The Tuttnauer AmeriWater RO Water Filtration System includes quick-connect ports for feed, product, and reject water, a user-friendly digital microprocessor with TDS monitoring, adjustable limits, and fault/status displays, along with tank full contacts for smart control.
The Tuttnauer AmeriWater RO Water Filtration System is a high-performance water treatment system designed to deliver low-conductivity water for the final rinse and disinfection cycles of tabletop, freestanding, and under-counter washers. With a production capacity of 150 gallons per day (GPD), the system features a reverse osmosis (RO) unit paired with a choice of 4, 9, or 14-gallon pressurized storage tanks. Its versatile design allows for wall mounting or installation under a standard counter sink, making it an ideal solution for spaces requiring compact and efficient water purification.
The RO Water Filtration System is engineered for reliability and ease of maintenance, featuring high rejection TFC membranes and dual 10-micron carbon block prefilters for superior water quality. A durable powder-coated aluminum frame, integrated booster pump, and liquid-filled pressure gauges enhance performance and durability. Designed for end-user installation and optimal serviceability, the SRO150 Series is a dependable solution for delivering purified water essential for critical cleaning and disinfection processes.
Production Capacity | 150 GPD |
---|---|
Feedwater Temperature | 50 to 90 degrees F (Ideal is 77 degrees F) |
Nominal Rejection | 95 to 98% |
Feedwater | Potable Drinking Water Standards |
Feedwater Pressure Min / Max | 30 / 80 PSI |
Minimum Feedwater Flow Rate | 1 GPM |
Electrical | 115V, 50/60 Hz, 1 Ph, 3 Amps, Standard 3 Prong Plug |
Weight Without Water (RO) | 40 lb |
Dimensions (RO) | 11.5" W x 16" D x 19" H |
Â
Models | #00SRO150-4 | #00SRO150-9 | #00SRO150-14 |
---|---|---|---|
Storage Tank Size | 4 Gallons | 9 Gallons | 14 Gallons |
Weight Without Water (Tank) | 8 lb | 15 lb | 24 lb |
Dimensions (Tank) | 11" W x 11" D x 15" H | 13" W x 13" D x 20" H | 16" W x 16" D x 24" H |
Tuttnauer AmeriWater SRO150 Series Brochure
Q: What is the Tuttnauer AmeriWater RO Water Filtration System?
A: The Tuttnauer AmeriWater RO Water Filtration System is a high-performance reverse osmosis (RO) water purification system designed to provide clean, pure water for laboratory, medical, and industrial use.
Q: What does the AmeriWater RO Water Filtration System do?
A: The system uses reverse osmosis technology to remove impurities, contaminants, and harmful substances from water, providing ultra-pure water for various applications, including autoclaving, laboratory testing, and medical equipment sterilization.
Q: What is the capacity of the Tuttnauer AmeriWater RO Water Filtration System?
A: The system is designed to handle up to 150 gallons per day (GPD), making it suitable for moderate to high-volume water purification needs in laboratories or healthcare settings.
Q: How does the Tuttnauer AmeriWater RO Water Filtration System work?
A: The RO system uses a multi-stage filtration process, including sediment filters, carbon filters, and reverse osmosis membranes, to remove dissolved solids, bacteria, viruses, and other contaminants from the water.
Q: What are the key benefits of using the Tuttnauer AmeriWater RO Water Filtration System?
A: The system provides purified water with reduced total dissolved solids (TDS), ensuring water quality for sensitive applications. It is efficient, easy to maintain, and designed to operate continuously, providing a reliable water source.
Q: Is the Tuttnauer AmeriWater RO Water Filtration System easy to install?
A: Yes, the system comes with clear installation instructions and is designed for easy integration into existing water lines with minimal setup requirements.
Q: What maintenance is required for the Tuttnauer AmeriWater RO Water Filtration System?
A: Routine maintenance includes replacing the pre-filters, checking the RO membranes, and ensuring the system is functioning properly. The maintenance schedule is user-friendly, and a service guide is available for easy reference.
Q: Can the Tuttnauer AmeriWater RO Water Filtration System be used in a medical setting?
A: Yes, this system is ideal for medical and laboratory environments, where high-quality water is necessary for autoclaving, dialysis, and other sensitive procedures.
Q: How long does the Tuttnauer AmeriWater RO Water Filtration System last?
A: With proper maintenance, the system can last for many years. The RO membranes typically need replacement every 2-3 years, depending on usage and water quality.
Q: Who is the Tuttnauer AmeriWater RO Water Filtration System ideal for?
A: This system is perfect for laboratories, healthcare facilities, research institutions, and industries that require high-purity water for operations like autoclaving, cleaning, and analysis.
Regularly Replace Filters: Change the pre-filters, post-filters, and RO membrane as recommended by the manufacturer. Typically, pre-filters should be replaced every 6 months, and the RO membrane should be replaced every 2-3 years, depending on usage and water quality.
Monitor Water Pressure: Ensure the incoming water pressure is within the system’s specified range (typically 40-80 psi). Low water pressure can reduce the system’s effectiveness, while high pressure may cause damage.
Check for Leaks: Periodically inspect the system, including hoses, fittings, and connections, for any signs of leaks. Address any issues immediately to prevent water damage or decreased performance.
Clean the RO Membrane: Every few months, clean the RO membrane according to the manufacturer's instructions. This helps maintain optimal filtration performance and prevents clogging.
Sanitize the System: At least once a year, sanitize the entire filtration system. This process helps prevent bacterial growth and ensures the system provides clean, purified water.
Monitor Water Quality: Regularly test the water output for total dissolved solids (TDS) to ensure the system is properly filtering contaminants. Replace the RO membrane if the TDS levels are higher than expected.
Check the Flow Rate: Ensure the system is producing water at the correct flow rate. A significant reduction in flow rate may indicate a clogged filter or membrane that needs replacing.
Drain System Regularly: Ensure the system’s drain is not clogged and is draining properly. A blocked drain could impact the overall system performance.
Inspect the System for Scale Buildup: In areas with hard water, mineral deposits can build up on the filters and membrane. Use a descaling solution to remove any deposits and keep the system functioning properly.
Annual Professional Maintenance: Schedule a professional inspection and service annually to ensure the RO system continues to perform optimally, and to identify any potential issues before they arise.