The DS200CTBAG1A is an Analog Termination Board (CTBA) designed for use within the SPEEDTRONIC Mark V LM Turbine Control systems. This printed circuit board plays a crucial role in managing and controlling wind, steam, and gas turbine automated drive assemblies, utilizing General Electric's patented Speedtronic technology. As part of the Mark V Turbine Control System Series, the DS200CTBAG1A serves as a legacy component despite being part of the more recent offerings, due to its eventual discontinuation by the manufacturer.
The DS200CTBAG1A Analog Termination Module is integral to the SPEEDTRONIC Mark V LM Turbine Control systems, focusing on managing wind, steam, and gas turbine automated drive assemblies. This module, detailed in the Functional Manual GEH-6153, belongs to the final iterations of General Electric's Mark product series employing Speedtronic control technology.
Positioned within the Mark V Turbine Control System Series, the DS200CTBAG1A serves as a Termination Module, specifically designed for the system's common data processor located within the C core. It facilitates crucial terminal signals including Ma. Input, Ma. Output, and communication links to IONET and ARCNET processors. A notable feature is the RS-232 9-pin d-shell serial port, enabling TIMN diagnostics.
GE FANUC, now part of Emerson Automation Solutions, was a leading provider of industrial automation and control systems. Known for innovative solutions, GE FANUC played a key role in advancing manufacturing, offering a range of products including PLCs, CNCs, and HMI solutions.
Part Number |
DS200CTBAG1A |
---|---|
Manufacturer |
General Electric |
Function |
Termination Board |
Series |
Mark V LM |
Operating Temperature |
-28 to 55°C |
Board Size |
6.25 in x 4.25 in |
Category |
PLCs/Machine Control |
Subcategory |
PC Board PLC/Add-On Board |
Weight |
1.00 lbs |
Precision Signal Handling: Provides accurate analog signal termination and conditioning for optimal system performance.
Improved System Integration: Ensures seamless connection between various components in GE FANUC control systems.
Robust Construction: Designed for reliable performance in demanding industrial environments.
Enhanced Signal Integrity: Reduces noise and interference, improving overall system stability.
Easy Installation: Plug-and-play functionality ensures quick integration and minimal downtime.
GE FANUC Quality: Trusted for durability, reliability, and long-term operational efficiency.
Q: What is the DS200CTBAG1A Analog Termination Module?
A: It’s a GE Fanuc module used for the termination of analog signals in industrial control systems, ensuring proper signal connection and transmission.
Q: What systems is it compatible with?
A: This module is designed for use with GE Fanuc Mark VI and other related control systems, typically in turbine and automation applications.
Q: What does the analog termination module do?
A: It connects analog input or output devices to the control system, providing necessary termination and ensuring accurate data transmission.
Q: Why choose the DS200CTBAG1A?
A: It ensures reliable signal integrity, smooth communication, and efficient operation in critical industrial systems, especially in power and turbine control.
Q: Is this an OEM product?
A: Yes, it’s a genuine GE Fanuc part, ensuring compatibility, high performance, and long-term durability in industrial environments.
Visual Inspection: Regularly inspect for signs of physical damage such as burnt components, corrosion on connectors, or damaged solder joints, particularly around analog signal paths.
Clean the Module: Use dry compressed air or an anti-static brush to gently clean dust and debris from the module. Avoid using liquids or solvents that can cause short circuits.
Check Analog Signal Integrity: Periodically verify the input and output analog signals to ensure they are within expected ranges and free from noise or interference.
Inspect Terminals and Connections: Examine all input/output terminals for corrosion, loose connections, or wear. Tighten and clean connections as necessary to ensure good signal flow.
Verify Power Supply: Ensure the module is receiving stable power within its specified range to avoid issues with signal transmission and module malfunction.
Monitor Operating Temperature: Ensure that the module operates within its specified temperature range. Overheating could affect the performance and accuracy of the analog signals.
Run Diagnostics: Use system diagnostics tools to regularly check the module’s performance, signal consistency, and any fault indicators.
ESD Precautions: Always handle the module using electrostatic discharge (ESD) protection, such as an anti-static wrist strap, to avoid damaging sensitive components.
Secure Installation: Ensure the module is securely mounted and not exposed to physical stress or vibrations, which could cause signal disruptions or component damage.