Skip to product information
1 of 10

Goodman

Goodman - 2 Ton/24,000 BTU - Multi-Positional - Air Conditioner Split System - 14 SEER2 - R32 - GLXS3BN2410

Goodman - 2 Ton/24,000 BTU - Multi-Positional - Air Conditioner Split System - 14 SEER2 - R32 - GLXS3BN2410

review stars 1 Review

3% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $3,327.70 Sale price $3,237.00
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Goodman - 2 Ton/24,000 BTU - Multi-Positional - Air Conditioner Split System - 14 SEER2 - R32 - GLXS3BN2410 

A Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman air conditioner split system is the perfect choice for all of your cooling needs.

Features
  • Ideal size to cover a medium-sized house
  • 2 ton, 13.4 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Low sound output
  • Fully charged for up to 15' of line set
  • Factory-installed filter drier
  • Air Handler
  • 2 ton air handler
  • Electric heat compatible
  • Optimized for use with R-32 refrigerant
  • Multi-speed, direct drive ECM blower motor
  • Multi-positional (upflow, downflow, or horizontal)
Specifications
2 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32
SKU GLXS3BN2410
Weight 130.000000
Manufacturer Goodman
Replaces Add GSX130241 and GSXN3N2410
Cooling BTU 24,000
Blower Motor Single Speed PSC Motor
Decibel Level (dBA) 74
Horsepower 1/8 HP
Refrigerant R32
SEER2 13.4
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208 / 230 V. 1 Phase 60 Hz
Max Breaker Size 15 Amps
Min. Breaker Size 10.9 Amps
Tonnage 2 Ton
Connection Sweat
Height 27.5"
Width 26"
Depth 26"
Manual
What our Experts Think
  • All‑Season Comfort Package – A matched HVAC system pairing a 1.5 ton air conditioner with a 60,000 BTU, 80% AFUE gas furnace that delivers reliable cooling in summer and dependable heat in winter.

  • 14.5 SEER2 Cooling Efficiency – Meets modern DOE efficiency standards for cost‑effective summer cooling and lower electricity usage than older systems.

  • 80% AFUE Gas Furnace – Converts a high percentage of fuel into heat, offering steady home heating at a strong value point.

  • Horizontal Configuration – Engineered for attic or crawl‑space installations with horizontal ductwork, maximizing installation flexibility.

  • R‑32 Refrigerant Ready – Designed for next‑generation R‑32 refrigerant, aligning with current environmental and regulatory standards.

  • Factory‑Matched Evaporator Coil with TXV – Helps ensure precise refrigerant metering and smooth performance across seasons.

  • Durable Construction & Warranty Support – Quality coil and system components backed by Goodman’s limited warranty when registered, increasing long‑term reliability.

  • Balanced Performance & Value – A well‑rounded package that provides efficient cooling and reliable heating at a competitive price point, ideal for small to medium homes.


Q&A

Q: What components are included in this Goodman HVAC package?
A: A complete matched system with a **1.5 ton R32 air conditioner condenser (≈18,000 BTU cooling), a horizontal evaporator coil (CHPTA1822B3) with factory‑installed TXV, and a 96% AFUE 80,000 BTU gas furnace for efficient year‑round comfort.

Q: What size space is this system designed for?
A: This system is typically ideal for small to medium homes (≈700–1,000 sq ft) depending on insulation, layout, and local climate.

Q: What does 14.5 SEER2 mean?
A: 14.5 SEER2 is the cooling efficiency rating — it reflects efficient seasonal cooling performance that helps reduce electricity use and cost compared with older, lower‑SEER units.

Q: What does 96% AFUE mean?
A: 96% AFUE means 96% of the furnace fuel is converted into usable heat, delivering high‑efficiency heating with lower natural gas costs.

Q: What are the key features of the included evaporator coil (CHPTA1822B3)?
A: The horizontal coil is optimized for R32 refrigerant, has an all‑aluminum design, and a factory‑installed TXV, which improves cooling efficiency and system responsiveness.

Q: What refrigerant does the system use?
A: This system uses R32 refrigerant, a modern, more efficient refrigerant with lower environmental impact.

Q: What installation orientation does it support?
A: It’s designed for horizontal left‑or‑right installation, suitable for attics, closets, or compact mechanical spaces.


Maintenance Tips
  • Replace Air Filters Every 1–3 Months: Maintains airflow, protects furnace and AC components, and ensures efficient operation.

  • Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.

  • Clean Outdoor AC Condenser: Rinse coils every 3–6 months to maintain SEER2 performance and prevent debris buildup.

  • Annual Professional Inspection: Have a certified technician check burners, heat exchanger, gas pressure, and airflow for safe and efficient furnace operation.

  • Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 efficiency.

  • Maintain Condensate Drains: Keep furnace and AC drain lines clear to prevent water issues or system shutdowns.

  • Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.

  • Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling require prompt professional attention.