Skip to product information
1 of 10

Tuttnauer

Tuttnauer 2540MK Kwiklave Autoclave - MFI-TTN-2540MK

Tuttnauer 2540MK Kwiklave Autoclave - MFI-TTN-2540MK

1 Review

5% Sale

Only left!

image

Free Delivary

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $3,637.00 Sale price $3,455.99
Shipping calculated at checkout.

Quintity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Tuttnauer 2540MK Kwiklave Autoclave - MFI-TTN-2540MK

The Tuttnauer 2540MK Kwiklave Autoclave offers all of the dependable features of the Tuttnauer M Series Manual Autoclaves, with the added benefit of reducing the total heat up time. This manual, quick-cycle model is the perfect choice for quick instrument turn-around or a high volume office. Speed and reliability are accomplished without sacrificing load size.

All certified autoclaves include a power cable and new PM (preventative maintenance) kit installed which includes a new gasket and filters. We also perform a complete calibration to manufacturer specifications, spore test, and complete flush of the system.

Features
  • Automatic shut-off at the end of both the sterilization and dry cycles.
  • A long life electro polished stainless steel chamber and door made to last.
  • Double safety locking device prevents door from opening while chamber is pressurized.
  • Drain valve is conveniently located in the front, allowing for quick and easy draining of water reservoir.
  • Dual safety thermostat and automatic shut-off to protect against overheating.
  • Designed with the operator in mind, the colorful control panel is intuitive and easy to use.
  • International certifications.
Specifications
Chamber Dimensions 10" x 19" (254 mm x 475 mm)
Chamber Volume 6 gallons (23 L)
Overall Dimensions 21.5" (D) x 20" (W) x 14.4" (H) (545 mm x 510 mm x 365 mm)
Standard Cassette Capacity 3 full and 3 half
Standard Full Size Cassette 8" x 11"
Standard Half Size Cassette 8" x 5.5"
Tray Dimensions 16.3" (D) x 6.7" (W) x 0.8" (H) (415 mm x 170 mm x 20 mm)
Number of Trays 4
Standard Unwrapped Cycle Time Cold: 21 minutes, Hot: 11 minutes
Voltage 230 V
Frequency 50/60 Hz
Power 2200 W
Current 10 A
Shipping Weight 85 lb (39 kg)
Standards ASME, UL/EN 61010-1, FDA, ISO 13485:2003, ISO 9001:2000
Conditions
  • #MFI-TTN-2540MK: Certified Refurbished.
  • #2540MK: Factory New.
Accessories

The following accessories are compatible and commonly purchased with the 2540MK Kwiklave Autoclave:

  • Chamber Brite Powdered Autoclave Cleaner:
    • #CB0010-1: Box (10 Packets).
    • #CB0010: Case (120 Packets).
  • Clean & Simple Ultrasonic/Enzymatic Tablets:
    • #CS0144-1: Box of 144.
    • #CS0064: Case of 768.
    • #CS0144: Case of 1728.
  • Clean & Simple Ultrasonic Cleaner:
    • #CSU1: 0.85 gallon.
    • #CSU1BK: 0.85 gallon with Basket.
    • #CSU1H: 0.85 gallon with Heater.
    • #CSU1HBK: 0.85 gallon with Heater and Basket.
    • #CSU3: 3.25 gallon.
    • #CSU3BK: 3.25 gallon with Basket.
    • #CSU3H: 3.25 gallon with Heater.
    • #CSU3HBK: 3.25 gallon with Heater and Basket.
    • #CSU6: 6.5 gallon.
    • #CSU6BK: 6.5 gallon with Basket.
    • #CSU6H: 6.5 gallon with Heater.
    • #CSU6HBK: 6.5 gallon with Heater and Basket.
  • #DS1000: Steam Distiller Purification System.
Literature

Tuttnauer Table Top Line Autoclaves and Accessories Catalog

Tuttnauer Manual Autoclaves - Weekly Cleaning and Maintenance Instructions

Tuttnauer Operation And Maintenance Manual - Tabletop Autoclaves

What Our Experts Think
  • Quick & Efficient – Kwiklave technology ensures fast sterilization cycles, providing reliable results with minimal wait time.
  • Compact Design – Ideal for smaller spaces, offering high-capacity sterilization without taking up too much room.
  • User-Friendly – Features simple controls for easy operation, making it suitable for both new and experienced users.
  • Durable & Reliable – Built with high-quality materials to withstand constant use and ensure long-term performance.
  • Versatile Use – Perfect for medical, dental, and veterinary practices that require quick, effective sterilization.
Q&A

Q: What is the purpose of the Tuttnauer 2540MK Kwiklave Autoclave?
A: The Tuttnauer 2540MK Kwiklave Autoclave is designed for fast and efficient sterilization of instruments in medical, dental, and laboratory environments, ensuring that tools are properly sterilized for safe use.

Q: How quickly does the Kwiklave Autoclave sterilize items?
A: The Tuttnauer 2540MK Kwiklave features rapid sterilization cycles, providing fast turnaround times for sterilizing smaller loads, making it ideal for busy practices needing quick access to sterilized tools.

Q: Is the Kwiklave Autoclave easy to use?
A: Yes, the Tuttnauer 2540MK is user-friendly, with simple controls and clear display options to make the sterilization process efficient and straightforward.

Q: What is the capacity of the Tuttnauer 2540MK Kwiklave Autoclave?
A: The 2540MK model has a chamber size that can accommodate smaller loads, typically around 4 liters, making it suitable for clinics or offices that need compact sterilization solutions.

Q: What safety features does the Tuttnauer 2540MK include?
A: The autoclave includes multiple safety features such as over-temperature protection, door safety locks during operation, and automatic shut-off for enhanced user protection.

Q: How should I maintain the Tuttnauer 2540MK Kwiklave Autoclave?
A: Regular cleaning, periodic maintenance checks, and using distilled water will help maintain the performance and longevity of the autoclave, ensuring reliable sterilization results.

Maintenance Tips
  • Clean After Each Use: Clean the chamber and exterior with a damp cloth after each use to remove any residue or moisture. Avoid abrasive cleaners.
  • Inspect Seals: Check the door gasket and seals for wear or damage regularly. Replace them if cracked or worn to maintain proper pressure.
  • Calibrate Sterilization Parameters: Regularly check and calibrate temperature and pressure readings to ensure accurate sterilization performance.
  • Empty the Drain: After each cycle, ensure that the drain valve is opened to release any remaining water and avoid buildup.
  • Check and Replace Filters: Inspect and replace water filters as needed to maintain water quality and prevent mineral buildup.
  • Inspect the Chamber: Periodically check the interior chamber for rust, corrosion, or debris. Clean the chamber with non-corrosive solutions if necessary.
  • Test Safety Features: Regularly test safety features such as pressure relief valves and automatic shut-off mechanisms to ensure they are functioning correctly.
  • Lubricate Door Mechanism: Apply a small amount of lubricant to the door latch and hinges to ensure smooth operation.
  • Service Annually: Schedule annual servicing by a professional technician to check the mechanical and electrical components of the autoclave.