Quatro Desktop Plating Fume Hood-Small Containment Cabinet - RH-DTA1

Quatro Desktop Plating Fume Hood-Small Containment Cabinet - RH-DTA1

FREE SHIPPING
CLEARANCE SALE
80 Peoples are also watching.
Brand: Quatro
SKU: RH-DTA1
$1,217.99
$1,295.00
$1,217.99
Subtotal: $1,217.99
clearance sale ends in
00 Hours
00 Minutes
00 Seconds
authorized dealer, shop your favorite brand.
Expert Support,

Dial +1 (888) 575-2099

Limited Supply,

grab it before it's gone.

Lowest prices,

As low as possible.

All Items are brand New,

Never used.

Quatro Desktop Plating Fume Hood-Small Containment Cabinet - RH-DTA1

Quatro Desktop Plating Fume Hood-Small Containment Cabinet - RH-DTA1

$1,295.00 $1,217.99

Quatro Desktop Plating Fume Hood-Small Containment Cabinet - RH-DTA1

$1,295.00 $1,217.99

Recently Viewed Products

Quatro Desktop Plating Fume Hood-Small Containment Cabinet - RH-DTA1 

This stand alone Quatro unit absorbs fumes from jewelry plating of Rhodium, Gold and other metals. The Quatro Desktop Plating Fume Hood keeps fumes out of the workplace by using activated charcoal filters to scrub the dangerous fumes out of the air you and your employees breath. The Quatro Desktop Plating Fume Hood has a quiet variable speed motor so you can turn it up when solutions are being heated and fumes are being produced. The unit will also indicate when it's time to replace on of the three filters-Top filter for Rhodium or Gold odor, middle HEPA filter, and bottom dust filter, so you can keep operating at peak performance.  Includes LED light inside containment cabinet. This unit is 120V/60hz.

The Quatro Desktop Plating Fume Hood overall measurements are 29" Height by 24" Width by 17" Depth.  Containment Cabinet measures 14-1/2" Height x 24" Width x 17" Depth.   Sound level 50-55 dB(A). This product ships in 2 boxes, with a total shipping weight of 90 lbs.

The Quatro Desktop Plating Fume Hood Rh-DTA-1 has 4 stages of filters:

  • Stage 1 F071 Dust Filter (Otto Frei 147.628A)

  • Stage 2 F074-Hepa Filter (Otto Frei 147.610D)

  • Stage 3 F072-BPC Rhodium-Plating Fume Filter (Otto Frei 147.629C)

  • Stage 3 Charcoal Refill NC-BPC (Otto Frei 147.629D)

  • Stage 4 F069-220-Dust Pads(Otto Frei 147.628E)

  • Compact & Efficient: The Quatro Desktop Plating Fume Hood (RH-DTA1) is a compact, efficient solution for small-scale plating operations, offering effective fume extraction and containment in a limited workspace.
  • Effective Fume Containment: Designed to capture and filter hazardous fumes generated during plating processes, this fume hood ensures a safer working environment by preventing harmful chemicals from escaping into the air.
  • User-Friendly: Featuring an easy-to-use control panel, the RH-DTA1 allows for simple operation and effective airflow control, making it ideal for professionals needing a portable yet efficient fume extraction solution.
  • Durable Construction: Built with high-quality materials, this fume hood is designed to withstand the demands of the plating process, offering long-lasting performance in both industrial and lab settings.
  • Space-Saving Design: Its small footprint makes it suitable for desktop use or tight spaces, providing powerful fume extraction without occupying large areas of the workspace.
  • Enhanced Safety: Equipped with reliable filtration systems, the RH-DTA1 provides an additional layer of safety by removing toxic fumes and particles from the air, ensuring a cleaner, healthier working environment.

Q: What is the Quatro Desktop Plating Fume Hood - Small Containment Cabinet?
A: The Quatro Desktop Plating Fume Hood (RH-DTA1) is a compact fume extraction system designed for small-scale plating and chemical processes. It provides a controlled environment to capture hazardous fumes and vapors, ensuring a safe workspace.

Q: What are the features of the RH-DTA1?
A: The RH-DTA1 features a small, space-efficient design with a powerful exhaust fan, an integrated filtration system, and a durable containment cabinet. It is equipped with a HEPA filter to capture particulate matter and an activated carbon filter to eliminate fumes and odors.

Q: Is the Quatro Desktop Plating Fume Hood suitable for commercial use?
A: Yes, the RH-DTA1 is ideal for small commercial operations, laboratories, or workshops where plating or chemical processes are performed, ensuring that harmful fumes are safely contained and filtered.

Q: How does the Quatro Desktop Plating Fume Hood work?
A: The fume hood works by drawing in toxic fumes and vapors produced during plating processes, passing them through the filtration system, and releasing purified air. The system captures harmful particles and gases to maintain air quality and safety.

Q: Does the Quatro Desktop Plating Fume Hood come with accessories?
A: Yes, the RH-DTA1 typically includes the fume hood unit, pre-installed filters, and essential components. Replacement filters and additional accessories may be available to ensure optimal performance.

  • Clean the Hood After Each Use: Wipe down the interior and exterior surfaces of the fume hood after each use to remove any chemicals, dust, or fumes. Use a mild, non-abrasive cleaner to avoid damaging the surface.
  • Check and Replace Filters Regularly: Inspect the air filters for signs of clogging or wear. Replace the filters at the recommended intervals or sooner if airflow is reduced or the filter appears saturated with contaminants.
  • Inspect the Exhaust System: Regularly inspect the exhaust fan and ducting for dust or residue buildup that could obstruct airflow. Clean the fan blades and ducts as needed to ensure efficient exhaust.
  • Monitor Airflow: Test the airflow to ensure the fume hood is ventilating properly. A drop in airflow may indicate a clog in the filter, fan, or ducts. Address any issues promptly to maintain safe operation.
  • Check the Electrical Components: Ensure the power supply and electrical components are functioning properly. Inspect wiring and switches for damage, and replace any defective parts to avoid safety hazards.
  • Lubricate Moving Parts: If applicable, lubricate any moving parts, such as the fan motor or door mechanisms, with a food-safe or recommended lubricant to prevent friction and extend the life of the system.
  • Inspect the Containment Cabinet: Check the containment cabinet for any signs of wear, cracks, or damage. Ensure that the cabinet seals tightly to prevent fume leakage. Replace seals or any damaged components as necessary.
  • Maintain the Work Surface: Clean and maintain the work surface inside the cabinet, ensuring it is free from corrosive substances. Check for any damage or wear to the surface, and replace it if needed.
  • Verify Safety Features: Ensure that safety features, such as alarms or airflow indicators, are working correctly. Test these safety mechanisms regularly to ensure they are operational.
  • Store Properly: When not in use, ensure the fume hood is stored in a clean, dry, and well-ventilated area. This will help prevent any buildup of dust or contaminants that could affect performance.

Related Products

Brand: Brand
Example product title
$1,217.99
$1,295.00
$1,217.99
Brand: Brand
Example product title
$1,217.99
$1,295.00
$1,217.99
Brand: Brand
Example product title
$1,217.99
$1,295.00
$1,217.99
Brand: Brand
Example product title
$1,217.99
$1,295.00
$1,217.99