At Pioneer Mini Split, we offer variable capacity ductless wall-mounted mini split systems, available with different efficiency ratings and in a variety of capacities for simple installation and great single-zone comfort. Our ductless mini split wall-mounted air conditioners and heat pumps come with a convenient remote controller conveys cooling, heating, dehumidification, and ventilation requests to the wall-mount ductless mini split system, while automatic air-sweeping louvers, automatically varying air flow, and capacity adjustments keep the zone at the ultimate comfort level. This results in minimal electrical consumption for a more efficient ductless wall air conditioner and heating system. Check out our selection of wall-mounted heating and cooling units today!
Optional
Performance Data | |
---|---|
Power Supply | 110~120V, 60Hz, 1Ph |
Cooling Rated Capacity | 12,000 BTU/h |
Cooling Capacity Range | 3,500~12,150 BTU/h |
Cooling SEER | 21.5 BTU/w |
Cooling EER | 12.5 BTU/w |
SEER2 | 22.7 |
Heating Rated Capacity | 12,000 BTU/h |
Heating Capacity Range | 4,600~12,904 BTU/h |
Heating HSPF | 11.5 BTU/w |
Refrigerant Type | R410a |
Suitable Area | 300~450 Sq.F |
Warranty | 5 years parts and compressor warranty |
Condenser | |
Sound Level | 52.5 dB(A) |
Breaker Needed | 20A (single-pole) |
Net Dimensions (WDH) | 30.2"W x 11.8" D x 21.7" H |
Carton Dimensions (WDH) | 34.8" W x 13.25" D x 24" H |
Net / Gross Weight | 66.8 / 72.3 Lbs |
Cool Mode - Outdoor Operating Temperature Range | 5° to 122°F |
Heat Mode - Outdoor Operating Temperature Range | -13° to 75°F |
Air Handler | |
Air Flow (Hi/Med/Lo) | 306 / 212 / 147 CFM |
Sound Level (Hi/Lo) | 36.0 / 23.0 dB(A) |
Net Dimensions (WDH) | 31.5" W x 7.3" D x 11.6" H |
Carton Dimensions (WDH) | 34.5" W x 11.25" D x 15" H |
Net / Gross Weight | 24 / 34.2 Lbs |
Q: What is the Pioneer 24,000 BTU 21 SEER Ductless Mini-Split Inverter++ Air Conditioner Heat Pump System?
A: This high-capacity mini-split system provides both cooling and heating with a 21 SEER rating. Equipped with Inverter++ technology, it ensures energy-efficient, quiet operation and precise temperature control. This version does not include an installation kit, offering flexibility in setup.
Q: How does Inverter++ technology enhance system performance?
A: Inverter++ technology adjusts the compressor speed to match temperature demand, improving energy efficiency, reducing noise, and maintaining a comfortable, consistent environment.
Q: What room size is this system suitable for?
A: This system is ideal for cooling and heating larger spaces, covering up to 1,000 sq. ft.
Q: Is it suitable for residential use?
A: Yes, it’s perfect for larger residential applications, providing effective climate control with minimal noise and energy consumption.
Q: Does it require professional installation?
A: Since this unit does not come with an installation kit, professional installation is recommended for optimal performance and reliability.
Clean the Air Filters Regularly: Clean the air filters every 1-2 months to maintain proper airflow and efficiency. Gently vacuum or rinse them with water to remove accumulated dust and dirt. Allow the filters to dry completely before reinserting them into the unit.
Inspect and Clean the Coils: Dirty evaporator and condenser coils can reduce system efficiency and performance. Every 6 months, inspect the coils and gently clean them with a soft brush or compressed air to remove dirt and debris.
Check for Ice or Frost Buildup: If you notice ice or frost forming on the evaporator coils, it could indicate restricted airflow or a refrigerant issue. Turn off the unit and let it thaw before checking for potential airflow blockages or scheduling a professional inspection.
Ensure Proper Drainage: The condensate drain should be clear to prevent water damage and maintain proper cooling and heating. Regularly inspect and clean the drainage system, using a wet/dry vacuum if necessary to clear clogs and ensure efficient drainage.
Monitor Refrigerant Levels: If the system is not cooling or heating properly, low refrigerant levels could be the cause. Have a certified technician check the refrigerant level annually, and repair any leaks if necessary to prevent further issues.
Check the Outdoor Unit: Ensure that the outdoor condenser unit is free of debris, such as leaves, dirt, or branches, that can obstruct airflow. A clean outdoor unit will run more efficiently and prevent overheating.
Inspect the Refrigerant Lines: Examine the refrigerant lines for any signs of wear or damage, including insulation issues. Properly insulated lines help prevent energy loss, so replace damaged insulation to maintain system efficiency.
Watch for Unusual Noises or Behavior: Pay attention to any strange sounds (e.g., grinding, buzzing, or rattling) or performance issues, such as poor cooling or heating. Unusual noises or irregular behavior may signal a mechanical issue that needs professional attention.
Schedule Annual Professional Maintenance: To keep your Pioneer 24,000 BTU Ductless Mini-Split in optimal condition, schedule professional maintenance once a year. A technician can inspect all components, check refrigerant levels, clean the system, and make sure everything is working as it should.
Thanks for subscribing!
This email has been registered!
At Pioneer Mini Split, we offer variable capacity ductless wall-mounted mini split systems, available with different efficiency ratings and in a variety of capacities for simple installation and great single-zone comfort. Our ductless mini split wall-mounted air conditioners and heat pumps come with a convenient remote controller conveys cooling, heating, dehumidification, and ventilation requests to the wall-mount ductless mini split system, while automatic air-sweeping louvers, automatically varying air flow, and capacity adjustments keep the zone at the ultimate comfort level. This results in minimal electrical consumption for a more efficient ductless wall air conditioner and heating system. Check out our selection of wall-mounted heating and cooling units today!
Optional
Performance Data | |
---|---|
Power Supply | 110~120V, 60Hz, 1Ph |
Cooling Rated Capacity | 12,000 BTU/h |
Cooling Capacity Range | 3,500~12,150 BTU/h |
Cooling SEER | 21.5 BTU/w |
Cooling EER | 12.5 BTU/w |
SEER2 | 22.7 |
Heating Rated Capacity | 12,000 BTU/h |
Heating Capacity Range | 4,600~12,904 BTU/h |
Heating HSPF | 11.5 BTU/w |
Refrigerant Type | R410a |
Suitable Area | 300~450 Sq.F |
Warranty | 5 years parts and compressor warranty |
Condenser | |
Sound Level | 52.5 dB(A) |
Breaker Needed | 20A (single-pole) |
Net Dimensions (WDH) | 30.2"W x 11.8" D x 21.7" H |
Carton Dimensions (WDH) | 34.8" W x 13.25" D x 24" H |
Net / Gross Weight | 66.8 / 72.3 Lbs |
Cool Mode - Outdoor Operating Temperature Range | 5° to 122°F |
Heat Mode - Outdoor Operating Temperature Range | -13° to 75°F |
Air Handler | |
Air Flow (Hi/Med/Lo) | 306 / 212 / 147 CFM |
Sound Level (Hi/Lo) | 36.0 / 23.0 dB(A) |
Net Dimensions (WDH) | 31.5" W x 7.3" D x 11.6" H |
Carton Dimensions (WDH) | 34.5" W x 11.25" D x 15" H |
Net / Gross Weight | 24 / 34.2 Lbs |
Q: What is the Pioneer 24,000 BTU 21 SEER Ductless Mini-Split Inverter++ Air Conditioner Heat Pump System?
A: This high-capacity mini-split system provides both cooling and heating with a 21 SEER rating. Equipped with Inverter++ technology, it ensures energy-efficient, quiet operation and precise temperature control. This version does not include an installation kit, offering flexibility in setup.
Q: How does Inverter++ technology enhance system performance?
A: Inverter++ technology adjusts the compressor speed to match temperature demand, improving energy efficiency, reducing noise, and maintaining a comfortable, consistent environment.
Q: What room size is this system suitable for?
A: This system is ideal for cooling and heating larger spaces, covering up to 1,000 sq. ft.
Q: Is it suitable for residential use?
A: Yes, it’s perfect for larger residential applications, providing effective climate control with minimal noise and energy consumption.
Q: Does it require professional installation?
A: Since this unit does not come with an installation kit, professional installation is recommended for optimal performance and reliability.
Clean the Air Filters Regularly: Clean the air filters every 1-2 months to maintain proper airflow and efficiency. Gently vacuum or rinse them with water to remove accumulated dust and dirt. Allow the filters to dry completely before reinserting them into the unit.
Inspect and Clean the Coils: Dirty evaporator and condenser coils can reduce system efficiency and performance. Every 6 months, inspect the coils and gently clean them with a soft brush or compressed air to remove dirt and debris.
Check for Ice or Frost Buildup: If you notice ice or frost forming on the evaporator coils, it could indicate restricted airflow or a refrigerant issue. Turn off the unit and let it thaw before checking for potential airflow blockages or scheduling a professional inspection.
Ensure Proper Drainage: The condensate drain should be clear to prevent water damage and maintain proper cooling and heating. Regularly inspect and clean the drainage system, using a wet/dry vacuum if necessary to clear clogs and ensure efficient drainage.
Monitor Refrigerant Levels: If the system is not cooling or heating properly, low refrigerant levels could be the cause. Have a certified technician check the refrigerant level annually, and repair any leaks if necessary to prevent further issues.
Check the Outdoor Unit: Ensure that the outdoor condenser unit is free of debris, such as leaves, dirt, or branches, that can obstruct airflow. A clean outdoor unit will run more efficiently and prevent overheating.
Inspect the Refrigerant Lines: Examine the refrigerant lines for any signs of wear or damage, including insulation issues. Properly insulated lines help prevent energy loss, so replace damaged insulation to maintain system efficiency.
Watch for Unusual Noises or Behavior: Pay attention to any strange sounds (e.g., grinding, buzzing, or rattling) or performance issues, such as poor cooling or heating. Unusual noises or irregular behavior may signal a mechanical issue that needs professional attention.
Schedule Annual Professional Maintenance: To keep your Pioneer 24,000 BTU Ductless Mini-Split in optimal condition, schedule professional maintenance once a year. A technician can inspect all components, check refrigerant levels, clean the system, and make sure everything is working as it should.