Get In Touch
Get In Touch +1 (888) 575-2099
Dial +1 (888) 575-2099
grab it before it's gone.
As low as possible.
Never used.
$200.00
$70.00
$100.00
$30.00
$300.00
$100.00
Products added to cart!
The EcoTemp WCA4 Air Conditioner is a high-quality residential HVAC product designed to provide efficient cooling for your home. It features a reliable refrigeration circuit, which includes scroll compressors on all models and a durable copper tube / aluminum fin coil, providing long-lasting and efficient performance.
Installing and servicing the WCA4 Air Conditioner is simple, thanks to its easy access service valves and external high and low refrigerant service ports. Additionally, the control panel can be accessed with only two screws, making maintenance and repairs hassle-free.
The WCA4 Air Conditioner is factory charged with R-410A refrigerant, ensuring optimal performance and reducing the need for frequent maintenance. The unit is built to last, with a pre-painted cabinet finish over galvanized steel and a coated inlet grille with 3/8” (10mm) grille spacing for extra protection against wear and tear.
WCA4604GKA Air Conditioner Features:
Air Conditioner
14 Seer
R-410A Refrigerant
1-5 Tons
Split System
208/230 Volt
1-Phase
60 Hz
WAXL604A Fan Coil Features:
Fan Coils
1.5-5 TON
600-2000 CFM
Model | WCA4604GKA,WAXL604A |
---|---|
AHRI Number | 9548906 |
Bundle Avg Coverage Area | 2,500 - 3,000 Sq Ft |
Bundle Cooling Capacity | 5 Ton |
Bundle Cooling Efficiency | 14 SEER |
EER | 11.5 |
WCA4604GKA Specifications | |
Model | WCA4604GKA |
Avg Coverage Area | 2,500 - 3,000 Sq Ft |
Compressor | Single Stage |
Cooling Capacity | 5 Ton |
Electrical Phase | 1-Phase |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 40 amps |
Product Height (in) | 31.1875 |
Product Length (in) | 31.1875 |
Product Width (in) | 31.1875 |
Refrigerant | R-410a |
Cooling Efficiency | 14 SEER |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts, 1 Year Unit Replacement |
Weight (lbs) | 218.0000 |
WAXL604A Specifications | |
Model | WAXL604A |
Air Flow Direction | Downflow, Horizontal, Upflow |
Configuration | Floor Mounted |
Blower Motor | Variable Speed |
Cooling Capacity | 5 Ton |
Electrical Phase | 1-Phase |
Heat Strip Compatibility | Up to 20 kW |
Line Set Connection Type | Sweat |
Liquid Line Size | 3/8 inch |
Max Overcurrent Protection | 15 amps |
Product Height (in) | 59.1875 |
Product Length (in) | 22.0625 |
Product Width (in) | 24.6875 |
Suction Line Size | 7/8 inch |
System Application Type | Central Split Systems |
Voltage | 240 |
Warranty | 10 Year Parts |
Weight (lbs) | 201.0000 |
WCA4604GKA Air Conditioner
Refrigeration Circuit
Scroll compressors on all models
Copper tube / aluminum fin coil
Easy to Install and Service
Easy Access service valves on all models
External high and low refrigerant service ports
Only two screws to access control panel
Factory charged with R−410A refrigerant
Built to Last
Pre−painted cabinet finish over galvanized steel
Coated inlet grille with 3/8” (10mm) grille spacing for extra protection
WAXL604A Fan Coil
1−1/2 Thru 5 Tons
Environmentally Sound R−410a Systems
Multiposition Installation − Upflow Or Horizontal Left Standard.
Horizontal Right With Minor Modification.
Field Convertible To Downflow With Available Accessory Kit.
Txv Metering Device Factory Installed
Sweat Connections
Primary And Secondary Drain Fittings With Brass Inserts
3 Amp Automotive Type Fuse In Wire Harness
Multiple Electrical Entry Locations
Time Delay Relay (TDR) Programmed In Motor
Field Installed Heater Packages From 5 Kw − 30 Kw Available Separately
Hud Approved For Manufactured Housing
208/230−1−60 Supply Voltage
Units Tested And Certified By Manufacturer To Achieve A 2% Or Less Leakage Rate At 1.0 Inch Water Column
1 Inch (25mm) Thick Insulation With R Value Of 4.2
Ecm Motor
No Heat (Plug) Kit Factory Installed
Filter (Washable) Factory Supplied
✓EcoTemp WCA4 Installation Manual
✓EcoTemp WCA4 Specification Manual
Q: What is the EcoTemp WCA4604GKA 5 Ton Central Air Conditioner used for?
A: The EcoTemp WCA4604GKA is a 5-ton, 14.5 SEER variable-speed central air conditioner split system, designed to provide efficient and reliable cooling for larger residential or commercial spaces.
Q: What is SEER, and how does the 14.5 SEER rating benefit me?
A: SEER stands for Seasonal Energy Efficiency Ratio. The 14.5 SEER rating ensures that this system delivers effective cooling while minimizing energy consumption and reducing your overall electricity costs.
Q: How does the variable-speed technology enhance performance?
A: The variable-speed blower motor adjusts airflow based on cooling demands, offering quieter operation, improved humidity control, and increased energy efficiency throughout the cooling process.
Q: Can the EcoTemp WCA4604GKA be installed in various positions?
A: Yes, this system is multiposition, allowing for flexible installation in horizontal, vertical, or upflow configurations, depending on your space requirements.
Q: Why should I choose the EcoTemp WCA4604GKA air conditioner?
A: With its 14.5 SEER energy efficiency, variable-speed motor for optimal comfort, and versatile multiposition installation options, the EcoTemp WCA4604GKA is the perfect solution for efficiently cooling larger spaces with consistent, quiet performance.
Replace or Clean Air Filters Regularly: Check and clean or replace the air filters every 1-3 months. Clogged filters reduce airflow, decrease efficiency, and strain the system. Keeping filters clean helps maintain optimal airflow and indoor air quality.
Clean the Coils Annually: Clean both the evaporator and condenser coils once a year to remove dirt, dust, and debris. Dirty coils affect heat exchange, leading to lower efficiency and higher energy bills. Use a soft brush and coil cleaner to gently remove buildup.
Check Refrigerant Levels: Have a licensed technician inspect the refrigerant levels annually. Low refrigerant levels can impair cooling performance and cause compressor damage. The technician will also check for leaks and re-charge the system if necessary.
Clear Outdoor Unit of Debris: Ensure the outdoor unit is free from debris such as leaves, dirt, and branches. Keep a 2-foot clearance around the unit to allow for proper airflow. Blocked airflow can cause the system to overheat and work harder, reducing efficiency.
Inspect the Condensate Drain: Periodically check the condensate drain to ensure it’s not clogged. A blocked drain can lead to water damage and mold growth. Use a wet/dry vacuum or pipe cleaner to clear any obstructions and maintain proper drainage.
Check for Ductwork Leaks: Inspect ductwork for leaks or damage. Leaky ducts can lead to inefficient cooling and higher energy consumption. Seal any visible leaks and ensure ducts are clear of any blockages to maintain proper airflow.
Test Thermostat Functionality: Verify that the thermostat is correctly calibrated and is maintaining the desired temperature. Consider using a programmable or smart thermostat to optimize energy savings by adjusting temperatures when you’re away from home or asleep.
Inspect Insulation: Ensure the insulation around refrigerant lines and ducts is intact. Damaged or deteriorated insulation can cause energy loss, forcing the system to work harder. Replace any worn-out insulation to keep energy efficiency high.
Ensure Unobstructed Airflow: Check that all air vents and registers are open and not blocked by furniture, rugs, or other objects. Proper airflow is essential for system efficiency and uniform cooling throughout your home.
Schedule Annual Professional Maintenance: Arrange for a professional maintenance check every year. A technician will clean the coils, check refrigerant levels, inspect the variable-speed blower, and ensure the system is running at optimal performance.
Thanks for subscribing!