Only a few left—secure yours before it’s gone for good!
Your items are reserved, but only for a limited time!
Grab it now at a discounted price before the deal ends!
The Nidec-Embraco Compressor Model NT2210UV2 is designed for efficient refrigeration across residential and light commercial settings. This durable compressor is engineered to work with R290 refrigerant, providing an eco-friendly and powerful solution for refrigerators, freezers, and cold rooms.
Product Highlights
This model boasts robust construction and a lightweight design for easy installation and maintenance. Its superior efficiency not only meets but exceeds everyday cooling demands, contributing to lower operational costs and energy consumption.
Brand | Nidec-Embraco |
---|---|
Model Number (MPN) | NT2210UV2 |
Power Requirement | 208-230V, 1 Phase |
Refrigerant Type | R290 |
Horsepower (HP) | 1 1/4 HP |
High Efficiency: Delivers 1 1/4 HP for efficient cooling performance, ideal for medium-sized refrigeration applications that require reliable, consistent operation.
Eco-Friendly Refrigerant: Uses R290 (propane) as the refrigerant, offering an environmentally friendly alternative to traditional refrigerants, with lower global warming potential.
Versatile Power Supply: Operates on 208-230V, 1-phase power, making it suitable for a wide range of commercial refrigeration setups and easy to integrate into most systems.
Durable Design: Engineered by Nidec-Embraco, known for its durable and reliable compressors that are designed to withstand demanding conditions and long-term use.
Quiet Operation: Features noise-reduction technologies for quieter operation, ensuring minimal disruption in commercial settings like restaurants and convenience stores.
Versatile Applications: Perfect for use in commercial refrigerators, freezers, or beverage dispensers that require efficient, eco-friendly, and durable refrigeration.
Q: What is the Nidec-Embraco NT2210UV2 used for?
A: The NT2210UV2 is a hermetic refrigeration compressor designed for use in commercial refrigeration applications, such as reach-in coolers, freezers, and display cases.
Q: What is the power and voltage rating of the NT2210UV2 compressor?
A: It provides 1 1/4 HP and operates on 208-230V, single-phase electrical systems, making it compatible with most standard commercial refrigeration setups.
Q: What type of refrigerant does the NT2210UV2 support?
A: The NT2210UV2 is designed to use R290 refrigerant, a natural and environmentally friendly refrigerant option for commercial refrigeration systems.
Q: What are the key features of the Nidec-Embraco NT2210UV2?
A: Features include high efficiency, durability, quiet operation, and reliable performance in demanding refrigeration environments.
Q: Where is the NT2210UV2 compressor best suited?
A: It is ideal for use in commercial and industrial refrigeration systems that require a reliable, efficient compressor with a natural refrigerant for environmental compliance.
Keep the Compressor Clean:
Periodically clean the compressor and surrounding areas to prevent dirt and debris from entering. Ensure that air vents and cooling fins are clear for proper ventilation.
Check Electrical Connections:
Inspect all electrical terminals for tightness and signs of corrosion. Loose or corroded connections can lead to power loss, overheating, or compressor failure.
Monitor Refrigerant Levels:
Ensure that the refrigerant charge is within the manufacturer’s recommended range. Low refrigerant levels can lead to inefficient cooling and overworking of the compressor.
Inspect the Compressor Oil:
Regularly check the compressor oil level and condition. Low or degraded oil can lead to excessive wear on the compressor’s internal components. Follow the manufacturer's schedule for oil changes.
Check for Leaks:
Inspect refrigerant lines and seals for any signs of leakage. Leaking refrigerant can reduce cooling efficiency and cause compressor failure over time.
Ensure Proper Ventilation:
Make sure that the compressor is placed in a well-ventilated area to avoid overheating. Insufficient airflow can cause the motor to run hotter than normal, potentially leading to failure.
Test Motor and Compressor Performance:
Periodically check the compressor’s performance by monitoring its operating pressures and temperatures. Abnormal readings could indicate mechanical issues or electrical problems.
Inspect the Start/Run Capacitors:
Inspect the start and run capacitors for any signs of damage or wear. Faulty capacitors can prevent the compressor from starting or cause inefficient operation.
Ensure Proper Voltage:
Confirm that the compressor is receiving the correct voltage (208-230V, single-phase) to prevent electrical issues. Incorrect voltage can lead to motor failure or poor performance.
Schedule Regular Professional Servicing:
Have a qualified technician perform routine maintenance, including checking the refrigerant charge, pressure testing, and ensuring all components are functioning correctly.