Get In Touch
Get In Touch +1 (888) 575-2099
At Pioneer Mini Split, we offer variable capacity ductless wall-mounted mini split systems, available with different efficiency ratings and in a variety of capacities for simple installation and great single-zone comfort. Our ductless mini split wall-mounted air conditioners and heat pumps come with a convenient remote controller conveys cooling, heating, dehumidification, and ventilation requests to the wall-mount ductless mini split system, while automatic air-sweeping louvers, automatically varying air flow, and capacity adjustments keep the zone at the ultimate comfort level. This results in minimal electrical consumption for a more efficient ductless wall air conditioner and heating system. Check out our selection of wall-mounted heating and cooling units today!
Optional
Performance Data | |
---|---|
Power Supply | 208~230V, 60Hz, 1Ph |
Cooling Rated Capacity | 24,000 BTU/h |
Cooling Capacity Range | 9,200~25,000 BTU/h |
Cooling SEER | 21 BTU/w |
Cooling EER | 12.5 BTU/w |
SEER2 | 21 |
Heating Rated Capacity | 26,000 BTU/h |
Heating Capacity Range | 10,350~26,410 BTU/h |
Heating HSPF | 10.0 BTU/w |
Heating COP | 3.05 W/W |
Refrigerant Type | R410a |
Suitable Area | 650~900 Sq.F |
Warranty | 5 years parts and compressor warranty |
Condenser | |
Sound Level | 61.0 dB(A) |
Breaker Needed | 25A (double-pole) |
Net Dimensions (WDH) | 37.2"W x 16.2" D x 31.8" H |
Carton Dimensions (WDH) | 42.8" W x 19.6" D x 34.8" H |
Net / Gross Weight | 124.8 / 134.9 Lbs |
Cool Mode - Outdoor Operating Temperature Range | 5° to 122°F |
Heat Mode - Outdoor Operating Temperature Range | -13° to 75°F |
Air Handler | |
Air Flow (Hi/Med/Lo) | 618 / 471 / 324 CFM |
Sound Level (Hi/Med/Lo) | 47.5 / 42.0 / 32.0 dB(A) |
Net Dimensions (WDH) | 42.5" W x 8.8" D x 13.2" H |
Carton Dimensions (WDH) | 45.5" W x 12.3" D x 16.3" H |
Net / Gross Weight | 30.2 / 37.9 Lbs |
Q: What is the Pioneer 12,000 BTU 22 SEER Ductless Mini-Split Inverter++ Air Conditioner Heat Pump System?
A: This mini-split system provides both cooling and heating with a 22 SEER rating. Featuring Inverter++ technology, it ensures energy-efficient performance, quiet operation, and precise temperature control. It comes with 25 ft. line sets for flexible installation.
Q: How does Inverter++ technology improve system performance?
A: Inverter++ technology adjusts the compressor speed based on temperature demand, leading to better energy efficiency, quieter operation, and consistent comfort.
Q: What size room is this system suitable for?
A: This system is ideal for rooms up to 450 sq. ft., providing efficient cooling and heating.
Q: Is it suitable for residential use?
A: Yes, it’s perfect for residential applications, offering reliable comfort with minimal noise and energy savings.
Q: Does it require professional installation?
A: While the system includes 25 ft. line sets for flexible installation, professional installation is recommended for optimal performance and long-term reliability.
Regular Filter Cleaning: Clean the air filters every 1-2 months to ensure optimal airflow and prevent dust and debris buildup. Simply remove the filters and wash them with lukewarm water and mild detergent. Allow them to dry completely before reinstalling.
Inspect for Ice Buildup: Check for signs of ice forming on the indoor unit's evaporator coil. Ice buildup can reduce efficiency and damage components. If ice appears, turn off the unit and inspect airflow or refrigerant levels, and contact a professional for repairs if necessary.
Clean the Coils and Fins: Dust and debris on the condenser and evaporator coils can restrict airflow and reduce efficiency. Use a soft brush or compressed air to clean both coils every 6 months or more often if needed. Ensure no dirt or obstructions block the fins of the unit.
Maintain the Drain Line: Periodically check the condensate drain line to ensure it is clear of blockages. A clogged drain can cause water damage and reduce performance. Use a wet/dry vacuum to clean out any buildup in the line if necessary.
Check Refrigerant Levels: Low refrigerant levels can reduce the cooling and heating performance. A licensed technician should check the refrigerant levels during routine maintenance to ensure optimal performance. If the refrigerant is low, the system may have a leak that needs to be repaired.
Inspect Outdoor Unit: Ensure the outdoor condenser unit is free from obstructions such as leaves, dirt, or debris. Clear any clutter around the unit, leaving at least 2-3 feet of space for proper airflow. Inspect the unit for any visible damage or signs of wear.
Ensure Proper Insulation: Check the insulation on the refrigerant lines for signs of wear or deterioration. Replace any damaged insulation to reduce energy loss and maintain system efficiency.
Monitor System Performance: Pay attention to the unit’s performance throughout the year. If you notice unusual noises, poor cooling or heating output, or uneven temperature distribution, it's best to consult a professional technician for diagnostics.
Schedule Professional Maintenance: For optimal system efficiency and longevity, have your Pioneer mini-split unit serviced by a professional technician annually. A technician will clean the internal components, check refrigerant levels, and inspect for any signs of potential issues before they escalate.