRE-100AS / URC-100AS 10kW Cassette Split System - CRE-100AS / URC-100AS

review stars 1 Review

5% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $4,733.00 Sale price $4,496.99
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$30.00

$28.99

$70.00

$66.99

Add-Ons Bundle

$30.00

$28.99

$70.00

$66.99

Bundle Offer

$100.00

$95.98

Recently Viewed

ActronAir CRE-100AS / URC-100AS 10kW Cassette Split System - CRE-100AS / URC-100AS

The ActronAir CRE-100AS / URC-100AS 10kW Cassette Split System offers superior climate control with advanced technology and a sleek design. Equipped with a powerful 10kW cooling and 10.7kW heating capacity, this system efficiently maintains comfort in diverse environments. The unit features an inverter twin-rotary compressor, R410A refrigerant, and a premium wired controller for precise settings. Ideal for both residential and commercial spaces, it seamlessly integrates into any setting, ensuring consistent performance with minimal energy consumption.

Specifications
Technical Information
OUTDOOR MODEL URC-100AS
INDOOR MODEL CRE-100AS
Nett (Rated) Capacity (kW) (AS/NZS3823.1.1) Cooling (min max) 10.50 (4.20 - 12.60)
Heating (min max) 10.70 (4.32 - 12.95)
Input Power (kW) (AS/NZS3823.1.1) Cooling Rated 3.11
Heating Rated 2.88
EER Rated (AS/NZS3823.1.1) / COP Rated (AS/NZS3823.1.1) Cooling 3.38
Heating 3.72
Star Rating (AS/NZS3823.1.1) Cooling 2.0
Heating 2.5
Power Supply (V / Ph / Hz) Outdoor 220 240 V / 1Ph+N / 50Hz
Rated Load Amps (AS/NZS3823.1.1) Cooling 13.7
Heating 12.7
Full Load Amps (AS/NZS3823.1.1) 21.5
Circuit Breaker Amps 25.0
Suggested Minimum Mains Cable Size 4.0mm²
Suggested Minimum Indoor to Outdoor Power Cable Size & Type 1.0mm² 2 Core + Earth
IP Rating Outdoor IP24
Indoor IP20
Moisture Removal (L/hr) 1.7
Compressor Type Inverter Twin-Rotary
Refrigerant R410A
Airflow Range Indoor (l/s) High 444
Medium 408
Low 361
Outdoor Dimensions (mm) Depth 410
Height 810
Width 946
Indoor Dimensions (mm) Depth 840
Height 287
Width 840
Indoor Panel Dimensions (mm) Depth 950
Height 55
Width 950
Nominal Weight (kgs) Outdoor 69
Indoor 36
Indoor Sound Pressure Level (dBA) (Low / Med / High) 44 / 48 / 51
Outdoor Sound Pressure Level (dBA) 1m 62
Outdoor Sound Power Level (dBA) 70
Outdoor Operating Range (C) Cooling -15C to 50C
Heating -25C to 30C
MEPS Compliant Yes
Demand Response Capability (AS4755.3) Capable
What our Experts Think
  • High-capacity cassette comfort system: The ActronAir CRE-100AS / URC-100AS is a 10–10.5 kW reverse-cycle cassette split system, designed for large rooms, offices, and open-plan spaces, delivering strong all-season heating and cooling performance.
  • Powerful whole-space coverage: With around 10.5 kW cooling and 10.7 kW heating capacity, it’s built to maintain stable comfort in medium-to-large zones, even in demanding climates.
  • 360° air distribution advantage: The 4-way cassette airflow design spreads conditioned air evenly across the room, reducing hot/cold spots and improving overall comfort consistency.
  • Efficient inverter operation: Uses a twin-rotary inverter compressor, adjusting output dynamically to match demand, helping improve efficiency and reduce energy waste during partial loads.
  • Strong operating range: Performs reliably in extreme conditions, operating from -25°C heating to 50°C cooling, making it suitable for demanding environments.
  • Quiet, discreet indoor design: The cassette format is ceiling-mounted and low-profile, keeping interiors clean and uncluttered while maintaining effective airflow distribution.
  • Smart usability features: Includes auto fan speeds, adjustable louvers, self-diagnostics, and drain pump integration, improving installation flexibility and long-term maintenance ease.

Q&A

Q1: What is the cooling and heating capacity of this system?
A: It delivers approximately 10.5 kW cooling and 10.7 kW heating, suitable for medium to large residential rooms or light commercial spaces.

Q2: What type of air conditioner is it?
A: It is a 4-way cassette split system, with the indoor unit (CRE-100AS) mounted in the ceiling and the outdoor unit (URC-100AS) handling heat exchange.

Q3: How efficient is the system?
A: It uses an inverter twin-rotary compressor, offering efficient performance with COP around 3.7 (heating) and strong energy control for variable load conditions.

Q4: What size space is it suitable for?
A: Typically suited for large bedrooms, offices, shops, or open-plan areas around 40–65 m² (or larger depending on insulation and climate).

Q5: Does it support even air distribution?
A: Yes, it features 360° airflow with independent louvre control, ensuring even cooling or heating across the room.

Q6: Is it energy efficient for long-term use?
A: Yes, it includes MEPS compliance and inverter technology, helping reduce power consumption by adjusting output based on demand. 


Maintenance Tips
  • Clean air filters monthly (essential): Prevent airflow restriction, reduce energy use, and maintain strong 10.5 kW cooling / 10.7 kW heating performance.
  • Professional coil cleaning annually: Indoor cassette and outdoor condenser coils must be kept clean to preserve efficiency and avoid compressor strain.
  • Check condensate drain & pump: Ensure the built-in drain pump flows freely to prevent water leaks or ceiling overflow.
  • Inspect 4-way airflow system: Keep louvers and discharge vents clear for balanced 360° air distribution and consistent room comfort.
  • Outdoor unit clearance check: Remove dust, leaves, and debris around URC-100AS to maintain heat exchange efficiency and airflow.
  • Verify refrigerant performance (technician-only): Ensure R410A system pressure is stable—low charge reduces cooling/heating capacity.
  • Electrical connection inspection: Tighten terminals and check circuit breaker (typically 25A) for safe operation and reliability.
  • Seasonal system test: Run cooling and heating modes before peak seasons to catch early faults in sensors or compressors.
  • Use licensed HVAC servicing only: Internal work involves pressurized refrigerant and must be handled by qualified technicians.