Modine Commercial Workspace Heater - 175K BTU/Direct Spark Ignition/NG/Separated Combustion/Single Stage w/Stainless Steel Heat Exchanger
Features
- Specifically designed for environments with hostile atmospheric conditions, such as chemicals, high humidity or negative pressure
- Combustion air is brought in from outside the heated area - either from outdoor air or from an adjacent room - eliminating the need to use contaminated indoor air for combustion
- In-shot burners fire each heat exchanger tube for reliable performance, ease of service and decreased noise on ignition
- Same-size vent and combustion air inlets throughout product line makes installation easier
- Longer allowable vent lengths (up to 50′ vs 30′) versus previous line, providing greater installation options
- Round vent pipe and combustion air inlet pipe connection
- Automatic reset vent pressure switch is designed to prevent operation of the main burner in the event there is restricted venting of the flue
- Integrated direct spark control board provides digital control of the air mover, inducer, ignition, gas valve and flame sense
- Control Step Down Transformer used to step down from 115v to 24v for the gas controls, fan delay relay, field supplied motor start and more
- Remote flame sensor verifies ignition of all burners, monitors the flame single and communicates with the integrated circuit board
- High limit control switch is mounted in the air stream and will shut off the gas supply in the event of overheating
- 4" vent & combustion air connection
- Natural Gas
- 150,000 BTU
- Direct spark ignition
- Single stage - on/off operation
- Aluminized steel heat exchanger
Specifications
Fuel Type |
Propane |
Control Type |
Electronic/IPI |
Color/Finish |
Gray |
Size |
42.53"W x 25.81"T x 32.83"D |
What Our Experts Think
-
175,000 BTU Heating Capacity: Provides robust heating for medium to large commercial spaces, ensuring warmth across expansive areas.
-
Natural Gas (NG) Fuel: A cost-effective and energy-efficient fuel option, ideal for businesses with natural gas infrastructure.
-
Separated Combustion: Draws combustion air from outside, keeping indoor air cleaner by reducing contaminants and enhancing air quality.
-
Direct Spark Ignition: Reliable, energy-efficient ignition system that eliminates the need for a pilot light, enhancing safety and lowering maintenance costs.
-
Single-Stage Operation: Simple, consistent heating ideal for maintaining steady temperatures in large workspace environments.
-
Stainless Steel Heat Exchanger: Offers superior durability and resistance to corrosion, ensuring long-lasting performance and effective heat transfer.
Q&A
Q: What is the Modine Commercial Workspace Heater?
A: The Modine Commercial Workspace Heater is a 175,000 BTU natural gas heater designed for large commercial and industrial spaces. It features direct spark ignition, separated combustion, single-stage operation, and a durable stainless steel heat exchanger.
Q: What size area can the Modine Commercial Workspace Heater heat?
A: This heater is ideal for spaces up to 4,375 square feet, providing efficient and reliable heating for expansive commercial environments.
Q: How does separated combustion improve performance?
A: Separated combustion ensures the heater draws air from outside, increasing safety and efficiency, especially in spaces with poor ventilation.
Q: Is this heater durable?
A: Yes, the stainless steel heat exchanger is built for durability and long-term reliability, even in harsh commercial environments.
Q: Can I install this heater in my commercial workspace?
A: Yes, it’s designed for ceiling-mounted installation in commercial spaces, providing optimal heating without taking up valuable floor space.
Maintenance Tips
-
Inspect Gas Lines & Connections – Check all gas lines and connections for leaks or damage. Tighten or replace fittings as necessary to ensure a safe operation.
-
Clean the Stainless Steel Heat Exchanger – Over time, dust and debris can accumulate in the heat exchanger, reducing efficiency. Regular cleaning helps maintain performance.
-
Examine Burner & Ignition System – Ensure the direct spark ignition system is working properly. If the heater fails to ignite or the flame is weak, clean or replace the components.
-
Ventilation & Intake Maintenance – Check the separated combustion system’s intake and vent to ensure no blockages. Adequate airflow is essential for efficient combustion.
-
Verify Safety Controls – Test the high-temperature limit switch and pressure switch to ensure the safety mechanisms are functioning correctly.
-
Thermostat Calibration – Make sure the thermostat is accurately reading and regulating the temperature. If it’s off, recalibrate or replace as needed.
-
Replace Filters – If the unit has filters, replace or clean them regularly to keep airflow optimal and reduce strain on the system.
-
Annual Professional Service – Schedule yearly maintenance by a qualified technician to ensure the heater is running efficiently and safely.