Pioneer 36,000 BTU 18 SEER Ducted Central Split Air Conditioner Heat Pump System - DYR3036GMFI18R

The Pioneer ducted central air split units offer climate control for multiple rooms and areas, utilizing a network of air ducts (existing or field designed) using a single set of equipment. Pioneer’s durable ducted central air conditioner split systems work perfectly to for whole-house climate control. In this setting, a single set of equipment will properly heat and cool a large area with many rooms, under the same comfort settings.

Our ducted central air split units come in a variety of configurations, making it easy to find a model that meets your heating and cooling needs. 

  • Cooling capacity: 36,000 BTU/H with 18 SEER efficiency
  • Heating capacity: 36,000 BTU/H with 11 HSPF efficiency
  • Voltage: 208~230 V, 60 Hertz, 1 Ph
  • Central Ducted Air Conditioning & Heating System
  • Variable Speed DC Inverter Operation Mode
  • Includes 10 kW Electric Strip Heater w/ breaker
  • Indoor Unit (Downflow-capable) - DR036GHFD18HT2  
  • Outdoor Unit (Side-Discharge) - YH3036GHFD18R2
  • Electric Strip Heater (10 kW w/ breaker)
  • R410A Pre-Charged Outdoor Unit
  • Manufacturer Warranty
      Product Dimensions 37 3/8"W x 13 3/8"D x 33"H
      Cooling Capacity 36,000 BTU
      Heating Capacity 36,000 BTU
      Zone Capacity 1
      Low Ambient Unit -15F
      SEER 18
      Voltage Requires a minimum of 208~230 V, 60 Hertz, 1 Ph (please check your home meets this electrical requirement prior to purchase)
      Warranty 5 Years Parts
      Air Handler
      Product Dimensions 19 5/8"W x 21 5/8"D x 46 1/8"H
      Cooling Capacity 36,000 BTU
      Heating Capacity 36,000 BTU
      Coverage Area Up to 1,200 Square Feet
      Warranty 5 Years on Parts
      • 36,000 BTU Capacity: Perfect for medium to large homes or commercial spaces, providing effective cooling and heating for multiple zones or rooms.
      • 18 SEER Energy Efficiency: Delivers a balance of energy savings and reliable performance, helping to reduce energy bills while maintaining comfort.
      • Ducted Central System: Distributes conditioned air evenly throughout your home or business, ensuring consistent temperature control across all rooms.
      • Heat Pump Technology: Offers both heating and cooling in one unit, providing year-round comfort with minimal effort.
      • Quiet Operation: Designed for low noise levels, ensuring a peaceful environment without compromising performance.
      • Durable & Reliable: Made with high-quality components, this system is built for long-term use and minimal maintenance.
      • Flexible Installation: Ideal for spaces with existing ductwork or for new installations, making it a versatile solution for various setups.

      Q: What is the cooling capacity of the Pioneer 36,000 BTU Ducted Central Split system?
      A: This system provides 36,000 BTU of cooling power, ideal for medium to large residential or commercial spaces.

      Q: What is the SEER rating of the Pioneer 36,000 BTU Ducted Central Split system?
      A: It offers an 18 SEER rating, ensuring efficient operation while helping to reduce energy consumption.

      Q: Does the Pioneer Ducted Central Split system provide both cooling and heating?
      A: Yes, it works as both an air conditioner and heat pump, providing year-round comfort for both cooling and heating needs.

      Q: What are the main features of the Pioneer 36,000 BTU Ducted Central Split system?
      A: This system includes advanced inverter technology, quiet operation, reliable filtration, and a ducted air distribution system for consistent and efficient temperature control across large areas.

      Q: Is the Pioneer 36,000 BTU system easy to install?
      A: Yes, it is designed for professional installation with a central ducted setup, offering seamless integration into existing HVAC systems for efficient climate control.

      • Clean or Replace Filters: Inspect and clean the filters every 2-4 weeks to ensure proper airflow. Replace filters annually or if they are damaged or worn.
      • Clean the Coils: Clean the evaporator and condenser coils at least once a year to remove dirt and debris, ensuring optimal heat exchange and system efficiency.
      • Check Ductwork: Inspect the ductwork for leaks, damage, or blockages that can impede airflow. Seal leaks and clean ducts as necessary to improve system efficiency.
      • Inspect the Drain Line: Regularly check the condensate drain line and ensure it is clear to prevent water damage and clogs.
      • Monitor Refrigerant Levels: Ensure refrigerant levels are adequate. If you notice reduced cooling or heating performance, consult a professional for an inspection and recharge if necessary.
      • Clear the Outdoor Unit: Keep the outdoor unit free of debris like leaves and dirt to ensure proper airflow and prevent overheating.
      • Professional Annual Maintenance: Have a qualified technician inspect and service the system annually, checking refrigerant levels, cleaning components, and ensuring overall system efficiency.