Fujitsu 12.5kW Multi Head Outdoor Unit Only - AOTG45LBLA6

by FUJITSU
SKU AOTG45LBLA6
Save 6% Save 6%
Original price $4,357.00
Original price $4,357.00 - Original price $4,357.00
Original price $4,357.00
Current price $4,095.99
$4,095.99 - $4,095.99
Current price $4,095.99
  • CLEARANCE SALE.

  • ITEMS LEFT.

  • PEOPLE are also watching that product.


Fujitsu 12.5kW Multi Head Outdoor Unit Only  - AOTG45LBLA6

The Fujitsu AOTG45LBLA6 Reverse Cycle Outdoor Unit stands out as a robust choice for environments needing powerful and efficient climate control. With a substantial cooling capacity of 12.5 kW and heating capacity of 13.5 kW, it ensures effective temperature management even in larger spaces or buildings. This makes it particularly suitable for commercial applications where maintaining a comfortable indoor environment is crucial year-round.

In terms of efficiency, the unit boasts impressive Energy Efficiency Ratios (EER) and Coefficients of Performance (COP), with an EER of 3.5 for cooling and COP of 4 for heating. These metrics signify its ability to deliver cooling and heating while minimizing energy consumption, which is essential for reducing operational costs and environmental impact. Additionally, its high Seasonal Performance Factors (SPF) further enhance its efficiency across varying weather conditions, ensuring reliable performance in both residential and commercial settings.

  • Capacity: It provides a cooling capacity of 12.5 kW and a heating capacity of 13.5 kW, ensuring efficient temperature regulation throughout the year.

  • Power Efficiency: The unit has an Energy Efficiency Ratio (EER) of 3.5 for cooling and a Coefficient of Performance (COP) of 4 for heating, contributing to energy savings.

  • Seasonal Performance: It achieves high Seasonal Performance Factors (SPF), with residential ratings of 5.374 (cooling) and 5.19 (heating) in hot conditions, ensuring effective performance across different environmental conditions.

  • Sound Levels: Outdoor sound levels are kept relatively low with sound pressures of 52 dBA (cooling) and 54 dBA (heating), minimizing operational noise disturbances.

  • Dimensions and Weight: The unit measures 998 mm (height) x 970 mm (width) x 370 mm (depth) and weighs 94.00 kg, designed for durability and ease of installation.

Operation Type Reverse Cycle
Maximum Connectable Indoor Units 6
Power Source V/Ph/Hz 240 / 1 / 50
Capacity Class kW 12.5
Cooling Capacity kW (Rated (Min – Max)) 12.50 (3.5 – 14)
Heating Capacity kW (Rated (Min – Max)) 13.50 (3.5 – 16)
Input Power Cooling kW (Rated (Max)) 3.57 (5.02)
Input Power Heating kW (Rated (Max)) 3.37 (4.59)
EER Cooling kW/kW 3.5
COP Heating kW/kW 4
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.374 / 4.937 / 5.215
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.19 / 4.595 / 4.125
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.847 / 6.052 / 6.556
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.203 / 4.847 / 4.425
Outdoor Sound Pressure dBA (Cooling / Heating) 52 / 54
Outdoor Sound Power dBA 68
Outdoor Unit Dimensions mm (Height x Width x Depth) 998 x 970 x 370
Outdoor Unit Weight kg 94.00
Pipe Length m (Max (Pre charged)) 80 (50)
Operation Range Cooling °CDB (Min to Max) -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 4,000

 

 

 

Fujitsu 12.5kW Multi Head Outdoor Unit Only  - AOTG45LBLA6

The Fujitsu AOTG45LBLA6 Reverse Cycle Outdoor Unit stands out as a robust choice for environments needing powerful and efficient climate control. With a substantial cooling capacity of 12.5 kW and heating capacity of 13.5 kW, it ensures effective temperature management even in larger spaces or buildings. This makes it particularly suitable for commercial applications where maintaining a comfortable indoor environment is crucial year-round.

In terms of efficiency, the unit boasts impressive Energy Efficiency Ratios (EER) and Coefficients of Performance (COP), with an EER of 3.5 for cooling and COP of 4 for heating. These metrics signify its ability to deliver cooling and heating while minimizing energy consumption, which is essential for reducing operational costs and environmental impact. Additionally, its high Seasonal Performance Factors (SPF) further enhance its efficiency across varying weather conditions, ensuring reliable performance in both residential and commercial settings.

  • Capacity: It provides a cooling capacity of 12.5 kW and a heating capacity of 13.5 kW, ensuring efficient temperature regulation throughout the year.

  • Power Efficiency: The unit has an Energy Efficiency Ratio (EER) of 3.5 for cooling and a Coefficient of Performance (COP) of 4 for heating, contributing to energy savings.

  • Seasonal Performance: It achieves high Seasonal Performance Factors (SPF), with residential ratings of 5.374 (cooling) and 5.19 (heating) in hot conditions, ensuring effective performance across different environmental conditions.

  • Sound Levels: Outdoor sound levels are kept relatively low with sound pressures of 52 dBA (cooling) and 54 dBA (heating), minimizing operational noise disturbances.

  • Dimensions and Weight: The unit measures 998 mm (height) x 970 mm (width) x 370 mm (depth) and weighs 94.00 kg, designed for durability and ease of installation.

Operation Type Reverse Cycle
Maximum Connectable Indoor Units 6
Power Source V/Ph/Hz 240 / 1 / 50
Capacity Class kW 12.5
Cooling Capacity kW (Rated (Min – Max)) 12.50 (3.5 – 14)
Heating Capacity kW (Rated (Min – Max)) 13.50 (3.5 – 16)
Input Power Cooling kW (Rated (Max)) 3.57 (5.02)
Input Power Heating kW (Rated (Max)) 3.37 (4.59)
EER Cooling kW/kW 3.5
COP Heating kW/kW 4
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.374 / 4.937 / 5.215
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.19 / 4.595 / 4.125
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.847 / 6.052 / 6.556
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.203 / 4.847 / 4.425
Outdoor Sound Pressure dBA (Cooling / Heating) 52 / 54
Outdoor Sound Power dBA 68
Outdoor Unit Dimensions mm (Height x Width x Depth) 998 x 970 x 370
Outdoor Unit Weight kg 94.00
Pipe Length m (Max (Pre charged)) 80 (50)
Operation Range Cooling °CDB (Min to Max) -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 4,000