Skip to product information
1 of 10

Tuttnauer

Tuttnauer 4472 Autoclave - TTN-4472-1V

Tuttnauer 4472 Autoclave - TTN-4472-1V

1 Review

5% Sale

Only left!

image

Free Delivary

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $43,695.00 Sale price $41,510.99
Shipping calculated at checkout.

Quintity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Tuttnauer 4472 Autoclave - TTN-4472-1V

The Tuttnauer 4472 Autoclave (#4472-1V) has a single, automatic vertical sliding door, with Pre/Post Vacuum Class B features. This model is designed to be recessed into the wall by default, but a stainless steel cabinet for standalone use is available (see Accessories). 

Features
  • Made from stainless steel, including steel piping and connectors to avoid corrosion.
  • Up to 14 programs can be chosen for sterilizing.
  • User-friendly touch control panel.
  • Suitable for hospitals and laboratories.
Specifications
Weight 1100 lbs (499 kg)
Chamber Dimensions 16" x 16" x 28"
Chamber Volume 4 Cubic Feet (120 Liters)
Door Type Automatic Vertical Sliding Door
Steam Options House Steam Standard (Optional Integral Steam Generator)
Mounting Options Cabinet Enclosed or Recessed Through Wall (Left or Right Service)
Class Type Class B, Pre/Post Vacuum Standard
Loading Equipment Rack & 2 Shelves Standard (Optional Loading Cart & Transfer Carriage)
External Dimensions 31" x 76" x 46"
Plant Steam Supply Pipe Size 3/4" NPT
Plant Steam Supply Flow Rate 48 Lbs/Hr Peak - 17 Lbs/Cycle Avg.
Building Drain 2" ODT
Compressed Air Requirements 75-95 PSIG Dynamic, 3.5 SCFM, 3/8” NPT
Electrical Requirements (Control System) 1-Phase, 120v, 50/60Hz, 20A

Accessories
  • #RS-4472: Tuttnauer 4472 Rack and Two Shelves.
  • #P-GEN0016: Tuttnauer 4472 Steam Generator with Automatic Blow Down.
  • #CAB-4472-1V: Tuttnauer 4472 Stainless Steel Cabinet.
  • #LC-4472: Tuttnauer 4472 Loading Cart.
  • #TC-4472: Tuttnauer 4472 Transfer Carriage.
  • #1760440: Tuttnauer 4472 Air Compressor.
  • #LC2PC40GVFSO2SS-01: Tuttnauer Reverse Osmosis Water Treatment System.
Literature

Tuttnauer Laboratory and Scientific Line Horizontal Steam Sterilizers Brochure

Tuttnauer 44 and 55 Compact Sterilizer Series Specifications

What Our Experts Think
  • Large Capacity – With a 17" chamber, it can handle larger loads, making it ideal for high-volume medical, dental, or laboratory use.
  • Automatic Cycle Control – Provides fully automated sterilization cycles, ensuring consistent, reliable results every time.
  • Efficient & Fast – Delivers quick cycle times, reducing wait times and maximizing productivity.
  • Durable & Reliable – Built with heavy-duty materials for long-lasting performance in demanding environments.
  • User-Friendly Interface – Simple controls and an intuitive design for easy operation and monitoring of the sterilization process.
Q&A

Q: What are the key features of the Tuttnauer 4472 Autoclave?
A: The Tuttnauer 4472 Autoclave features a large 17" x 30" chamber, ideal for sterilizing larger quantities of medical, dental, or laboratory instruments. It includes automatic functions for ease of use, efficient steam sterilization, and a reliable control system with a digital display for monitoring cycles.

Q: What is the chamber size of the Tuttnauer 4472 Autoclave?
A: The autoclave has a spacious chamber size of 17" x 30", allowing for the sterilization of a wide range of instruments.

Q: Is the Tuttnauer 4472 suitable for medical or dental offices?
A: Yes, the Tuttnauer 4472 is designed for use in medical, dental, and laboratory environments where large quantities of tools need to be sterilized.

Q: Does this autoclave have automatic controls?
A: Yes, the Tuttnauer 4472 features automatic cycles, including a digital display for easy monitoring and control of sterilization processes.

Q: What type of sterilization method does this autoclave use?
A: The Tuttnauer 4472 uses steam sterilization, a highly effective method for eliminating bacteria, viruses, and other pathogens from instruments.

Q: What safety features does the Tuttnauer 4472 include?
A: The Tuttnauer 4472 includes automatic shut-off and pressure relief valves to ensure safety during operation and after sterilization.

Q: How do I maintain the Tuttnauer 4472 Autoclave?
A: Regular maintenance includes cleaning the chamber, checking the door gasket, testing the sterilization cycles, and ensuring proper pressure and temperature readings for reliable performance.

Maintenance Tips
  • Clean the Chamber: After each use, wipe down the interior chamber to remove moisture and debris to prevent buildup.
  • Inspect the Door Seal: Regularly check the door gasket for wear and replace it if it shows any signs of damage or deterioration.
  • Drain Water Reservoir: Empty the water reservoir after every cycle to avoid the growth of bacteria and mineral deposits.
  • Descale the Chamber: Periodically clean and descale the chamber to prevent mineral buildup, especially if you use hard water.
  • Check the Pressure Relief Valve: Ensure the pressure relief valve is functioning correctly and is free from obstructions to maintain safe operation.
  • Lubricate the Door Mechanism: Apply lubricant to the door hinges and locking mechanism to ensure smooth operation.
  • Inspect Safety Features: Test the pressure, temperature, and safety features regularly to ensure proper function.
  • Replace Filters: If your autoclave model has filters, inspect and replace them as needed to maintain optimal performance.
  • Schedule Professional Servicing: Have the autoclave inspected annually by a certified technician to ensure it’s functioning efficiently and safely.