Main Specification:
- Continuous Output Power:18.0KW
- Surge Rating(20s) :54.0KW
- Output Waveform:Pure Sine Wave
- AC Output Voltage: 120V and 240V
- AC Input Voltage:240V( not suitable for AC 120V input )
- DC Battery Voltage:48Vdc
- Solar charger Current:40Amp
- AC Battery charger:100±5Amp
- Output Frequency:50Hz /60Hz
- Typical transfer Time:10ms(Max)
DC Input:
- Nominal Input Voltage:48.0Vdc
- Minimum Start Voltage:40.0Vdc / 42.0Vdc
- Low Battery Alarm:42.0Vdc / 44.0Vdc
- Low Battery Trip:40.0Vdc / 42.0Vdc
- High Voltage Alarm:64.0Vdc
- Low Battery voltage recovery:62.0Vdc
- Power Saver on Idle Consumption: 50W
- Power Saver off Idle Power: 270W
Charger :
- Output Voltage: Depends on battery type
- Battery Initial Voltage for Start-Up: 40-62.8V
- Over Charge Protection Shutdown:62.8V
- Charger Breaker: 100A
- Input Voltage Waveform: Pure Sine wave (Grid or Generator)
- AC input range:184-253Vac/140-270Vac
- Nominal Input Frequency :50Hz or 60Hz (Auto detect)
Solar Charger controller:(you can disable our solar controller, and connect with an external solar controller)
- Solar Input Voltage Range: 60-100Vdc
- Max.PV Open Circuit Array Voltage:105Vdc
- Rated Charge Current: 40A
- Over Charge Disconnection: 59.2V
- Over Charge Recovery: 54.4V
- Over Discharge Disconnection: 43.2 V(default)
- Over Discharge Reconnection: 49.2V